Datasets:
Bio-Pulse Physiological Telemetry Pack — Schema
One row = one physiological event sequence, end-to-end. All records share the same seven top-level fields.
Schema version: 1.0.0-bio-pulse-sample
Top-level fields
schema_version — string
Schema identifier. Constant within a sample release. Used to detect pack version drift.
event — struct
Identifier fields and the overall clinical outcome for the sequence.
| Field | Type | Notes |
|---|---|---|
id |
string | Stable episode identifier, e.g., BIOPULSE-100000. |
trace_id |
string (UUID) | Cross-links telemetry steps within the sequence. |
timestamp |
string (ISO-8601) | Episode start time. |
criticality |
string | low, medium, high, life_threatening. |
outcome |
string | patient_stabilized, intervention_successful, morbidity_risk_detected. |
confidence |
double | 0–1. Confidence of the outcome label. |
patient_context — struct
Synthetic patient archetype and baseline risk factors.
| Field | Type | Notes |
|---|---|---|
phenotype |
string | One of: pediatric_asthmatic, active_longevity, high_stress_corporate, sedentary_diabetic, geriatric_frailty. |
age_group |
string | 18-30, 31-50, 51-70, 70+. |
existing_conditions |
list | Conditions carried by the synthetic patient (e.g., asthma, type-2-diabetes). |
medical_logic — struct
Clinical scenario driving the sequence and the biomarkers being tracked.
| Field | Type | Notes |
|---|---|---|
diagnostic_class |
string | Drug_Interaction_Toxicity, Septic_Shock_Cascade, Nocturnal_Hypoglycemia. |
causal_chain |
list | Ordered causal event labels (e.g., MEDICATION_INGESTION_A, LIVER_ENZYME_DRIFT_SIMULATED, ARRHYTHMIA_DETECTION). |
prediction_window_minutes |
int | Minutes of lead time available before the terminal event. |
tracked_biomarkers |
list | Which biomarkers are reported in vitals_telemetry.vitals (e.g., glucose_mgdl, heart_rate_bpm, qt_interval_ms). |
vitals_telemetry — list
Ordered sensor readings for the episode. One struct per reading.
Reading struct:
| Field | Type | Notes |
|---|---|---|
timestamp |
string (ISO-8601) | Reading timestamp. |
sensor_id |
string | Synthetic sensor serial (e.g., SENS-6ACEC5). |
sensor_asset |
string | One of: CGM_Sensor, Smart_Watch_V3, O2_Ring, Neural_Patch_V2. |
event_name |
string | Label for what happened at this reading (matches one item in medical_logic.causal_chain). |
patient_id |
string | Synthetic patient identifier (e.g., PAT-D884ED0A). Not real. |
vitals.hr |
int | Heart rate (bpm). |
vitals.glucose |
double | Blood glucose (mg/dL). |
vitals.spo2 |
int | Peripheral oxygen saturation (%). |
vitals.temp_c |
double | Body temperature (°C). |
vitals.cortisol_ugdl |
double | Cortisol (µg/dL). |
vitals.systolic_bp |
int | Systolic blood pressure (mmHg). |
vitals.qt_interval_ms |
int | QT interval (ms). |
detection_logic — struct
Anomaly-signature metadata describing why this sequence is flagged.
| Field | Type | Notes |
|---|---|---|
signature |
string | Human-readable signature name (e.g., Predictive Drug_Interaction_Toxicity for pediatric_asthmatic). |
anomaly_score |
double | 0–1. Higher = more anomalous. |
baseline_deviation |
string | Short English description of the deviation pattern. |
simulation — struct
Simulation engine provenance.
| Field | Type | Notes |
|---|---|---|
synthetic |
bool | Always true. |
model |
string | Simulation engine label (bio_pulse_sim_v1 in this sample). |
fidelity |
string | Clinical_Grade. |
target_diagnoses |
list | Diagnoses this engine can produce (e.g., Hypoglycemic_Event, Septic_Shock). |
Distribution of this sample
- 10,000 sequences total.
- Criticality: balanced across
low/medium/high/life_threatening(~2,500 each). - Diagnostic class: balanced across 3 classes (~3,300 each).
- Phenotype: balanced across 5 archetypes (~2,000 each).
- Age group: skewed toward
70+(~3,200) to reflect chronic-care monitoring use cases. - Simulation engine label constant (
bio_pulse_sim_v1) after sanitization.
Sanitization notes
- Internal identifier prefix (
SIMA-V4-BIO-*) has been normalized toBIOPULSE-*. - Internal engine code name has been normalized to
bio_pulse_sim_v1. - Wearable device name previously labeled
Neural_Link_Betahas been renamed toNeural_Patch_V2to avoid collision with an unrelated company trademark. - No real patient IDs, names, clinic names, device serials, or health records are present. All identifiers are synthetic.
- Dataset is HIPAA-safe by construction: no covered data is present.
Relationship to the full pack
The production pack scales to 1M+ sequences with wider phenotype coverage, additional diagnostic classes (atrial fibrillation, asthma exacerbation, hypertensive crisis, post-op recovery, stroke precursors), richer biomarker panels, device-specific fidelity variants, longer causal chains, and FHIR-aligned delivery. See the pack card for commercial access.