Image-to-Text
English
custom
ocr
document-ai
information-extraction
key-information-extraction
nameplate
nameplate-ocr
equipment-nameplate
data-center
data-centre
datacenter
mission-critical
mep
electrical
mechanical
equipment-schedule
schedule-verification
asset-register
commissioning
quality-assurance
ups
pdu
switchgear
generator
ats
transformer
busway
battery
crah
crac
chiller
cooling
server-rack
construction
aec
edge-ai
on-device
privacy-preserving
tesseract
browser
Eval Results (legacy)
Download sample_plates.json from constructelligence/data-centre-nameplates: direct link, hf CLI and curl.
- Browser
- Download file 2.99 kB
-
https://huggingface.co/constructelligence/data-centre-nameplates/resolve/main/sample_plates.json
- Command line
-
hf download hf://constructelligence/data-centre-nameplates/sample_plates.json
-
curl -L -o sample_plates.json https://huggingface.co/constructelligence/data-centre-nameplates/resolve/main/sample_plates.json
2.99 kB
| { | |
| "note": "Fictional sample plates. UPS-1A matches schedule tag UPS-1A; the 415 V UPS is the same family but a different voltage variant, so it is flagged on model and voltage. The switchboard and the IT gear are not on the sample schedule, showing wider equipment recognition and the server-rack fields (Rack U, Form factor, Power W, Rack load, Outlet mix, Port speed, Ports).", | |
| "plates": [ | |
| { | |
| "id": "ups-match", | |
| "type": "ups", | |
| "expect_tag": "UPS-1A", | |
| "lines": [ | |
| "NORTHLINE POWER SYSTEMS", | |
| "UNINTERRUPTIBLE POWER SUPPLY", | |
| "MODEL NO: NPX-750-480", | |
| "SERIAL NO: NL26A01937", | |
| "INPUT: 480Y/277 VAC 3 PH 60 HZ", | |
| "RATING: 750 KVA / 675 KW", | |
| "INPUT CURRENT: 1002 A", | |
| "MFG DATE: 03/2026" | |
| ] | |
| }, | |
| { | |
| "id": "ups-wrong-voltage", | |
| "type": "ups", | |
| "expect_tag": "UPS-1A", | |
| "expect_mismatch": ["model", "voltage"], | |
| "lines": [ | |
| "NORTHLINE POWER SYSTEMS", | |
| "UNINTERRUPTIBLE POWER SUPPLY", | |
| "MODEL NO: NPX-750-415", | |
| "SERIAL NO: NL26A02210", | |
| "INPUT: 415Y/240 VAC 3 PH 50 HZ", | |
| "RATING: 750 KVA / 675 KW", | |
| "INPUT CURRENT: 1160 A", | |
| "MFG DATE: 04/2026" | |
| ] | |
| }, | |
| { | |
| "id": "switchboard", | |
| "type": "switchgear", | |
| "expect_tag": null, | |
| "lines": [ | |
| "IRONSIDE SWITCHGEAR CORP", | |
| "SWITCHBOARD", | |
| "MODEL NO: IS-4000-MDP", | |
| "SERIAL NO: IS26C01188", | |
| "480Y/277 V 3 PH 60 HZ", | |
| "1000 KVA MAIN BUS", | |
| "SCCR 65 KAIC NEMA 3R", | |
| "MFG DATE: 05/2026" | |
| ] | |
| }, | |
| { | |
| "id": "server-rack", | |
| "type": "server", | |
| "expect_tag": null, | |
| "lines": [ | |
| "DELL EMC", | |
| "POWEREDGE R650 SERVER", | |
| "MODEL NO: R650-2U", | |
| "SERIAL NO: DL26R00442", | |
| "480 V 3 PH 60 HZ", | |
| "800 W 12.5 A", | |
| "AIRFLOW 120 CFM", | |
| "MFG DATE: 06/2026" | |
| ] | |
| }, | |
| { | |
| "id": "rack-pdu", | |
| "type": "pdu", | |
| "expect_tag": null, | |
| "lines": [ | |
| "VERTIV", | |
| "RACK PDU", | |
| "MODEL NO: MPX-30-C13", | |
| "SERIAL NO: VR26P00117", | |
| "400 V 3 PH 60 HZ", | |
| "30 A 5.5 KW", | |
| "24 OUTLETS (12x C13, 4x C19)", | |
| "MFG DATE: 08/2026" | |
| ] | |
| }, | |
| { | |
| "id": "network-switch", | |
| "type": "network", | |
| "expect_tag": null, | |
| "lines": [ | |
| "CISCO", | |
| "CATALYST NETWORK SWITCH", | |
| "MODEL NO: C9300-48P", | |
| "SERIAL NO: FOC26X0011", | |
| "230 V 3 PH 50 HZ", | |
| "48-PORT POE 1100 W", | |
| "UPLINK 25G", | |
| "MFG DATE: 09/2026" | |
| ] | |
| }, | |
| { | |
| "id": "blade-chassis", | |
| "type": "server", | |
| "expect_tag": null, | |
| "lines": [ | |
| "NEXUS COMPUTE", | |
| "BLADE SERVER CHASSIS", | |
| "MODEL NO: BX-7000", | |
| "SERIAL NO: NC26B00123", | |
| "FORM FACTOR 8U", | |
| "480 V 3 PH 60 HZ", | |
| "STATIC LOAD 1360 KG", | |
| "MFG DATE: 05/2026" | |
| ] | |
| } | |
| ] | |
| } | |