Image-to-Text
English
custom
ocr
document-ai
information-extraction
key-information-extraction
nameplate
nameplate-ocr
equipment-nameplate
data-center
data-centre
datacenter
mission-critical
mep
electrical
mechanical
equipment-schedule
schedule-verification
asset-register
commissioning
quality-assurance
ups
pdu
switchgear
generator
ats
transformer
busway
battery
crah
crac
chiller
cooling
server-rack
construction
aec
edge-ai
on-device
privacy-preserving
tesseract
browser
Eval Results (legacy)
File size: 2,988 Bytes
5e2d1eb bc4e333 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff bc4e333 2843cff bc4e333 5e2d1eb | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 | {
"note": "Fictional sample plates. UPS-1A matches schedule tag UPS-1A; the 415 V UPS is the same family but a different voltage variant, so it is flagged on model and voltage. The switchboard and the IT gear are not on the sample schedule, showing wider equipment recognition and the server-rack fields (Rack U, Form factor, Power W, Rack load, Outlet mix, Port speed, Ports).",
"plates": [
{
"id": "ups-match",
"type": "ups",
"expect_tag": "UPS-1A",
"lines": [
"NORTHLINE POWER SYSTEMS",
"UNINTERRUPTIBLE POWER SUPPLY",
"MODEL NO: NPX-750-480",
"SERIAL NO: NL26A01937",
"INPUT: 480Y/277 VAC 3 PH 60 HZ",
"RATING: 750 KVA / 675 KW",
"INPUT CURRENT: 1002 A",
"MFG DATE: 03/2026"
]
},
{
"id": "ups-wrong-voltage",
"type": "ups",
"expect_tag": "UPS-1A",
"expect_mismatch": ["model", "voltage"],
"lines": [
"NORTHLINE POWER SYSTEMS",
"UNINTERRUPTIBLE POWER SUPPLY",
"MODEL NO: NPX-750-415",
"SERIAL NO: NL26A02210",
"INPUT: 415Y/240 VAC 3 PH 50 HZ",
"RATING: 750 KVA / 675 KW",
"INPUT CURRENT: 1160 A",
"MFG DATE: 04/2026"
]
},
{
"id": "switchboard",
"type": "switchgear",
"expect_tag": null,
"lines": [
"IRONSIDE SWITCHGEAR CORP",
"SWITCHBOARD",
"MODEL NO: IS-4000-MDP",
"SERIAL NO: IS26C01188",
"480Y/277 V 3 PH 60 HZ",
"1000 KVA MAIN BUS",
"SCCR 65 KAIC NEMA 3R",
"MFG DATE: 05/2026"
]
},
{
"id": "server-rack",
"type": "server",
"expect_tag": null,
"lines": [
"DELL EMC",
"POWEREDGE R650 SERVER",
"MODEL NO: R650-2U",
"SERIAL NO: DL26R00442",
"480 V 3 PH 60 HZ",
"800 W 12.5 A",
"AIRFLOW 120 CFM",
"MFG DATE: 06/2026"
]
},
{
"id": "rack-pdu",
"type": "pdu",
"expect_tag": null,
"lines": [
"VERTIV",
"RACK PDU",
"MODEL NO: MPX-30-C13",
"SERIAL NO: VR26P00117",
"400 V 3 PH 60 HZ",
"30 A 5.5 KW",
"24 OUTLETS (12x C13, 4x C19)",
"MFG DATE: 08/2026"
]
},
{
"id": "network-switch",
"type": "network",
"expect_tag": null,
"lines": [
"CISCO",
"CATALYST NETWORK SWITCH",
"MODEL NO: C9300-48P",
"SERIAL NO: FOC26X0011",
"230 V 3 PH 50 HZ",
"48-PORT POE 1100 W",
"UPLINK 25G",
"MFG DATE: 09/2026"
]
},
{
"id": "blade-chassis",
"type": "server",
"expect_tag": null,
"lines": [
"NEXUS COMPUTE",
"BLADE SERVER CHASSIS",
"MODEL NO: BX-7000",
"SERIAL NO: NC26B00123",
"FORM FACTOR 8U",
"480 V 3 PH 60 HZ",
"STATIC LOAD 1360 KG",
"MFG DATE: 05/2026"
]
}
]
}
|