Dataset Viewer
Auto-converted to Parquet Duplicate
basis
string
category
string
derived_fields
list
id
string
iec_designation
string
north_american_designation
string
source
string
source_quote
string
url
string
verified_fields
list
iec_standard
string
disagreements
list
also_reported
list
max_surface_temperature_c
string
Risk gradation
system attribute
[ "category" ]
3-levels-zone-0-1-2-system-attribute-2-levels-div-1-div-2
3 levels (Zone 0, 1, 2)
2 levels (Div 1, Div 2)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Risk gradation | 2 levels (Div 1, Div 2) | 3 levels (Zone 0, 1, 2) | 3 levels (Zone 0, 1, 2)
https://referencesource.org/ex-classification-system-crosswalk/3-levels-zone-0-1-2-system-attribute-2-levels-div-1-div-2/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Ignitable fibers
area classification
[ "category" ]
area-classification-class-iii
null
Class III
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Class III | Ignitable fibers
https://referencesource.org/ex-classification-system-crosswalk/area-classification-class-iii/
[ "basis", "north_american_designation" ]
null
null
null
null
Geographic use: USA, Canada vs EU, UK, most of the world
system attribute
[ "category" ]
atex-iecex-zone-system-attribute-nec-500-class-division
ATEX / IECEx (Zone)
NEC 500 (Class/Division)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Geographic use | USA, Canada | USA, Canada | EU, UK, most of the world
https://referencesource.org/ex-classification-system-crosswalk/atex-iecex-zone-system-attribute-nec-500-class-division/
[ "basis" ]
null
null
null
null
Grain, flour, plastic dusts
dust group
[ "category" ]
dust-group-class-ii-group-g
null
Class II, Group G
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
Class II, Group G
https://referencesource.org/ex-classification-system-crosswalk/dust-group-class-ii-group-g/
[ "north_american_designation" ]
null
null
null
null
Legal framework
system attribute
[ "category" ]
eu-directive-2014-34-eu-iecex-scheme-system-attribute-nfpa-70-adopted-by-ahjs
EU Directive 2014/34/EU / IECEx scheme
NFPA 70 (adopted by AHJs)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Legal framework | NFPA 70 (adopted by AHJs) | NFPA 70 (adopted by AHJs) | EU Directive 2014/34/EU / IECEx scheme
https://referencesource.org/ex-classification-system-crosswalk/eu-directive-2014-34-eu-iecex-scheme-system-attribute-nfpa-70-adopted-by-ahjs/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Contain the explosion inside the enclosure
protection concept
[ "category" ]
ex-d-flameproof-protection-concept-explosion-proof-xp
Ex d (Flameproof)
Explosion-proof (XP)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Explosion-proof (XP) | Ex d (Flameproof) | IEC 60079-1 | Contain the explosion inside the enclosure
https://referencesource.org/ex-classification-system-crosswalk/ex-d-flameproof-protection-concept-explosion-proof-xp/
[ "basis", "iec_designation", "iec_standard", "north_american_designation" ]
IEC 60079-1
null
null
null
Flameproof enclosure
protection concept
[ "category" ]
ex-d-protection-concept-flameproof-enclosure
Ex d
Flameproof enclosure
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Ex d | Flameproof enclosure
https://referencesource.org/ex-classification-system-crosswalk/ex-d-protection-concept-flameproof-enclosure/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Increased safety
protection concept
[ "category" ]
ex-e-protection-concept-increased-safety
Ex e
Increased safety
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Ex e | Increased safety
https://referencesource.org/ex-classification-system-crosswalk/ex-e-protection-concept-increased-safety/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Limit energy below ignition threshold
protection concept
[ "category" ]
ex-i-ex-ia-ex-ib-protection-concept-intrinsically-safe-is
Ex i (Ex ia, Ex ib)
Intrinsically Safe (IS)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Intrinsically Safe (IS) | Ex i (Ex ia, Ex ib) | IEC 60079-11 | Limit energy below ignition threshold
https://referencesource.org/ex-classification-system-crosswalk/ex-i-ex-ia-ex-ib-protection-concept-intrinsically-safe-is/
[ "basis", "iec_designation", "iec_standard", "north_american_designation" ]
IEC 60079-11
null
null
null
Intrinsic safety
protection concept
[ "category" ]
ex-i-protection-concept-intrinsically-safe
Ex i
Intrinsically Safe
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Ex i | Intrinsic safety
https://referencesource.org/ex-classification-system-crosswalk/ex-i-protection-concept-intrinsically-safe/
[ "basis", "iec_designation" ]
null
null
null
null
Encapsulation
protection concept
[ "category" ]
ex-m-protection-concept-encapsulation
Ex m
Encapsulation
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Ex m | Encapsulation
https://referencesource.org/ex-classification-system-crosswalk/ex-m-protection-concept-encapsulation/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Normal operation cannot cause ignition
protection concept
[ "category" ]
ex-na-ex-ec-protection-concept-non-incendive
Ex nA / Ex ec
Non-incendive
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Non-incendive | Ex nA / Ex ec | IEC 60079-15 / -7 | Normal operation cannot cause ignition
https://referencesource.org/ex-classification-system-crosswalk/ex-na-ex-ec-protection-concept-non-incendive/
[ "basis", "iec_designation", "iec_standard", "north_american_designation" ]
IEC 60079-15 / -7
null
null
null
Seal ignition source from atmosphere
protection concept
[ "category" ]
ex-nc-ex-m-protection-concept-hermetically-sealed
Ex nC / Ex m
Hermetically sealed
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Hermetically sealed | Ex nC / Ex m | IEC 60079-15 / -18 | Seal ignition source from atmosphere
https://referencesource.org/ex-classification-system-crosswalk/ex-nc-ex-m-protection-concept-hermetically-sealed/
[ "basis", "iec_designation", "iec_standard", "north_american_designation" ]
IEC 60079-15 / -18
null
null
null
Maintain positive pressure with inert gas
protection concept
[ "category" ]
ex-p-ex-px-ex-py-ex-pz-protection-concept-purged-pressurized
Ex p (Ex px, Ex py, Ex pz)
Purged/Pressurized
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Purged/Pressurized | Ex p (Ex px, Ex py, Ex pz) | IEC 60079-2 | Maintain positive pressure with inert gas
https://referencesource.org/ex-classification-system-crosswalk/ex-p-ex-px-ex-py-ex-pz-protection-concept-purged-pressurized/
[ "basis", "iec_designation", "iec_standard", "north_american_designation" ]
IEC 60079-2
null
null
null
Pressurization
protection concept
[ "category" ]
ex-p-protection-concept-pressurization
Ex p
Pressurization
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Ex p | Pressurization
https://referencesource.org/ex-classification-system-crosswalk/ex-p-protection-concept-pressurization/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Prevent dust ingress and limit surface temperature
protection concept
[ "category" ]
ex-t-dust-protection-by-enclosure-protection-concept-dust-ignition-proof
Ex t (Dust protection by enclosure)
Dust-ignition-proof
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Dust-ignition-proof | Ex t (Dust protection by enclosure) | IEC 60079-31 | Prevent dust ingress and limit surface temperature
https://referencesource.org/ex-classification-system-crosswalk/ex-t-dust-protection-by-enclosure-protection-concept-dust-ignition-proof/
[ "basis", "iec_designation", "iec_standard", "north_american_designation" ]
IEC 60079-31
null
null
null
Metal dust
gas group
[ "category" ]
gas-group-group-e
null
Group E
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
E | Metal dust
https://referencesource.org/ex-classification-system-crosswalk/gas-group-group-e/
[ "basis" ]
null
null
null
null
Carbon dust
gas group
[ "category" ]
gas-group-group-f
null
Group F
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
F | Carbon dust
https://referencesource.org/ex-classification-system-crosswalk/gas-group-group-f/
[ "basis" ]
null
null
null
null
Grain / flour dust
gas group
[ "category" ]
gas-group-group-g
null
Group G
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
G | Grain / flour dust
https://referencesource.org/ex-classification-system-crosswalk/gas-group-group-g/
[ "basis" ]
null
null
null
null
Gas classification
system attribute
[ "category" ]
groups-iic-iib-iia-system-attribute-groups-a-b-c-d
Groups IIC, IIB, IIA
Groups A, B, C, D
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Gas classification | Groups A, B, C, D | Groups IIC, IIB, IIA | Groups IIC, IIB, IIA
https://referencesource.org/ex-classification-system-crosswalk/groups-iic-iib-iia-system-attribute-groups-a-b-c-d/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Protection concept
system attribute
[ "category" ]
iec-aligned-types-ex-d-ex-i-ex-e-etc-system-attribute-explosion-proof-xp-intrinsically-safe-is
IEC-aligned types (Ex d, Ex i, Ex e, etc.)
Explosion-proof (XP), intrinsically safe (IS)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Protection concept | Explosion-proof (XP), intrinsically safe (IS) | IEC-aligned types (Ex d, Ex i, etc.) | IEC-aligned types (Ex d, Ex i, Ex e, etc.)
https://referencesource.org/ex-classification-system-crosswalk/iec-aligned-types-ex-d-ex-i-ex-e-etc-system-attribute-explosion-proof-xp-intrinsically-safe-is/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Propane
gas group
[ "category" ]
iia-gas-group-class-i-group-d
IIA
Class I, Group D
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
IIA | Propane | Class I, Group D |
https://referencesource.org/ex-classification-system-crosswalk/iia-gas-group-class-i-group-d/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
MESG >0.90 mm
gas group
[ "category" ]
iia-gas-group-group-d
IIA
Group D
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
D | IIA | Methane, propane, gasoline | >0.90 mm
https://referencesource.org/ex-classification-system-crosswalk/iia-gas-group-group-d/
[ "iec_designation" ]
null
[ { "field": "basis", "versions": [ { "as_of": "2026-08-06T00:00:00", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "D | IIA | Methane, propane, gasoline | >0.90 mm", "value": "MESG >0.90 mm" }, { "as_of": "2026-08...
null
null
Ethylene
gas group
[ "category" ]
iib-gas-group-class-i-group-c
IIB
Class I, Group C
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
IIB | Ethylene | Class I, Group C | Ethylene
https://referencesource.org/ex-classification-system-crosswalk/iib-gas-group-class-i-group-c/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
MESG 0.50–0.90 mm
gas group
[ "category" ]
iib-gas-group-group-c
IIB
Group C
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
C | IIB | Ethylene, ethyl ether | 0.50–0.90 mm
https://referencesource.org/ex-classification-system-crosswalk/iib-gas-group-group-c/
[ "iec_designation" ]
null
[ { "field": "basis", "versions": [ { "as_of": "2026-08-06T00:00:00", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "C | IIB | Ethylene, ethyl ether | 0.50–0.90 mm", "value": "MESG 0.50–0.90 mm" }, { "as_of": "2026...
null
null
Hydrogen
gas group
[ "category" ]
iib-h2-gas-group-class-i-group-b
IIB + H2
Class I, Group B
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
IIB + H 2 | Hydrogen | Class I, Group B | Hydrogen
https://referencesource.org/ex-classification-system-crosswalk/iib-h2-gas-group-class-i-group-b/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Acetylene
gas group
[ "category" ]
iic-gas-group-class-i-group-a
IIC
Class I, Group A
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
IIC | Acetylene | Class I, Group A | Acetylene
https://referencesource.org/ex-classification-system-crosswalk/iic-gas-group-class-i-group-a/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
MESG <0.50 mm
gas group
[ "category" ]
iic-gas-group-group-a
IIC
Group A
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
A | IIC | Acetylene | <0.50 mm
https://referencesource.org/ex-classification-system-crosswalk/iic-gas-group-group-a/
[ "iec_designation" ]
null
[ { "field": "basis", "versions": [ { "as_of": "2026-08-06T00:00:00", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "A | IIC | Acetylene | <0.50 mm", "value": "MESG <0.50 mm" }, { "as_of": "2026-08-06T00:00:00", ...
null
null
Hydrogen
gas group
[ "category" ]
iic-gas-group-group-b
IIC
Group B
https://ldpi-inc.com/resources/classification-codes/class-1-locations/
Hydrogen | B | 520 | 968 | 6,000 PSI | IIC
https://referencesource.org/ex-classification-system-crosswalk/iic-gas-group-group-b/
[ "basis", "iec_designation" ]
null
null
null
null
MESG <0.50 mm
gas group
[ "category" ]
iic-partially-iib-h-gas-group-group-b
IIC (partially IIB+H₂)
Group B
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
B | IIC (partially IIB+H₂) | Hydrogen, butadiene | <0.50 mm
https://referencesource.org/ex-classification-system-crosswalk/iic-partially-iib-h-gas-group-group-b/
[ "iec_designation" ]
null
null
null
null
Fibers and flyings
dust group
[ "category" ]
iiia-dust-group-class-iii
IIIA
Class III
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
Gas / dust group | Typical Substances | IIC | Acetylene | Class I, Group A | Acetylene | IIB + H 2 | Hydrogen | Class I, Group B | Hydrogen | IIB | Ethylene | Class I, Group C | Ethylene | IIA | Propane | Class I, Group D | Propane | IIIC | Conductive dust | Class II, Group E | Combustible metal dust | IIIB | Non-condu...
https://referencesource.org/ex-classification-system-crosswalk/iiia-dust-group-class-iii/
[ "iec_designation", "north_american_designation" ]
null
null
null
null
Carbon dusts
dust group
[ "category" ]
iiib-dust-group-class-ii-group-f
IIIB
Class II, Group F
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
Gas / dust group | Typical Substances | IIC | Acetylene | Class I, Group A | Acetylene | IIB + H 2 | Hydrogen | Class I, Group B | Hydrogen | IIB | Ethylene | Class I, Group C | Ethylene | IIA | Propane | Class I, Group D | Propane | IIIC | Conductive dust | Class II, Group E | Combustible metal dust | IIIB | Non-condu...
https://referencesource.org/ex-classification-system-crosswalk/iiib-dust-group-class-ii-group-f/
[ "iec_designation", "north_american_designation" ]
null
null
null
null
Metal dusts
dust group
[ "category" ]
iiic-dust-group-class-ii-group-e
IIIC
Class II, Group E
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
Gas / dust group | Typical Substances | IIC | Acetylene | Class I, Group A | Acetylene | IIB + H 2 | Hydrogen | Class I, Group B | Hydrogen | IIB | Ethylene | Class I, Group C | Ethylene | IIA | Propane | Class I, Group D | Propane | IIIC | Conductive dust | Class II, Group E |
https://referencesource.org/ex-classification-system-crosswalk/iiic-dust-group-class-ii-group-e/
[ "iec_designation", "north_american_designation" ]
null
null
null
null
Certification body
system attribute
[ "category" ]
notified-bodies-atex-excbs-iecex-system-attribute-nrtls-ul-fm-csa
Notified Bodies (ATEX) / ExCBs (IECEx)
NRTLs (UL, FM, CSA)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Certification body | NRTLs (UL, FM, CSA) | NRTLs | Notified Bodies (ATEX) / ExCBs (IECEx)
https://referencesource.org/ex-classification-system-crosswalk/notified-bodies-atex-excbs-iecex-system-attribute-nrtls-ul-fm-csa/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Ignition temperature of gas / dust >450
temperature code
[ "category" ]
t1-temperature-code-t1
T1
T1
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
450 | T1 | >450
https://referencesource.org/ex-classification-system-crosswalk/t1-temperature-code-t1/
[ "iec_designation", "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T1 | T1 | 450 | 842", "value": "842" } ]
450
Ignition temperature of gas / dust >300-450
temperature code
[ "category" ]
t2-temperature-code-t2
T2
T2
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
300 | T2 | >300-450
https://referencesource.org/ex-classification-system-crosswalk/t2-temperature-code-t2/
[ "iec_designation", "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2 | T2 | 300 | 572", "value": "572" } ]
300
Ignition temperature of gas / dust >200-300
temperature code
[ "category" ]
t3-temperature-code-t3
T3
T3
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
200 | T3 | >200-300
https://referencesource.org/ex-classification-system-crosswalk/t3-temperature-code-t3/
[ "iec_designation", "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T3 | T3 | 200 | 392", "value": "392" } ]
200
Ignition temperature of gas / dust >135-200
temperature code
[ "category" ]
t4-temperature-code-t4
T4
T4
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
135 | T4 | >135-200
https://referencesource.org/ex-classification-system-crosswalk/t4-temperature-code-t4/
[ "iec_designation", "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T4 | T4 | 135 | 275", "value": "275" } ]
135
Ignition temperature of gas / dust >100-135
temperature code
[ "category" ]
t5-temperature-code-t5
T5
T5
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
100 | T5 | >100-135
https://referencesource.org/ex-classification-system-crosswalk/t5-temperature-code-t5/
[ "iec_designation", "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T5 | T5 | 100 | 212", "value": "212" } ]
100
Ignition temperature of gas / dust >85-100
temperature code
[ "category" ]
t6-temperature-code-t6
T6
T6
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
85 | T6 | >85-100
https://referencesource.org/ex-classification-system-crosswalk/t6-temperature-code-t6/
[ "iec_designation", "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T6 | T6 | 85 | 185", "value": "185" } ]
85
Ignition temperature of gas / dust >280-300
temperature code
[ "category" ]
temperature-code-t2a
null
T2A
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
280 | T2A | >280-300
https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t2a/
[ "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2A | | 280 | 536", "value": "536" } ]
280
Ignition temperature of gas / dust >260-280
temperature code
[ "category" ]
temperature-code-t2b
null
T2B
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
260 | T2B | >260-280
https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t2b/
[ "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2B | | 260 | 500", "value": "500" } ]
260
Ignition temperature of gas / dust >230-260
temperature code
[ "category" ]
temperature-code-t2c
null
T2C
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
230 | T2C | >230-260
https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t2c/
[ "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2C | | 230 | 446", "value": "446" } ]
230
Ignition temperature of gas / dust >215-230
temperature code
[ "category" ]
temperature-code-t2d
null
T2D
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
215 | T2D | >215-230
https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t2d/
[ "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2D | | 215 | 419", "value": "419" } ]
215
Ignition temperature of gas / dust >180-200
temperature code
[ "category" ]
temperature-code-t3a
null
T3A
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
180 | T3A | >180-200
https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t3a/
[ "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T3A | | 180 | 356", "value": "356" } ]
180
Ignition temperature of gas / dust >165-180
temperature code
[ "category" ]
temperature-code-t3b
null
T3B
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
165 | T3B | >165-180
https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t3b/
[ "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T3B | | 165 | 329", "value": "329" } ]
165
Ignition temperature of gas / dust >160-165
temperature code
[ "category" ]
temperature-code-t3c
null
T3C
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
160 | T3C | >160-165
https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t3c/
[ "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T3C | | 160 | 320", "value": "320" } ]
160
Ignition temperature of gas / dust >120-135
temperature code
[ "category" ]
temperature-code-t4a
null
T4A
https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
120 | T4A | >120-135
https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t4a/
[ "max_surface_temperature_c", "north_american_designation" ]
null
[]
[ { "as_of": "2026-08-06T00:00:00", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T4A | | 120 | 248", "value": "248" } ]
120
Flammable gases and vapors
area classification
[ "category" ]
zone-0-1-2-gas-area-classification-class-i
Zone 0, 1, 2 (gas)
Class I
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Class I | Flammable gases and vapors
https://referencesource.org/ex-classification-system-crosswalk/zone-0-1-2-gas-area-classification-class-i/
[ "basis", "north_american_designation" ]
null
null
null
null
Hazard basis
system attribute
[ "category" ]
zone-0-1-2-gas-zone-20-21-22-dust-system-attribute-class-i-gas-ii-dust-iii-fibers
Zone 0, 1, 2 (gas); Zone 20, 21, 22 (dust)
Class I (gas), II (dust), III (fibers)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Hazard basis | Class I (gas), II (dust), III (fibers) | Zone 0, 1, 2 (gas only) | Zone 0, 1, 2 (gas); Zone 20, 21, 22 (dust)
https://referencesource.org/ex-classification-system-crosswalk/zone-0-1-2-gas-zone-20-21-22-dust-system-attribute-class-i-gas-ii-dust-iii-fibers/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Continuous hazard
area classification
[ "category" ]
zone-0-area-classification-class-i-division-1
Zone 0
Class I Division 1
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Continuous hazard | Class I Division 1 | Zone 0
https://referencesource.org/ex-classification-system-crosswalk/zone-0-area-classification-class-i-division-1/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Explosive atmosphere continuously or for long periods (>1000 hrs/yr)
area classification
[ "category" ]
zone-0-area-classification-no-nec-500-equivalent
Zone 0
(no NEC 500 equivalent)
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Zone 0 | Explosive atmosphere continuously or for long periods (>1000 hrs/yr)
https://referencesource.org/ex-classification-system-crosswalk/zone-0-area-classification-no-nec-500-equivalent/
[ "basis", "iec_designation" ]
null
null
null
null
Explosive atmosphere present continuously or for long periods
area classification
[ "category" ]
zone-0-area-classification-no-nec-equivalent
Zone 0
(no NEC equivalent)
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Zone 0 | Explosive atmosphere present continuously or for long periods
https://referencesource.org/ex-classification-system-crosswalk/zone-0-area-classification-no-nec-equivalent/
[ "basis", "iec_designation" ]
null
null
null
null
Hazard present during normal operation
area classification
[ "category" ]
zone-0-zone-1-area-classification-division-1
Zone 0 / Zone 1
Division 1
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Division 1 | Hazard present during normal operation
https://referencesource.org/ex-classification-system-crosswalk/zone-0-zone-1-area-classification-division-1/
[ "basis", "north_american_designation" ]
null
null
null
null
Frequent hazard
area classification
[ "category" ]
zone-1-area-classification-class-i-division-1
Zone 1
Class I Division 1
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Frequent hazard | Class I Division 1 | Zone 1
https://referencesource.org/ex-classification-system-crosswalk/zone-1-area-classification-class-i-division-1/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Explosive atmosphere likely during normal operation
area classification
[ "category" ]
zone-1-area-classification-no-nec-equivalent
Zone 1
(no NEC equivalent)
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Zone 1 | Explosive atmosphere likely during normal operation
https://referencesource.org/ex-classification-system-crosswalk/zone-1-area-classification-no-nec-equivalent/
[ "basis", "iec_designation" ]
null
null
null
null
Explosive atmosphere likely during normal operation (10–1000 hrs/yr)
area classification
[ "category" ]
zone-1-zone-0-area-classification-division-1
Zone 1 (+ Zone 0)
Division 1
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Division 1 | Zone 1 (+ Zone 0) | Explosive atmosphere likely during normal operation (10–1000 hrs/yr)
https://referencesource.org/ex-classification-system-crosswalk/zone-1-zone-0-area-classification-division-1/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Occasional hazard
area classification
[ "category" ]
zone-2-area-classification-class-i-division-2
Zone 2
Class I Division 2
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Occasional hazard | Class I Division 2 | Zone 2
https://referencesource.org/ex-classification-system-crosswalk/zone-2-area-classification-class-i-division-2/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)
area classification
[ "category" ]
zone-2-area-classification-division-2
Zone 2
Division 2
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Division 2 | Zone 2 | Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)
https://referencesource.org/ex-classification-system-crosswalk/zone-2-area-classification-division-2/
[ "basis", "iec_designation", "north_american_designation" ]
null
[ { "field": "basis", "versions": [ { "as_of": "2026-08-06T00:00:00", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Division 2 | Zone 2 | Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)", "value": "Explosive at...
null
null
Explosive atmosphere unlikely in normal operation, only short duration eg. accidental leakage
area classification
[ "category" ]
zone-2-area-classification-no-nec-equivalent
Zone 2
(no NEC equivalent)
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Zone 2 | Explosive atmosphere unlikely in normal operation, only short duration eg. accidental leakage
https://referencesource.org/ex-classification-system-crosswalk/zone-2-area-classification-no-nec-equivalent/
[ "basis", "iec_designation" ]
null
null
null
null
Combustible dust
area classification
[ "category" ]
zone-20-21-22-dust-area-classification-class-ii
Zone 20, 21, 22 (dust)
Class II
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Class II | Combustible dust
https://referencesource.org/ex-classification-system-crosswalk/zone-20-21-22-dust-area-classification-class-ii/
[ "basis", "north_american_designation" ]
null
null
null
null
Dust classification
system attribute
[ "category" ]
zone-20-21-22-iiia-iiib-iiic-system-attribute-class-ii-groups-e-f-g
Zone 20, 21, 22 (IIIA, IIIB, IIIC)
Class II Groups E, F, G
https://exknowledge.com/pages/nec-500-vs-atex-iec.html
Dust classification | Class II Groups E, F, G | Not covered | Zone 20, 21, 22 (IIIA, IIIB, IIIC)
https://referencesource.org/ex-classification-system-crosswalk/zone-20-21-22-iiia-iiib-iiic-system-attribute-class-ii-groups-e-f-g/
[ "basis", "iec_designation", "north_american_designation" ]
null
null
null
null
Combustible dust present continuously
area classification
[ "category" ]
zone-20-area-classification-no-nec-equivalent
Zone 20
(no NEC equivalent)
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Zone 20 | Combustible dust present continuously
https://referencesource.org/ex-classification-system-crosswalk/zone-20-area-classification-no-nec-equivalent/
[ "basis", "iec_designation" ]
null
null
null
null
Dust likely during normal operation
area classification
[ "category" ]
zone-21-area-classification-no-nec-equivalent
Zone 21
(no NEC equivalent)
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Zone 21 | Dust likely during normal operation
https://referencesource.org/ex-classification-system-crosswalk/zone-21-area-classification-no-nec-equivalent/
[ "basis", "iec_designation" ]
null
null
null
null
Dust unlikely except briefly
area classification
[ "category" ]
zone-22-area-classification-no-nec-equivalent
Zone 22
(no NEC equivalent)
https://www.inframena.com/hazardous-area-classification-equivalency-guide/
Zone 22 | Dust unlikely except briefly
https://referencesource.org/ex-classification-system-crosswalk/zone-22-area-classification-no-nec-equivalent/
[ "basis", "iec_designation" ]
null
null
null
null

North American vs IEC/ATEX explosion protection designations

Canonical, always-current version: https://referencesource.org/ex-classification-system-crosswalk/ Machine-readable: https://referencesource.org/ex-classification-system-crosswalk/data.json — this mirror is a point-in-time copy.

  • Last verified: 2026-08-06
  • Stale after: 2028-08-05 (past this date, prefer the canonical copy — it re-verifies on a cadence this snapshot does not)
  • Records: 65

Crosswalk between the two concurrent hazardous-area classification systems: the North American Class / Division system of NEC Articles 500 and 505 (NFPA 70) and the CSA code, against the Zone system of IEC 60079, ATEX and IECEx. Each record is one designation in one system with its stated counterpart in the other, covering area classification (Division 1 and 2 against Zone 0, 1, 2, 20, 21, 22), gas groups (A, B, C, D against IIA, IIB, IIC, IIB+H2), dust groups (E, F, G against IIIA, IIIB, IIIC), protection concepts (explosion-proof against Ex d, intrinsically safe against Ex i, purged/pressurized against Ex p, dust-ignition-proof against Ex t, non-incendive against Ex nA/Ex ec) with the IEC standard number for each, and temperature codes T1 to T6 with their maximum surface temperatures. Answers 'is ATEX Ex d IIB T4 the same as Class I Div 1 Group C', 'what does T2D mean and is there an IEC equivalent', 'Division 1 or Zone 1 which is stricter', 'NEC Group B IEC equivalent', and 'can I install Zone 1 equipment in a Division 1 area'. Three things the mapping gets wrong when stated as a simple table: NEC 500 has no Zone 0 equivalent so Division 1 spans Zone 0 and Zone 1 and is under-specified for Zone 0; the North American temperature codes T2A, T2B, T2C, T2D, T3A, T3B, T3C and T4A have no IEC counterpart at all; and publishers disagree on NEC Group B, giving it as IIC or as IIB+H2, which changes the required flameproof gap. Every counterpart is quoted from the page that stated it and attributed, so the disagreement is visible.

Provenance — what every record carries

Every record carries source (the URL the value was read from) and source_quote (a verbatim quote from that page stating it). A value you cannot check against its page is indistinguishable from an invented one; these can all be checked. Each record is also individually addressable on the canonical site at its url.

Licence position

Facts extracted from freely published manufacturer and industry reference pages. Designation crosswalks are safety facts, not copyrightable expression. NFPA 70 and the IEC 60079 series are not reproduced and were not opened -- the fact is taken, never the document. Four separate publishers, no bulk take from any one.

Facts are not copyrightable; what this dataset takes from each source is a fact plus a short attributed quote linking back to the page that states it.

Sources

Fields

See any record in data/records.jsonl — field names are self-describing, and the canonical page for each record renders them with labels: https://referencesource.org/ex-classification-system-crosswalk/

Downloads last month
34