# Check if last bolus time is recent |
if int(time.time()) - lastBolusTime < 2*UPDATE_INTERVAL: |
print("Bolus time is recent") |
blynk.virtual_write(VPIN_LASTBOLUS, data["lastBolusAmount"]) |
else: |
blynk.virtual_write(VPIN_ACTINS, data["activeInsulin"]) |
else: |
syslog.syslog(syslog.LOG_ERR, "Unable to get data from pump") |
blynk.set_property(VPIN_STATUS, "color", BLYNK_RED) |
######################################################### |
# |
# Function: upload_live_data() |
# Description: Read live data from pump and upload it |
# to the enabled cloud services |
# This runs once at startup and then as a |
# periodic timer every 5min |
# |
######################################################### |
def upload_live_data(): |
global cycleCount |
global cycleTimer |
# Guard against multiple threads |
if upload_live_data.active: |
return |
upload_live_data.active = True |
print("read live data from pump") |
hasFailed = True |
numRetries = MAX_RETRIES_AT_FAILURE |
while hasFailed and numRetries > 0: |
try: |
liveData = cnl24driverlib.readLiveData() |
hasFailed = False |
except: |
print("unexpected ERROR occured while reading live data") |
syslog.syslog(syslog.LOG_ERR, "Unexpected ERROR occured while reading live data") |
liveData = None |
numRetries -= 1 |
if numRetries > 0: |
time.sleep(RETRY_DELAY) |
# Account for pump RTC drift |
if liveData != None: |
print("account for pump RTC drift:") |
print(" before: pumpTime {0}, sensorBGLTimestamp {1}".format(liveData["pumpTime"], liveData["sensorBGLTimestamp"])) |
liveData["pumpTime"] += liveData["pumpTimeDrift"] |
if liveData["sensorBGL"] != SENSOR_EXCEPTIONS.SENSOR_LOST: |
liveData["sensorBGLTimestamp"] += liveData["pumpTimeDrift"] |
print(" after : pumpTime {0}, sensorBGLTimestamp {1}".format(liveData["pumpTime"], liveData["sensorBGLTimestamp"])) |
# Upload data to Blynk server |
if blynk != None: |
try: |
blynk_upload(liveData) |
except: |
syslog.syslog(syslog.LOG_ERR, "Blynk upload ERROR") |
# Upload data to Nighscout server |
if nightscout != None: |
try: |
nightscout.upload(liveData) |
except: |
syslog.syslog(syslog.LOG_ERR, "Nightscout upload ERROR") |
# Calculate time until next reading |
if liveData != None: |
nextReading = liveData["sensorBGLTimestamp"] + datetime.timedelta(seconds=UPDATE_INTERVAL) |
tmoSeconds = int((nextReading - datetime.datetime.now(liveData["pumpTime"].tzinfo)).total_seconds()) |
print("Next reading at {0}, {1} seconds from now\n".format(nextReading,tmoSeconds)) |
if tmoSeconds < 0: |
tmoSeconds = RETRY_INTERVAL |
else: |
tmoSeconds = RETRY_INTERVAL |
print("Retry reading {0} seconds from now\n".format(tmoSeconds)) |
# Start timer for next cycle |
cycleTimer = threading.Timer(tmoSeconds+10, upload_live_data) |
cycleTimer.start() |
cycleCount += 1 |
upload_live_data.active = False |
########################################################## |
# Setup |
########################################################## |
# read configuration parameters |
if read_config(CONFIG_FILE) == False: |
sys.exit() |
blynk_enabled = (read_config.blynk_token != "") and (read_config.blynk_server != "") |
nightscout_enabled = (read_config.nightscout_server != "") and (read_config.nightscout_api_secret != "") |