539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.6.2 Routing Policy
The Routing Policy field, specified in 3GPP TS 29.234 [63], defines a packet filter for an IP flow.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.6.3 Subscribed 3GPP WLAN QoS Profile
The Subscribed 3GPP WLAN QoS Profile field, specified in 3GPP TS 29.234 [63], defines a subscribed 3GPP WLAN QoS profile per W-APN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.6.4 Authorized 3GPP WLAN QoS Profile
The Authorized 3GPP WLAN QoS Profile field, specified in 3GPP TS 29.234 [63], defines the authorized 3GPP WLAN QoS profile per W-APN for a user.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7 Data related to Charging
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7.1 Charging Data
The Charging Data field identifies the Charging Characteristics plus the Charging Nodes to be applied per user for all W‑APNs or per user for individual W‑APNs.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7.1.1 Charging Characteristics
Charging Characteristics field is defined in 3GPP TS 32.252 [66]. It indicates the charging type to be applied to the user tunnel.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7.2 Primary OCS Charging Function Name
The Primary OCS Charging Function Name field identifies the Primary OCS Function node that performs on-line based charging. The format is specified in 3GPP TS 29.234 [63].
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7.3 Secondary OCS Charging Function Name
The Secondary OCS Charging Function Name field identifies the Secondary OCS Charging Function node that performs on-line based charging. The format is specified in 3GPP TS 29.234 [63].
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7.4 Primary Charging Collection Function Name
The Primary Charging Collection Function Name field identifies the primary Charging Collection Function node that provides off-line charging support for the IMS subscribers. The format is specified in 3GPP TS 29.234 [63].
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7.5 Secondary Charging Collection Function Name
The Secondary Charging Collection Function Name field identifies the secondary Charging Collection Function node that provides off-line charging support for the IMS subscribers. The format is specified in 3GPP TS 29.234 [63].
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7.6 WLAN Session Identifier
The WLAN Session Identifier is the identifier generated by 3GPP AAA Server and sent to PDG. Togther with PDG Charging Identifier, it is used for correlating WLAN AN and PDG charging data. The format is specified in 3GPP TS 32.299 [67].
539f847bb6cd6c0ba766caacc29710d4
23.008
3.11.7.7 PDG Charging Identifier
The PDG Charging Identifier is the identifier generated by PDG and sent to 3GPP AAA Server. Togther with WLAN Session Identifier, it is used for correlating WLAN AN and PDG charging data. The format is specified in 3GPP TS 32.299 [67].
539f847bb6cd6c0ba766caacc29710d4
23.008
3.12 Data related to Access Network Discovery and Selection Function (ANDSF)
539f847bb6cd6c0ba766caacc29710d4
23.008
3.12.1 General
Following clauses describe the Data that is defined on per user basis and is related to Access Network Discovery and Selection Function (ANDSF).
539f847bb6cd6c0ba766caacc29710d4
23.008
3.12.2 Policy Information
This set and contains a list of inter-system mobility policies. Each policy contains the following information while the corresponding coding is defined in 3GPP TS 24.312 [86]: - Rule Priority: indicates the priority of the correspondent intersystem mobility policy; - Prioritized Access: a set of information providing ...
539f847bb6cd6c0ba766caacc29710d4
23.008
3.12.3 Discovery Information
This set contains the information regarding the access networks the UE can discover. It contains the following information while the corresponding coding is defined in 3GPP TS 24.312 [86]: - Access Network Type: indicates the type of the network for which discovery assistance information is provided; - Access Network A...
539f847bb6cd6c0ba766caacc29710d4
23.008
3.12.4 UE Location
This set provides information about the UE location, i.e. it is a way to indicate the position of the UE. This information can be used by ANDSF to limit the number of information sent to the UE. Different ways to describe the UE location are provided in 3GPP TS 24.312 [86]. This set is temporary data conditionally stor...
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13 Proximity Services (ProSe)
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.1 General
Following clauses describe the data that are defined on per user basis and are related to Proximity Services (ProSe).
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.2 ProSe Subscription data
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.2.1 ProSe-Permission
The ProSe-permision is part of the ProSe Subscription data information and is specified in 3GPP TS 29.344 [99]. ProSe-permission is permanent data conditionaly stored in HSS, MME and ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.2.2 PLMN-Allowed-ProSe
The PLMN-Allowed-ProSe is part of the ProSe Subscription data and is specified in 3GPP TS 29.344 [99]. PLMN-Allowed-ProSe is permanent data conditionally stored in HSS, MME and ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.3 Application layer user ID
The Application layer user ID is specified in 3GPP TS 23.303 [98]. Application layer user ID is permanent data conditionally stored in ProSe Function and ProSe Application Server.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.4 EPC ProSe User ID
The EPC ProSe User user ID is specified in 3GPP TS 23.003 [5]. EPC ProSe User ID is temporary data conditionally stored in ProSe Function, ProSe Application Server
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.5 ProSe Application ID
The ProSe Application ID is specified in 3GPP TS 23.003 [5]. ProSe Application ID is permanent data conditionally stored in ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.6 ProSe Application Code
The ProSe Application Code is specified in 3GPP TS 23.003 [5]. ProSe Application Code is temporary data conditionally stored in ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.7 Discovery Filter
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.7.1 Filter ID
The Filter ID part of the Discovery Filter is specified in 3GPP TS 24.334 [100]. Filter ID is permanent data conditionally stored in ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.7.2 ProSe Application Code
The ProSe Application Code as part of the Discovery Filter is specified in 3GPP TS 23.003 [5]. ProSe Application Code is permanent data conditionally stored in ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.7.3 ProSe Application Mask
The ProSe Application Mask as part of the Discovery Filter is specified in 3GPP TS 24.334 [100]. ProSe Application Mask as part of the discovery filter is permanent data conditionally stored in ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.7.4 TTLTimer T4002
The TTLTimer T4002 as part of the Discovery Filter is specified in 3GPP TS 24.334 [100]. The TTLTimer T4002 as part of the discovery filter is permanent data conditionally stored in ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.8 ProSe Function Identity
ProSe Function Identity is specified in 3GPP TS 29.344 [99]. The ProSe Function Identity is temporary subscriber data and is conditionaly stored in the HSS and in the ProSe Application Server.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.9 ProSe Metadata Index Mask
The ProSe Metadata Index Mask indicates which part of the ProSe Application Code contains the metadata index. It is specified in 3GPP TS 24.334 [100]. ProSe Metadata Index Mask is permanent data conditionally stored in ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.13.10 PC5-tech
The PC5-tech indicates the PC5 radio technology in order to enable co-ordination between the announcing and monitoring side. It is specified in 3GPP TS 24.334 [100]. PC5-tech is temporary data conditionally stored in ProSe Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14 Architecture Enhancements for Service Exposure (AESE)
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.1 General
Following clauses describe the data that are defined on a per user basis and are related to Architecture Enhancements for Service Exposure (AESE).
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.2 SCEF-Reference-ID
SCEF-Reference-ID is defined in 3GPP TS 29.336 [103]. SCEF-Reference-ID is used to uniquely identify an event created by an SCEF. SCEF-Reference-ID is temporary data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.3 SCEF-ID
SCEF-ID is defined in 3GPP TS 29.336 [103]. SCEF-ID is used to uniquely identify an SCEF. SCEF-ID is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.4 Monitoring-Type
Monitoring-Type is defined in 3GPP TS 29.336 [103]. Monitoring-Type is used to identify type the event to be monitored. Monitoring-Type is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.5 Maximum-Number-of-Reports
Maximum-Number-of-Reports is defined in 3GPP TS 29.336 [103]. Maximum-Number-of-Reports is used to indicate the number of reports to be delivered to the SCEF. Maximum-Number-of-Reports is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.6 UE-Reachability-Configuration
UE-Reachability-Configuration number is defined in 3GPP TS 29.336 [103]. UE-Reachability-Configuration contain details for configuration for UE reachability. UE-Reachability-Configuration is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.7 Monitoring-Duration
Monitoring-Duration is defined in 3GPP TS 29.336 [103]. Monitoring-Duration indicates the time for which the SCEF request to perform the monitoring. Monitoring-Duration is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.8 Maximum-Detection-Time
Maximum-Detection-Time is defined in 3GPP TS 29.336 [103]. Maximum-Detection-Time contains the maximum number of time without any communication with the UE after which the SCEF is to be informed that the UE is considered to be unreachable. Maximum-Detection-Time is permanent data conditionaly stored in the SCEF and HSS...
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.9 Reachability-Type
Reachability-Type is defined in 3GPP TS 29.336 [103]. Reachability-Type indicates for which kind of reachability of the subscriber needs to be reported i.e. reachable for SMS or data. Reachability-Type is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.10 Maximum-Latency
Maximum Latency is defined in 3GPP TS 29.336 [103]. Maximum Latency contains the maximum acceptable delay time for downlink data transfer. Maximum Latency is permanent data conditionaly stored in the SCEFand HSS.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.11 Maximum-Response-Time
Maximum Response Time is defined in 3GPP TS 29.336 [103]. Maximum Response Time contains the maximum time for which the UE stays reachable. Maximum Response Time is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.12 MONTE-Location-Type
MONTE-Location-Type is defined in 3GPP TS 29.336 [103]. MONTE-Location-Type indicates how actual the location information should be. Location-Type is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.13 Accuracy
Accuracy is defined in 3GPP TS 29.336 [103]. Accuracy is used to indicate in which form geographic location information has to be provided in the report. Accuracy is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.14 Association-Type
Association-Type is defined in 3GPP TS 29.336 [103]. Association-Type indicates which kind (IMEI or SV) of change of the IMEI has to be reported. Association-Type is permanent data conditionaly stored in the SCEF and HSS.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.15 Charged-Party
Charged-Party is defined in 3GPP TS 32.299 [67]. Charged-Party holds the address (Public User ID: SIP URI, Tel URI, etc.) of the party to be charged. Charged-Party is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.16 Remaining-number-of-reports
Remaining number of reports is defined in 3GPP TS 29.336 [103]. Remaining number of reports holds the number of reports which are outstanding to be sent to the SCEF. Remaining number of reports is temporary data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.17 Communication Pattern set
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.17.1 Periodic-Communication-Indicator
Periodic-Communication-Indicator is defined in 3GPP TS 29.336 [103]. Periodic-Communication-Indicator provides information if the CP occurs periodically or on demand. Periodic-Communication-Indicator is permanent data conditionaly stored in the SCEF, HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.17.2 Communication-Duration-Time
Communication-duration-time is defined in 3GPP TS 29.336 [103]. Communication-duration-time contains the time in seconds of the duration of the periodic communication. Communication-duration-time is permanent data conditionaly stored in the SCEF, HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.17.3 Periodic-Time
Periodic-Time is defined in 3GPP TS 29.336 [103]. Periodic-Time contains the time in seconds of the interval for periodic communication. Periodic-Time is permanent data conditionaly stored in the SCEF, HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.17.4 Scheduled-Communication-Time
Scheduled-Communication-Time is defined in 3GPP TS 29.336 [103]. Scheduled-Communication-Time contains start and end times and repetion during a week for periodic communication. Scheduled-Communication-Time is permanent data conditionaly stored in the SCEF, HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.17.5 Stationary-Indication
Stationary-Indication is defined in 3GPP TS 29.336 [103]. Stationary-Indication contains the information if the subscriber is stationary or mobile. Stationary-Indication is permanent data conditionaly stored in the SCEF, HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.17.6 Validity-Time
Validity-Time is defined in 3GPP TS 29.336 [103]. Validity-Time provides the expiration time at which the CP sets shall be deleteted. Validity-Time is permanent data conditionaly stored in the SCEF, HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.18 AESE-Subscription-Data
AESE-Subscription-Data contains details on subscription information of the allowed services such as: -allowed service (e.g. monitoring, CP set); -allowed service types (e.g. allowed Monitoring events). AESE-Subscription-Data is permanent data conditionally stored in the HSS.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.19 SCEF-Realm
SCEF-Realm is defined in 3GPP TS 29.272 [81]. SCEF-Realm is used to identify the realm of the SCEF. SCEF-Realm is permanent data conditionaly stored in the SCEF, HSS, MME and SGSN.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.20 External Identifier for Monitoring Event Configuration
The External Identifier for Monitoring Event Configuration contains an External Identifier as defined in 3GPP TS 23.003 [5] and identifies the External Identifier in the subscription that is associated to each Monitoring Event Configuration (MONTE) data instance. The External Identifier for each Monitoring Event Config...
539f847bb6cd6c0ba766caacc29710d4
23.008
3.14.21 External Group Identifier
The External Group Identifier contains an External Group Identifier as defined in 3GPP TS 23.003 [5]. The External Group Identifier for Monitoring Event Configuration is permanent subscriber data and is stored in the HSS and conditionally in the SCEF.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.15 Data related to WebRTC
539f847bb6cd6c0ba766caacc29710d4
23.008
3.15.1 Allowed WAF and/or WWSF Identity List
An Allowed WAF or WWSF Identity identifies a WebRTC Authentication Function or WebRTC Web Server Function the subscription is allowed to use. See 3GPP TS 33.203 [49]. Multiple WAF or WWSF identities may be stored within the Allowed WAF and/or WWSF Identity List. The Allowed WAF and/or WWSF Identity List is permanent da...
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16 V2X Service (V2X)
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.1 General
Following clauses describe the data that are defined on per user basis and are related to V2X Service (V2X).
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.2 V2X Subscription data for the network scheduled LTE sidelink communication
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.2.1 V2X-Permission
The V2X-Permision is part of the V2X Subscription data information for the network scheduled LTE sidelink communication and is specified in 3GPP TS 29.272 [81]. V2X-Permission is permanent data conditionally stored in HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.2.2 UE-PC5-AMBR
The UE-PC5-AMBR is part of the V2X Subscription data information for the network scheduled LTE sidelink communication and is specified in 3GPP TS 29.272 [81]. UE-PC5-AMBR is permanent data conditionally stored in HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.2.3 V2X-PC5-Allowed-PLMN
The V2X-PC5-Allowed-PLMN is part of the V2X Subscription data and is specified in 3GPP TS 29.388 [108]. V2X-PC5-Allowed-PLMN is permanent data conditionally stored in HSS and V2X Control Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.3 V2X Authorization data
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.3.1 V2X-Permission-in-VPLMN
The V2X-Permision-VPLMN is part of the V2X authorization data and is specified in 3GPP TS 29.389 [109]. V2X-Permission-in-VPLMN is permanent data conditionally stored in V2X Control Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.3.2 V2X-Application-Server
The V2X-Application-Server is part of the V2X authorization data and is specified in 3GPP TS 29.389 [109]. V2X-Application-Server is permanent data conditionally stored in V2X Control Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.3.3 PC5-RAT-Type
The PC5-RAT-Type is part of the V2X authorization data and is specified in 3GPP TS 29.389 [109]. PC5-RAT-Type is permanent data conditionally stored in HSS and V2X Control Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.4 V2X Control Function Identity
V2X Function Identity is specified in 3GPP TS 29.388 [108]. The V2X Control Function Identity is temporary subscriber data and is conditionally stored in the HSS.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.5 V2X Subscription data for the network scheduled NR sidelink communication
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.5.1 V2X-Permission
The V2X-Permision is part of the V2X Subscription data information for the network scheduled NR sidelink communication and is specified in 3GPP TS 29.272 [81]. V2X-Permission is permanent data conditionally stored in HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.5.2 UE-PC5-AMBR
The UE-PC5-AMBR is part of the V2X Subscription data information for the network scheduled NR sidelink communication and is specified in 3GPP TS 29.272 [81]. UE-PC5-AMBR is permanent data conditionally stored in HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.5.3 V2X-PC5-Allowed-PLMN
The V2X-PC5-Allowed-PLMN is part of the V2X Subscription data and is specified in 3GPP TS 29.388 [108]. V2X-PC5-Allowed-PLMN is permanent data conditionally stored in HSS and V2X Control Function.
539f847bb6cd6c0ba766caacc29710d4
23.008
3.16.5.4 UE-PC5-QoS
The UE-PC5-QoS is part of the V2X Subscription data information for the network scheduled NR sidelink communication and is specified in 3GPP TS 29.272 [81]. UE-PC5-AMBR is permanent data conditionally stored in HSS and MME.
539f847bb6cd6c0ba766caacc29710d4
23.008
4 Summary of data stored in location registers
Table 5.1 gives an overview of data stored in location registers for non-GPRS Network Access Mode (CS). Table 5.2 shows the data stored in the location registers, in the Gn/Gp-SGSN and in the GGSN for GPRS Network Access Mode. Tables 5.2A-1 show the data stored in the location registers, in the SGSN, S4-SGSN, MME, S-GW...
539f847bb6cd6c0ba766caacc29710d4
23.008
5 Accessing subscriber or PSI data
It shall be possible to retrieve or store subscriber data concerning a specific MS from the HSS by use of each of the following references: - International Mobile Subscriber Identity (IMSI); - Mobile Station ISDN Number (MSISDN). It shall be possible to retrieve CSG subscriber data concerning a specific roaming MS from...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.1 CS Network Access Mode Data Storage
Table 5.1: Overview of data stored for CS Network Access Mode PARAMETER CLAUSE HLR VLR TYPE IMSI 2.1.1.1 M M P Network Access Mode 2.1.1.2 M - P International MS ISDN number 2.1.2 C C P multinumbering MSISDNs 2.1.3 C - P Basic MSISDN indicator 2.1.3.1 C - P MSISDN-Alert indicator 2.1.3.2 C - P TMSI 2.1.4 - C T LMSI 2.1...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.2 PS Network Access Mode Storage (GPRS)
Table 5.2: Overview of data used for PS Network Access Mode (GPRS) PARAMETER Clause HLR VLR Gn/Gp-SGSN GGSN TYPE IMSI 2.1.1.1 M M C C P Network Access Mode 2.1.1.2 M - C note1 - P IMSI Unauthenticated indicator 2.1.1.3 - - C C T International MS ISDN number 2.1.2 C C C C P multinumbering MSISDNs 2.1.3 C - - - P Basic M...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.3 IP Multimedia Service Data Storage
Table 5.3: Overview of IMS subscriber data used for IP Multimedia services PARAMETER Clause HSS S-CSCF IM-SSF AS TYPE Service Centre Address 2.4.23 C - - C P Private User Identity 3.1.1 M M - - P Public User Identity 3.1.2 M M - - P Barring Indication 3.1.3 M M - - P List of authorized visited network identifiers 3.1.4...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.4 Generic Authentication Architecture Service Data Storage
Table 5.4: Overview of data used for GAA services PARAMETER Clause HSS BSF NAF TYPE Private User Identity 3.1.1 M M C P GAA Service Type 3.10.1 M M M P GAA Service Identifier 3.10.2 M M M P GBA User Security Settings 3.10.3 M M - P User Security Setting 3.10.4 M M M P User Public Identity 3.10.5 M M M P GAA Authorizati...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.5 I-WLAN Service Data Storage
NOTE: The WLAN Network Selection and WLAN/3GPP Radio Interworking features supersede the I-WLAN feature from Rel-12 onwards, therefore all I-WLAN subscriber data specified in the present Clause are no longer maintained. Table 5.5: Overview of data used for I-WLAN services PARAMETER Clause HSS 3GPP AAA Server 3GPP AAA P...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.6 MBMS Storage (EPS)
Table 5.6-1: Overview of data used for MBMS (EPS) PARAMETER Clause SGSN MME MBMS GW BM-SC TYPE MBMS GW F-TEID for Sm(Control Plane) 2.22.1 - C C - T MBMS GW F-TEID for Sn(Control Plane) 2.22.2 C - C - T Temporary Mobile Group Identity 2.22.3 C C C C P MBMS Flow Identifier 2.22.4 C C C C P MBMS IP Multicast Distribution...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.7 VPLMN Autonomous CSG Roaming Service Data Storage
Table 5.7-1: Overview of data used for VPLMN Autonomous CSG Roaming Service PARAMETER Clause CSS MME S4-SGSN Gn/Gp-SGSN VLR TYPE IMSI 2.1.1.1 M C C M M P International MS ISDN number 2.1.2 C C C C C P VLR Number 2.4.5 M - - - - T SGSN Number 2.4.8.1 M - - - - T CSS Number 2.4.25 - - - C C T VPLMN Closed Subscriber Grou...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.8 Proximity Services (ProSe) Data Storage
Table 5.8-1: Overview of data for Proximity Services PARAMETER Clause HSS SLP MME ProSe Function ProSe Application Server TYPE IMSI 2.1.1.1 M C C C - P MSISDN 2.1.2 C C C C - P ProSe-Permission 3.13.2.1 C - C C - P PLMN-Allowed-ProSe 3.13.2.2 C - C C - P Application layer user ID 3.13.3 - - - C C P EPC ProSe User ID 3....
539f847bb6cd6c0ba766caacc29710d4
23.008
5.9 Architecture Enhancements for Service Exposure storage (AESE)
Table 5.9-1: Overview of data used for AESE PARAMETER Clause HSS MME SGSN SCEF TYPE International MS ISDN number 2.1.2 C C C C P External Identifier Set 2.1.10 C - - C P SCEF-Reference-ID 3.14.2 C C C C T SCEF-ID 3.14.3 C C C C P Monitoring-Type 3.14.4 C C C C P Maximum-Number-of-Reports 3.14.5 C C C C P UE-Reachabilit...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.10 Data related to Cellular IoT Control Plane Optimizations
Table 5.10-1: Overview of data used for CIoT PARAMETER Clause HSS MME SGSN SGW PGW SCEF TYPE IMSI 2.1.1.1 C C C - - C P MSISDN 2.1.2 C C C - - C P External Identifier set 2.1.10 C - - - - C P Access Point Name 2.13.6 C C C - - C P EPS Bearer Id 2.13.66 - C C - - C T Acknowledgement-Of-Downlink-NAS-Data-PDUs flag 2.13.1...
539f847bb6cd6c0ba766caacc29710d4
23.008
5.11 V2X Service (V2X) Data Storage
Table 5.11-1: Overview of data for V2X Service PARAMETER Clause HSS SLP MME V2X Control Function TYPE IMSI 2.1.1.1 M C C C P MSISDN 2.1.2 C C C C P V2X-Permission 3.16.2.1 C - C - P UE-PC5-AMBR 3.16.2.2 C - C - P V2X-PC5-Allowed-PLMN 3.16.2.3 C - - C P V2X-Permission-in-VPLMN 3.16.3.1 - - - C P V2X-Application-Server 3...
c5195074c429803154bc8b9cf2be11b9
23.015
1 Scope
The network feature Operator Determined Barring (ODB) allows a network operator or service provider to regulate access by subscribers to services (Circuit/Packet Oriented and Interworking WLAN), by the barring of certain categories of incoming or outgoing calls/ Packet Oriented Services or of roaming. Operator Determin...
c5195074c429803154bc8b9cf2be11b9
23.015
1.1 Normative references
The following documents contain provisions which, through reference in this text, constitute provisions of the present document. - References are either specific (identified by date of publication, edition number, version number, etc.) or non‑specific. - For a specific reference, subsequent revisions do not apply. - Fo...
c5195074c429803154bc8b9cf2be11b9
23.015
1.2 Definitions and abbreviations
Abbreviations used in this specification are listed in 3GPP TS 21.905.
c5195074c429803154bc8b9cf2be11b9
23.015
2 Method of realisation
The entities which control the application of Operator Determined Barring (ODB), and the methods used, are described in this clause. Two cases are considered for each type of barring: the effect of administrative action in the HLR to modify the application of the category to a particular subscription, and the effect of...
c5195074c429803154bc8b9cf2be11b9
23.015
2.1 Barring of Outgoing Calls or Mobile Originated Short Messages
Barring of outgoing calls or mobile originated short messages includes the categories "outgoing calls" and "outgoing premium rate calls" defined in 3GPP TS 22.041 [2], and the "operator specific barring" category where this is defined by the PLMN operator to apply to outgoing calls or mobile originated short messages.
c5195074c429803154bc8b9cf2be11b9
23.015
2.1.1 Application or Change of Barring in the HLR
If barring of outgoing calls or mobile originated short messages is applied to a subscription (or existing barring of outgoing calls or mobile originated short messages is modified or removed) by administrative action in the HLR, the HLR will update the subscription information accordingly, and transfer the updated sub...
c5195074c429803154bc8b9cf2be11b9
23.015
2.1.2 Invocation of Barring
Barring of outgoing calls or mobile originated short messages is invoked in the VLR. If the VLR receives a request for subscription information for an outgoing call or mobile originated short message which is prohibited by Operator Determined Barring, the VLR will return a negative response to the request for subscript...