8.5.3.2.2.1.3 Test purpose
The purpose of this test is to verify the requirement for the uplink synchronization control during intra-frequency handover in CELL_DCH state in minimum requirement .
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.1.4 Initial conditions
The test parameters are given in Table 8.5.3.2.2.2 and 8.5.3.2.2.3 as below. The test consists of three successive time periods, with a time duration of T1, T2 and T3 respectively. At the start of time duration T1, the UE may not have any timing information of cell 2. UTRAN shall send a Physical Channel reconfiguration with activation time "now" at the beginning of T3 with a new active cell, cell 2, after the UE has reported event 1G. The starting point of T3 is defined as the end of the last TTI containing the physical channel reconfiguration message. Table 8.5.3.2.2.2: General test parameters for intra-frequency handover Parameter Unit Value Comment DPCH parameters DL and UL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2.2 and A.2.1.2 Power Control On Target quality value on DPCH BLER 0.01 Initial conditions Active cell Cell 1 In the case of multi-frequency network, the UE has a RRC connection on the primary frequency in cell 1. Neighbouring cell Cell 2 Final condition Active cell Cell 2 In the case of multifrequency network, UE will handover to the primary frequency in cell 2. O dB 0 cell-individual-offset The value shall be used for all cells in the test. Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 T1 s 5 T2 s 5 T3 s 5 Table 8.5.3.2.2.3: Cell specific test parameters for intra-frequency handover Parameter Unit Cell 1 Timeslot Number 0 DwPTS 5 T1 T2 T3 T1 T2 T3 T1 T2 T3 UTRA RF Channel Number(Note3) Channel 1 PCCPCH_Ec/Ior dB -3 n.a. DwPCH_Ec/Ior 0 DPCH_Ec/Ior dB n.a. n.a. Note1 n.a. OCNS_Ec/Ior dB -3 Note2 dB 3 3 3 dBm/1.28 MHz -70 PCCPCH_RSCP dBm -70 n.a. n.a. Propagation Condition AWGN Parameter Unit Cell 2 Timeslot Number 0 DwPTS 5 T1 T2 T3 T1 T2 T3 T1 T2 T3 UTRA RF Channel Number(Note3) Channel 1 PCCPCH_Ec/Ior dB -3 n.a. DwPCH_Ec/Ior 0 DPCH_Ec/Ior dB n.a. n.a. n.a. Note1 OCNS_Ec/Ior dB -3 Note2 dB -Inf. 6 -Inf. 6 -Inf. 6 dBm/1.28 MHz -70 PCCPCH_RSCP dBm -Inf. -67 n.a. n.a. Propagation Condition AWGN Note 1: The DPCH level is controlled by the power control loop Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior . Note 3: In the case of multi-frequency network, the UTRA RF Channel Number is the primary frequency’s channel number.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.1.5 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.4. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 5 seconds, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 1G. 7) SS shall transmit a PHYSICAL CHANNEL RECONFIGURATION message with activation time “now”. 8) After 5 seconds, the SS shall switch the power settings from T2 to T3 9) The UE transmits the UL DPCH to cell 2 less than 1 s from the beginning of time period T3 and UTRAN measures the initial uplink synchronization timing position of the first UL DPCH on cell2 and compares it with the desired position. If the timing deviation is less than the accuracy requirement as specified in Table 8.5.3.2.2.4, the number of successful tests is increased by one. And UE shall transmit a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the UL DCCH of cell 2. 10) After 5 seconds, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 11) Repeat step 1-10 until the confidence level according to annex F.6.2 is achieved. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE (Note 1) -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE (Note 1) -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 2 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 1 -Intra-frequency event identity Event 1G -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency Not Present -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 2) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: The SFN-CFN observed time difference is calculated from the OFF and Tm parameters contained in the IE "Cell synchronisation information ", TS 25.331, clause 10.3.7.6. According to TS 25.331, 8.6.7.7, this IE is included in MEASUREMENT REPORT if IE "Cell synchronisation information reporting indicator" in IE "Cell reporting quantities" TS 25.331, clause 10.3.7.5 is set to TRUE in MEASUREMENT CONTROL. Note 2: Reporting interval = 0 ms means no periodical reporting PHYSICAL CHANNEL RECONFIGURATION message (step 7): Information Element Value/Remark Message Type UE Information Elements -RRC transaction identifier 0 -Integrity check info Not Present -Integrity protection mode info Not Present -Ciphering mode info Not Present -Activation time At T3 -New U-RNTI Not Present -New C-RNTI Not Present -RRC State Indicator CELL_DCH -UTRAN DRX cycle length coefficient Not Present CN Information Elements -CN Information info Not Present UTRAN mobility information elements -URA identity Not Present RB information elements -Downlink counter synchronisation info Not Present -RB with PDCP information list Not Present -RB with PDCP information Not Present PhyCH information elements -Frequency info (10.3.6.36) -CHOICE mode TDD -UARFCN (Nt) Same UARFCN as used for cell 2 Uplink radio resources -Maximum allowed UL TX power 30 dBm -CHOICE channel requirement Uplink DPCH info -Uplink DPCH info (10.3.6.88) -Uplink DPCH power control info (10.3.6.91) -CHOICE mode TDD -TDD 1,28 Mcps TDD -UL target SIR Not Present -CHOICE UL OL PC info Individually signalled -CHOICE TDD option --1,28 Mcps TDD 1 -TPC step size 1 -CHOICE mode TDD -Uplink timing advance control (10.3.6.96) -CHOICE Timing Advance Disabled -UL CCTrCH list 1 -UL Target SIR 9 dB -Time Info (10.3.6.83) -Activation Time now -Duration Infinite -Common timeslot info Not Present -Uplink DPCH timeslots and codes (10.3.6.94) -Dynamic SF Usage False -First individual timeslot info (10.3.6.37) -Timeslot Number (10.3.6.84) -CHOICE TDD option 1,28 Mcps -Timeslot number 2 -TFCI existence True -Midamble shift and burst type (10.3.6.41) -Choice TDD option 1,28 Mcps -Midamble Allocation Mode Default -Midamble configuration 16 -Midamble shift Not present -CHOICE TDD option 1,28 Mcps -Modulation QPSK - SS-TPC Symbols -Additional TPC-SS Symbols -First timeslot code list 1 -Channelisation code 8/1 -Choice more timeslots No more timeslots Downlink radio resources -CHOICE mode TDD -Downlink information common for all radio links (10.3.6.24) -Downlink DPCH info common for all RL (10.3.6.18) -Timing indicator Initialise -CFN-targetSFN frame offset Not Present -Downlink DPCH power control information (10.3.6.23) -CHOICE mode TDD -TPC Step size 1 dB -CHOICE mode TDD -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps - TSTD indicator (10.3.6.85a) TRUE -Default DPCH Offset Value (10.3.6.16) 0 -Downlink information per radio link list 1 -Downlink information for each radio link (10.3.6.27) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps TSTD indicator TRUE -Cell parameters ID 0 -SCTD indicator False -Downlink DPCH info for each RL (10.3.6.21) -CHOICE mode TDD -DL CCTrCH list 1 -TFCS ID Not Present -Time Info (10.3.6.83) -Activation Time now -Duration Infinite -Common timeslot info Not Present -Downlink DPCH timeslots and codes (10.3.6.32) -First individual timeslot info (10.3.6.37) -Timeslot Number (10.3.6.84) -CHOICE TDD option 1,28 Mcps -Timeslot number 5 -TFCI existence True -Midamble shift and burst type (10.3.6.41) -CHOICE TDD option 1,28 Mcps -Midamble Allocation Mode Default -Midamble configuration 16 -Midamble shift Not present -CHOICE TDD option 1,28 Mcps -Modulation QPSK -SS-TPC Symbols -Additional TPC-SS Symbols -First timeslot channelisation codes (10.3.6.17) -CHOICE codes representation Consecutive codes -First channelisation code 16/1 -Last channelisation code 16/2 -CHOICE more timeslots No more timeslots -SCCPCH information for FACH (10.3.6.70) Not Present MEASUREMENT REPORT message for Intra frequency test cases This message is common for all intra frequency test cases in clause 8.7 and is described in Annex I.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.1.6 Test requirements
The UE shall not exceed the accuracy requirements as Table 8.5.3.2.2.4. Table 8.5.3.2.2.4: Uplink synchronisation control accuracy requirements Parameter Unit Accuracy [chip] Conditions Io [dBm/ 1.28 MHz] Uplink synchronization control during handover chip +/- 0.5 -94...-50 The rate of correct handovers observed during repeated tests shall be at least 90% with a confidence level of 95%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.2 Scenario 2: Handover to inter-frequency cell
This test case is applicable for UE handovers in single frequency network and UE handovers from primary frequency to secondary frequency in multi-frequency network.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.2.1 Definition and applicability
The closed loop uplink synchronisation control uses layer 1 symbols (SS commands) for DPCH and PUSCH. After establishment of the uplink synchronisation, NodeB and UE start to use the closed loop UL synchronisation control procedure. This procedure is continuous during connected mode. During a handover the UE shall transmit in the new cell with timing advance TA adjusted by the relative timing difference t between the new and the old cell if indicated by higher layers: TAnew = TAold + 2t. TAnew is the timing advance of the new cell. TAold is the timing advance of the old cell, t is the relative timing difference between the new and the old cell, which is measured by UE as SFN-SFN observed time difference type 2. The uplink synchronization accuracy during handover is defined as timing deviation between the initial actual uplink synchronization position and the desired position of the first uplink DPCH on the target cell. The requirements and this test apply to all types of 1.28 Mcps TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.2.2 Minimum requirement
The UE shall not exceed the accuracy requirements as Table 8.5.3.2.2.5. Table 8.5.3.2.2.5: Uplink synchronisation control accuracy requirements Parameter Unit Accuracy [chip] Conditions Io [dBm/ 1.28 MHz] Uplink synchronization control during handover chip +/- 0.5 -94...-50 The rate of correct uplink synchronisation control observed during repeated tests shall be at least 90% with a confidence level of 95%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.2.4 Initial conditions
The test parameters are given in Table 8.5.3.2.2.6 and 8.5.3.2.2.7 as below. The test consists of three successive time periods, with a time duration of T1, T2 and T3 respectively. At the start of time duration T1, the UE may not have any timing information of cell 2. UTRAN shall send a Physical Channel reconfiguration with activation time "now" at the beginning of T3 with a new active cell, cell 2, after the UE has reported event 1G. The starting point of T3 is defined as the end of the last TTI containing the physical channel reconfiguration message. Table 8.5.3.2.2.6: General test parameters for inter-frequency handover Parameter Unit Value Comment DPCH parameters DL and UL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2.2 and A.2.1.2 Power Control On Target quality value on DPCH BLER 0.01 Initial conditions Active cell Cell 1 The UE has a RRC connection on the secondary frequency in cell 1. Neighbour cell Cell 2 Final conditions Active cell Cell 2 The UE will handover to the primary frequency in cell 2. Threshold non used frequency dBm -75 Absolute RSCP threshold for event 2C O dB 0 cell-individual-offset The value shall be used for all cells in the test. Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 6 TDD neighbours on Channel 2 T1 s 5 T2 s 10 T3 s 5 Table 8.5.3.2.2.7: Cell Specific parameters for inter-frequency handover Parameter Unit Cell 1 Timeslot Number 0 DwPTS 5 T1 T2 T3 T1 T2 T3 T1 T2 T3 UTRA RF Channel Number(Note 3) Channel 1 UTRA RF Channel Number(Note 4) Channel 2 PCCPCH_Ec/Ior dB -3 n.a. DwPCH_Ec/Ior 0 DPCH_Ec/Ior dB n.a. n.a. Note1 n.a. OCNS_Ec/Ior dB -3 Note2 dB 3 3 3 dBm/1.28 MHz -70 PCCPCH_RSCP dBm -70 n.a. n.a. Propagation Condition AWGN Parameter Unit Cell 2 Timeslot Number 0 DwPTS 5 T1 T2 T3 T1 T2 T3 T1 T2 T3 UTRA RF Channel Number(Note 3) Channel 1 UTRA RF Channel Number(Note 4) Channel 2 PCCPCH_Ec/Ior dB -3 n.a. DwPCH_Ec/Ior 0 DPCH_Ec/Ior dB n.a. n.a. n.a. Note1 OCNS_Ec/Ior dB -3 Note2 dB -Inf. 4 -Inf. 4 -Inf. 4 dBm/1.28 MHz -70 PCCPCH_RSCP dBm -Inf. -69 n.a. n.a. Propagation Condition AWGN Note 1: The DPCH level is controlled by the power control loop Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior . Note3: The UTRA RF Channel Number is the primary frequency’s channel number. Note4: The UTRA RF Channel Number is the secondary frequency’s channel number.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.2.5 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.4. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 5 seconds, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 1G. 7) SS shall transmit a PHYSICAL CHANNEL RECONFIGURATION message with activation time “now”. 8) After 10 seconds, the SS shall switch the power settings from T2 to T3 9) The UE transmits the UL DPCH to cell 2 less than 1 s from the beginning of time period T3 and UTRAN measures the initial uplink synchronization timing position of the first UL DPCH on cell2 and compares it with the desired position. If the timing deviation is less than the accuracy requirement as specified in Table 8.5.3.2.2.4, the number of successful tests is increased by one. And UE shall transmit a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the UL DCCH of cell 2. 10) After 5 seconds, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 11) Repeat steps1-10 until the confidence level according to annex F.6.2 is achieved. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message, event 2C (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE (Note 1) -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE (Note 1) -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 2 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 1 -Intra-frequency event identity Event 1G -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency Not Present -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 2) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: The SFN-CFN observed time difference is calculated from the OFF and Tm parameters contained in the IE "Cell synchronisation information ", TS 25.331, clause 10.3.7.6. According to TS 25.331, 8.6.7.7, this IE is included in MEASUREMENT REPORT if IE "Cell synchronisation information reporting indicator" in IE "Cell reporting quantities" TS 25.331, clause 10.3.7.5 is set to TRUE in MEASUREMENT CONTROL. Note 2: Reporting interval = 0 ms means no periodical reporting PHYSICAL CHANNEL RECONFIGURATION message (step 7): Information Element Value/Remark Message Type UE Information Elements -RRC transaction identifier 0 -Integrity check info Not Present -Integrity protection mode info Not Present -Ciphering mode info Not Present -Activation time At T3 -New U-RNTI Not Present -New C-RNTI Not Present -RRC State Indicator CELL_DCH -UTRAN DRX cycle length coefficient Not Present CN Information Elements -CN Information info Not Present UTRAN mobility information elements -URA identity Not Present RB information elements -Downlink counter synchronisation info Not Present -RB with PDCP information list Not Present -RB with PDCP information Not Present PhyCH information elements -Frequency info (10.3.6.36) -CHOICE mode TDD -UARFCN (Nt) Same UARFCN as used for cell 2 Uplink radio resources -Maximum allowed UL TX power 30 dBm -CHOICE channel requirement Uplink DPCH info -Uplink DPCH info (10.3.6.88) -Uplink DPCH power control info (10.3.6.91) -CHOICE mode TDD -TDD 1,28 Mcps TDD -UL target SIR Not Present -CHOICE UL OL PC info Individually signalled -CHOICE TDD option --1,28 Mcps TDD 1 -TPC step size 1 -CHOICE mode TDD -Uplink timing advance control (10.3.6.96) -CHOICE Timing Advance Disabled -UL CCTrCH list 1 -UL Target SIR 9 dB -Time Info (10.3.6.83) -Activation Time now -Duration Infinite -Common timeslot info Not Present -Uplink DPCH timeslots and codes (10.3.6.94) -Dynamic SF Usage False -First individual timeslot info (10.3.6.37) -Timeslot Number (10.3.6.84) -CHOICE TDD option 1,28 Mcps -Timeslot number 2 -TFCI existence True -Midamble shift and burst type (10.3.6.41) -Choice TDD option 1,28 Mcps -Midamble Allocation Mode Default -Midamble configuration 16 -Midamble shift Not present -CHOICE TDD option 1,28 Mcps -Modulation QPSK - SS-TPC Symbols -Additional TPC-SS Symbols -First timeslot code list 1 -Channelisation code 8/1 -Choice more timeslots No more timeslots Downlink radio resources -CHOICE mode TDD -Downlink information common for all radio links (10.3.6.24) -Downlink DPCH info common for all RL (10.3.6.18) -Timing indicator Initialise -CFN-targetSFN frame offset Not Present -Downlink DPCH power control information (10.3.6.23) -CHOICE mode TDD -TPC Step size 1 dB -CHOICE mode TDD -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps - TSTD indicator (10.3.6.85a) TRUE -Default DPCH Offset Value (10.3.6.16) 0 -Downlink information per radio link list 1 -Downlink information for each radio link (10.3.6.27) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps TSTD indicator TRUE -Cell parameters ID 0 -SCTD indicator False -Downlink DPCH info for each RL (10.3.6.21) -CHOICE mode TDD -DL CCTrCH list 1 -TFCS ID Not Present -Time Info (10.3.6.83) -Activation Time now -Duration Infinite -Common timeslot info Not Present -Downlink DPCH timeslots and codes (10.3.6.32) -First individual timeslot info (10.3.6.37) -Timeslot Number (10.3.6.84) -CHOICE TDD option 1,28 Mcps -Timeslot number 5 -TFCI existence True -Midamble shift and burst type (10.3.6.41) -CHOICE TDD option 1,28 Mcps -Midamble Allocation Mode Default -Midamble configuration 16 -Midamble shift Not present -CHOICE TDD option 1,28 Mcps -Modulation QPSK -SS-TPC Symbols -Additional TPC-SS Symbols -First timeslot channelisation codes (10.3.6.17) -CHOICE codes representation Consecutive codes -First channelisation code 16/1 -Last channelisation code 16/2 -CHOICE more timeslots No more timeslots -SCCPCH information for FACH (10.3.6.70) Not Present MEASUREMENT REPORT message for Inter frequency test cases This message is common for all inter frequency TDD test cases in clause 8.7 and is described in Annex I.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.2.2.2.6 Test requirements
The UE shall not exceed the accuracy requirements as Table 8.5.3.2.2.8. Table 8.5.3.2.2.8: Uplink synchronisation control accuracy requirements Parameter Unit Accuracy [chip] Conditions Io [dBm/ 1.28 MHz] Uplink synchronization control during handover chip +/- 0.5 -94...-50 The rate of correct handovers observed during repeated tests shall be at least 90% with a confidence level of 95%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.5.3.3 7.68 Mcps TDD option
Void.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6 UE Measurements Procedures
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1 TDD intra frequency measurements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1 Event 1G triggered reporting in AWGN propagation conditions
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.1 Definition and applicability
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.1.1 3,84 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (3,84 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.1.2 1,28 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the 1.28 Mcps option TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.1.3 7,68 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (7,68 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.2 Minimum requirement
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.2.1 3,84 Mcps TDD Option
The UE shall be able to identify a new detectable intra-frequency TDD cell belonging to the monitored set within Tidentify intra ms, where Tidentify intra = 800 ms. When L3 filtering is used, an additional delay can be expected. In CELL_DCH state, the UE shall be capable of performing P-CCPCH RSCP measurements for Xmeasurement intra identified intra-frequency TDD cells of the monitored set with a measurement period for intra-frequency P-CCPCH RSCP measurements Tmeasurement period intra, where Xmeasurement intra = 6 (cells) Tmeasurement period intra = 200 ms The UE physical layer shall be capable of reporting these measurements to higher layers with the measurement period Tmeasurement period intra. If the UE has identified more than Xmeasurement intra intra-frequency TDD cells, the UE shall perform measurements of all identified cells but the reporting rate of P-CCPCH RSCP measurements of cells from the UE physical layer to higher layers may be decreased.. The measurement accuracy for all measured cells shall be as specified in the section 9. The normative reference for this requirement is TS 25.123 [2] clauses 8.1.2.2.1, 8.1.2.2.2 and A.8.1.1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.2.2 1,28 Mcps TDD Option
The UE shall be able to identify a new intra frequency TDD cell belonging to the monitored set within ms Tbasic_identify_TDD, intra = 800 ms. This is the time period used in the intra frequency equation where the maximum allowed time for the UE to identify a new TDD cell is defined. NPeriod,Intra: = 40 Number of subframes in TMeasurement_Period, Intra. NIntra : This is the minimum number of sub-frame in that the period of TS0, DwPTS and main guard period is available for intra frequency measurements, during the measurement period. TMeasurement_Period, Intra = 200 ms. The measurement period for Intra frequency P-CCPCH RSCP measurements. If a cell belonging to monitored set has been detectable at least for the time period Tidentify_intra and then enters or leaves the reporting range, the event triggered measurement reporting delay shall be less than 200ms when the L3 filter has not been used and the UE P-CCPCH measurement capabilities of Section 8.1A.2.2.2 in [2] are valid. The event triggered measurement reporting delay on cells not belonging to monitored set, measured without L3 filtering, shall be less than the above defined Tidentify detected set.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.2.3 7,68 Mcps TDD Option
The UE shall be able to identify a new detectable intra-frequency TDD cell belonging to the monitored set within Tidentify intra ms, where Tidentify intra = 800 ms. When L3 filtering is used, an additional delay can be expected. In CELL_DCH state, the UE shall be capable of performing P-CCPCH RSCP measurements for Xmeasurement intra identified intra-frequency TDD cells of the monitored set with a measurement period for intra-frequency P-CCPCH RSCP measurements Tmeasurement period intra, where Xmeasurement intra = 6 (cells) Tmeasurement period intra = 200 ms The UE physical layer shall be capable of reporting these measurements to higher layers with the measurement period Tmeasurement period intra. If the UE has identified more than Xmeasurement intra intra-frequency TDD cells, the UE shall perform measurements of all identified cells but the reporting rate of P-CCPCH RSCP measurements of cells from the UE physical layer to higher layers may be decreased.. The measurement accuracy for all measured cells shall be as specified in the section 9. The normative reference for this requirement is TS 25.123 [2] clauses 8.1B.2.2.1, 8.1B.2.2.2 and A.8.1.1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.3 Test purpose
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.3.1 3,84 Mcps TDD Option
To verify that the UE meets the minimum requirement.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.3.2 1,28 Mcps TDD Option
To verify the UE meets the minimum requirements.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.3.3 7,68 Mcps TDD Option
To verify the UE meets the minimum requirements.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.4.1 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.4.1.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Table 8.6.1.1.1 and 8.6.1.1.2. The test consists of three successive time periods, with time durations of T1, T2 and T3 respectively. Three cells shall be present in the test, cell 1 being the serving cell and cell 2 and cell 3 being neighbour cells on the used frequency. All cells shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 1G shall be used, and that P-CCPCH RSCP shall be reported together with Event 1G. The Measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in [9]. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The DL DPCH shall be transmitted in timeslot 2 and the UL DPCH shall be transmitted in timeslot 10. The TTI of the uplink DCCH shall be 20ms. Table 8.6.1.1.1: General test parameters for Event 1G triggered reporting in AWGN propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 Neighbour cell Cell 2, Cell 3 Final condition Active cell Cell 1 O dB 0 Cell individual offset. This value shall be used for all cells in the test. Hysteresis dB 0 Time to Trigger ms 0 Threshold used frequency dBm -70 Applicable for Event 1G Filter coefficient 0 Monitored cell list size 12 TDD neighbours on Channel 1 T1 s 6 T2 s 6 T3 s 6 Table 8.6.1.1.2: Cell specific parameters for Event 1G triggered correct reporting in AWGN propagation condition Parameter Unit Cell 1 Cell 2 Cell 3 T1 T2 T3 T1 T2 T3 T1 T2 T3 DL timeslot number 0 0 0 UTRA RF Channel Number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 10 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 dB 7 5 5 7 -Inf -Inf 7 PCCPCH RSCP dBm -66 -68 -68 -66 -Inf -Inf -66 dBm / 3,84 MHz -70 Propagation Condition AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.4.1.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 6 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 1G for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 240 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 6 seconds from the beginning of T2, the SS shall switch the power settings from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 1G for cell 3. The measurement reporting delay from the beginning of T3 shall be less than 840 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 9) After 6 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 10) Repeat steps 1-9 [TBD] times. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 1 -Intra-frequency event identity Event 1G -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency Not Present -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1G -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of Cell 2 MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of Cell 3 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1G -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of Cell 3
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.4.2 1,28 Mcps TDD Option
Test environment : normal; see clauses G.2.1 and G.2.2. Frequencies to be tested : mid range ;see clauses G.2.4. The test parameters are given in Table 8.6.1.1.4A and 8.6.1.1.4B below. The test consists of three successive time periods, with time durations of T1, T2 and T3 respectively. Three cells shall be present in the test, cell 1 being the serving cell and cell 2 and cell 3 being neighbour cells on the used frequency. All cells shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 1G shall be used, and that P-CCPCH RSCP shall be reported together with Event 1G reporting. The Measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in [9]. The cell specific test parameters are given in Table 8.6.1.1B below. The TTI of the uplink DCCH shall be 40ms. Table 8.6.1.1.4A: General test parameters for Event 1G triggered reporting in AWGN propagation condition 1,28Mcps option Parameter Unit Value Comment DPCH parameters active cell DL and UL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A. The DPCH is located in an other timeslot than 0 Power Control On Target quality value on DTCH BLER 0.01 Active cell Cell 1 Neighbour cell Cell 2, Cell 3 O DB 0 Cell individual offset. This value shall be used for all cells in the test. Hysteresis DB 0 Time to Trigger Ms 0 Filter coefficient 0 Monitored cell list size 12 TDD neighbours on Channel 1 T1 S 6 T2 S 6 T3 S 6 Table 8.6.1.1.4B: Cell specific parameters for Event 1G triggered correct reporting in AWGN propagation condition 1,28 Mcps option Parameter Unit Cell 1 Cell 2 Cell 3 DL timeslot number 0 DwPTS 0 DwPTS 0 DwPTS T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 UTRA RF Channel Number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 DwPCH_Ec/Ior dB 0 0 0 OCNS_Ec/Ior dB -3 -3 -3 dB 7 4 7 4 4 7 -Inf 4 7 -Inf -Inf 7 -Inf 7 PCCPCH RSCP dBm -66 -69 -69 -66 -Inf -Inf -66 dBm / 1,28 MHz -70 Propagation Condition AWGN NOTE: The DPCH of all cells are located in a timeslot other than 0. 1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 6 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 1G for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 280 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 7) After 6 seconds from the beginning of T2, the SS shall switch the power settings from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 1G for cell 3. The measurement reporting delay from the beginning of T3 shall be less than 880 ms. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 9) After 6 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 10) Repeat steps 1-9 until the confidence level according to annex F.6.2 is achieved. Specific Message Contents All messages indicated above shall use the default message content in clause 9 of 34.108 [3], with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 1 -Intra-frequency event identity Event 1G -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency Not Present -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1G -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD Option 1.28 Mcps TDD -Cell parameters ID Set to Cell parameters ID of Cell 2 MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of Cell 3 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1G -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD Option 1.28 Mcps TDD -Cell parameters ID Set to Cell parameters ID of Cell 3
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.4.3 7,68 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.4.3.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Table 8.6.1.1.4.3.1.1 and 8.6.1.1.4.3.1.2. The test consists of three successive time periods, with time durations of T1, T2 and T3 respectively. Three cells shall be present in the test, cell 1 being the serving cell and cell 2 and cell 3 being neighbour cells on the used frequency. All cells shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 1G shall be used, and that P-CCPCH RSCP shall be reported together with Event 1G. The Measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in [9]. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The DL DPCH shall be transmitted in timeslot 2 and the UL DPCH shall be transmitted in timeslot 10. The TTI of the uplink DCCH shall be 20ms. Table 8.6.1.1.4.3.1.1: General test parameters for Event 1G triggered reporting in AWGN propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 Neighbour cell Cell 2, Cell 3 Final condition Active cell Cell 1 O dB 0 Cell individual offset. This value shall be used for all cells in the test. Hysteresis dB 0 Time to Trigger ms 0 Threshold used frequency dBm -70 Applicable for Event 1G Filter coefficient 0 Monitored cell list size 12 TDD neighbours on Channel 1 T1 s 6 T2 s 6 T3 s 6 Table 8.6.1.1.4.3.1.2: Cell specific parameters for Event 1G triggered correct reporting in AWGN propagation condition Parameter Unit Cell 1 Cell 2 Cell 3 T1 T2 T3 T1 T2 T3 T1 T2 T3 DL timeslot number 0 0 0 UTRA RF Channel Number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 10 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 dB 7 5 5 7 -Inf -Inf 7 PCCPCH RSCP dBm -66 -68 -68 -66 -Inf -Inf -66 dBm / 7,68 MHz -70 Propagation Condition AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.4.3.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 6 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 1G for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 240 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 6 seconds from the beginning of T2, the SS shall switch the power settings from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 1G for cell 3. The measurement reporting delay from the beginning of T3 shall be less than 840 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 9) After 6 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 10) Repeat steps 1-9 until the confidence level according to annex F.6.2 is achieved. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 1 -Intra-frequency event identity Event 1G -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case 2 -Timeslot 0 -Cell parameters ID 0 -SCTD indicator FALSE -W Not Present -Hysteresis 0 dB -Threshold used frequency Not Present -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1G -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case Not present -Cell parameters ID Set to Cell parameters ID of Cell 2 -SCTD indicator FALSE MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of Cell 3 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1G -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case Not Present -Cell parameters ID Set to Cell parameters ID of Cell 3 -SCTD indicator FALSE
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.5 Test requirements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.5.1 3,84 Mcps TDD Option
The UE shall send one Event 1G triggered measurement report for Cell 2 with a measurement reporting delay less than 240ms from the beginning of time period T2. The UE shall send one Event 1G triggered measurement report for Cell 3 with a measurement reporting delay less than 840ms from the beginning of time period T3. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of [FFS]% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.5.2 1,28 Mcps TDD Option
The UE shall send one Event 1G triggered measurement report for Cell 2 with a measurement reporting delay less than 280ms from the beginning of time period T2. The UE shall send one Event 1G triggered measurement report for Cell 3 with a measurement reporting delay less than 880ms from the beginning of time period T3. The UE shall not send any incorrect event triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of 95% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.1.5.3 7,68 Mcps TDD Option
The UE shall send one Event 1G triggered measurement report for Cell 2 with a measurement reporting delay less than 240ms from the beginning of time period T2. The UE shall send one Event 1G triggered measurement report for Cell 3 with a measurement reporting delay less than 840ms from the beginning of time period T3. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of 95% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2 Event 1H and 1I triggered reporting in AWGN propagation condition
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.1 Definition and applicability
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.1.1 3,84 Mcps TDD Option
In the event triggered reporting, the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (3,84 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.1.2 1,28 Mcps TDD Option
The purpose of this test is to verify that the UE makes correct reporting of events 1H (timeslot ISCP below threshold) and 1I (timeslot ISCP above threshold). This test will partly verify the requirements in [2] The requirements and this test apply to all types of 1.28 Mcps TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.1.3 7,68 Mcps TDD Option
In the event triggered reporting, the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (7,68 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.2 Minimum requirement
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.2.1 3,84 Mcps TDD Option
In CELL_DCH state the measurement period for intra frequency Timeslot ISCP measurements on arbitrary DL timeslots, including Beacon timeslots is 400 ms. When no inter frequency measurement is scheduled, the UE shall be capable of performing Timeslot ISCP measurements for a total of 10 different combinations of an arbitrary DL timeslot and an intra-frequency cell, including the current serving cell. The normative reference for this requirement is TS 25.123 [2] clauses 8.1.2.2.2.A and A.8.1.2
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.2.2 1,28 Mcps TDD Option
The UE shall send one event 1I triggered measurement report, with a measurement reporting delay less than 400 ms from the beginning of time period T2 as defined in the test method below. The UE shall send one event 1H triggered measurement report, with a measurement reporting delay less than 400 ms from the beginning of time period T3 as defined in the test method below. The UE shall send one event 1H triggered measurement report, with a measurement reporting delay less than 400 ms from the beginning of time period T4 as defined in the test method below.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.2.3 7,68 Mcps TDD Option
In CELL_DCH state the measurement period for intra frequency Timeslot ISCP measurements on arbitrary DL timeslots, including Beacon timeslots is 400 ms. When no inter frequency measurement is scheduled, the UE shall be capable of performing Timeslot ISCP measurements for a total of 10 different combinations of an arbitrary DL timeslot and an intra-frequency cell, including the current serving cell. The normative reference for this requirement is TS 25.123 [2] clauses 8.1B.2.2.3 and A.8.1.2
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.3 Test purpose
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.3.1 3,84 Mcps TDD Option
To verify that the UE meets the minimum requirement.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.3.2 1,28 Mcps TDD Option
To verify that the UE meets the minimum requirements.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.3.3 7,68 Mcps TDD Option
To verify that the UE meets the minimum requirements.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.4.1 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.4.1.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Tables 8.6.1.2.1, 8.6.1.2.2 and 8.6.1.2.3. The test consists of five successive time periods, with a time duration of T1, T2, T3, T4 and T5 respectively. Two cells shall be present in the test, cell 1 being the current serving cell and cell 2 being a neighbour cell on the used frequency. In the measurement control information it shall be indicated to the UE that event-triggered reporting with event 1H and event 1I shall be used and that Timeslot ISCP and P-CCPCH RSCP shall be reported together with event 1H and 1I. Measurement control information shall be sent to the UE before the beginning of time period T1. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The UL DPCH shall be transmitted in timeslot 10. In addition, timeslots 3 and 4 shall be allocated as DL timeslots. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. Table 8.6.1.2.1: General test parameters for correct event 1H and event 1I reporting in AWGN propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 Neighbour cell Cell 2 Final condition Active cell Cell 1 HCS Not used O dB 0 Cell individual offset. This value shall be used for all cells in the test. Timeslot list cell 1 2, 3, 4 Timeslot numbers in IE "Cell info" for Cell 1 Timeslot list cell 2 4 Timeslot numbers in IE "Cell info" for Cell 2 Threshold used frequency dBm -68 Threshold 1 applicable for event 1H, cell 1 timeslots 2, 4 and cell 2 timeslot 4 Threshold used frequency dBm -73 Threshold 2 applicable for event 1H, cell 1 timeslots 2, 3, 4 and cell 2 timeslot 4 Threshold used frequency dBm -67 Applicable for event 1I, cell 1 timeslots 2, 4 and cell 2 timeslot 4 Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 Cell 2 shall belong to the monitored set T1 s 5 T2 s 5 T3 s 5 T4 s 5 T5 s 5 Table 8.6.1.2.2: Cell 1 specific parameters for correct event 1H and 1I reporting in AWGN propagation condition Parameter Unit Cell 1 T1 T2 T3 T4 T5 T1 T2 T3 T4 T5 UTRA RF Channel Number Channel 1 DL timeslot number 0 2 PCCPCH_Ec/Ior dB -3 n.a. SCH_Ec/Ior dB -9 n.a. SCH_toffset dB 5 n.a. DPCH_Ec/Ior dB n.a. Note 1 OCNS_Ec/Ior dB -3,12 Note 2 dB 4 4 PCCPCH RSCP dBm -69 n.a. dBm / 3,84 MHz -70 Propagation Condition AWGN DL timeslot number 3 4 PCCPCH_Ec/Ior dB n.a. n.a. SCH_Ec/Ior dB n.a. n.a. SCH_toffset dB n.a. n.a. DPCH_Ec/Ior dB n.a. n.a. OCNS_Ec/Ior dB 0 0 dB 3 0 6 PCCPCH RSCP dBm n.a. n.a. dBm / 3,84 MHz -70 Propagation Condition AWGN Note 1: The DPCH level is controlled by the power control loop Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior Table 8.6.1.2.3: Cell 2 specific parameters for correct event 1H and 1I reporting in AWGN propagation condition Parameter Unit Cell 2 T1 T2 T3 T4 T5 T1 T2 T3 T4 T5 UTRA RF Channel Number Channel 1 DL timeslot number 0 2 PCCPCH_Ec/Ior dB -3 n.a. SCH_Ec/Ior dB -9 n.a. SCH_toffset dB 10 n.a. DPCH_Ec/Ior dB n.a. n.a. OCNS_Ec/Ior dB -3,12 0 dB 1 0 6 0 PCCPCH RSCP dBm -72 n.a. dBm / 3,84 MHz -70 Propagation Condition AWGN DL timeslot number 3 4 PCCPCH_Ec/Ior dB n.a. n.a. SCH_Ec/Ior dB n.a. n.a. SCH_toffset dB n.a. n.a. DPCH_Ec/Ior dB n.a. n.a. OCNS_Ec/Ior dB 0 0 dB 3 6 0 PCCPCH RSCP dBm n.a. n.a. dBm / 3,84 MHz -70 Propagation Condition AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.4.1.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 5 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 1I for cell 1 in timeslot 2. The measurement reporting delay from the beginning of T2 shall be less than 480 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 5 seconds from the beginning of T2, the SS shall switch the power settings from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 1H for cell 1 in timeslot 2. The measurement reporting delay from the beginning of T3 shall be less than 480 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 9) After 5 seconds from the beginning of T3, the SS shall switch the power settings from T3 to T4. 10) UE shall transmit a MEASUREMENT REPORT message triggered by event 1H for cell 1 in timeslot 4. The measurement reporting delay from the beginning of T3 shall be less than 480 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 11) After 5 seconds from the beginning of T4, the SS shall switch the power settings from T4 to T5. 12) UE shall transmit a MEASUREMENT REPORT message triggered by event 1I for cell 2 in timeslot 4. The measurement reporting delay from the beginning of T3 shall be less than 480 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 13) After 5 seconds from the beginning of T5, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 14) Repeat steps 1-13 [TBD] times. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Timeslot ISCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 2 -Intra-frequency event identity Event 1H -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency -68 -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present -Intra-frequency event identity Event 1H -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency -73 -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present -Intra-frequency event identity Event 1I -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency -67 -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 4 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1I -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 4 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1H -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 MEASUREMENT REPORT message (step 10) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 4 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1H -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 MEASUREMENT REPORT message (step 12) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 1 -Timeslot ISCP Checked that this IE is present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1I -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 2
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.4.2 1,28 Mcps TDD Option
Test environment : normal; see clauses G.2.1 and G.2.2. Frequencies to be tested : mid range ;see clauses G.2.4. The test parameters are given in Table 8.6.1.2.4.2A, Table 8.6.1.2.4.2B and Table 8.6.1.2.4.2C below. The test consists of four successive time periods, with a time duration of T1, T2, T3 and T4 respectively. Two cells shall be present in the test, cell 1 being the current serving cell and cell 2 being a neighbour cell on the used frequency. In the measurement control information it shall be indicated to the UE that event-triggered reporting with event 1H and event 1I shall be used and that Timeslot ISCP and P-CCPCH RSCP shall be reported together with event 1H and 1I. Measurement control information shall be sent to the UE before the beginning of time period T1. The UL DPCH shall be transmitted in timeslot 2. In addition, timeslots 5 and 6 shall be allocated as DL timeslots. Table 8.6.1.2.4.2A: General test parameters for correct event 1H and 1I reporting in AWGN propagation condition 1,28Mcps option Parameter Unit Value Comment DCH parameters active cell DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A. Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 Neighbour cell Cell 2 Final condition Active cell Cell 1 O dB 0 Cell individual offset. This value shall be used for all cells in the test. Timeslot list cell 1 5, 6 Timeslot numbers in IE "Cell info" for Cell 1 Timeslot list cell 2 6 Timeslot numbers in IE "Cell info" for Cell 2 Threshold used frequency dBm -68 Applicable for event 1H, cell 1 timeslots 5, 6 and cell 2 timeslot 6 Threshold used frequency dBm -66 Applicable for event 1I, cell 1 timeslots 5, 6 and cell 2 timeslot 6 Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 Cell 2 shall belong to the monitored set T1 s 5 T2 s 5 T3 s 5 T4 s 5 Table 8.6.1.2.4.2B: Cell 1 specific test parameters for correct event 1H and 1I reporting in AWGN propagation condition 1,28Mcps Option Parameter Unit Cell 1 T1 T2 T3 T4 T1 T2 T3 T4 T1 T2 T3 T4 UTRA RF Channel Number Channel 1 DL timeslot number 0 5 6 PCCPCH_Ec/Ior dB -3 DPCH_Ec/Ior dB Note 1 OCNS_Ec/Ior dB -3 Note 2 0 dB 4 3 4 20 4 PCCPCH RSCP dBm -79 n.a. n.a. ISCP dBm Note 3 Note 3 -60 -60 -74.54 -74.54 dBm / 1,28 MHz -80 Note 1: The DPCH level is controlled by the power control loop Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior Note 3: ISCP of TS0 and TS5 remains changeless. Table 8.6.1.2.4.2C: Cell 2 specific test parameters for correct event 1H and 1I reporting in AWGN propagation condition 1,28Mcps option Parameter Unit Cell 2 T1 T2 T3 T4 T1 T2 T3 T4 UTRA RF Channel Number Channel 1 DL timeslot number 0 6 PCCPCH_Ec/Ior dB -3 DPCH_Ec/Ior dB OCNS_Ec/Ior dB -3 0 dB 4 20 4 PCCPCH RSCP dBm -79 n.a. ISCP dBm Note1 -74.54 -60 -60 -74.54 dBm / 1,28 MHz -80 Note1: ISCP of TS0 remains changeless Procedure 1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 5 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 1I for cell 2 in timeslot 6. The measurement reporting delay from the beginning of T2 shall be less than 480 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 5 seconds from the beginning of T2, the SS shall switch the power settings from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 1H for cell 1 in timeslot 6 . The measurement reporting delay from the beginning of T3 shall be less than 480 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 9) After 5 seconds from the beginning of T3, the SS shall switch the power settings from T3 to T4. 10) UE shall transmit a MEASUREMENT REPORT message triggered by event 1H for cell 2 in timeslot 6. The measurement reporting delay from the beginning of T3 shall be less than 480 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 11) After 5 seconds from the beginning of T4, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 12) Repeat steps 1-13 [TBD] times. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3], with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Timeslot ISCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 2 -Intra-frequency event identity Event 1H -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency -68 -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present -Intra-frequency event identity Event 1I -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency -66 -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting MEASUREMENT REPORT message (step 6) MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 6 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1I -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 2 MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 6 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1H -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 MEASUREMENT REPORT message (step 10) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 6 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1H -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 2
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.4.3 7,68 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.4.3.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Tables 8.6.1.2.4.3.1.1, 8.6.1.2.4.3.1.2 and 8.6.1.2.4.3.1.3. The test consists of five successive time periods, with a time duration of T1, T2, T3, T4 and T5 respectively. Two cells shall be present in the test, cell 1 being the current serving cell and cell 2 being a neighbour cell on the used frequency. In the measurement control information it shall be indicated to the UE that event-triggered reporting with event 1H and event 1I shall be used and that Timeslot ISCP and P-CCPCH RSCP shall be reported together with event 1H and 1I. Measurement control information shall be sent to the UE before the beginning of time period T1. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The UL DPCH shall be transmitted in timeslot 10. In addition, timeslots 3 and 4 shall be allocated as DL timeslots. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. Table 8.6.1.2.4.3.1.1: General test parameters for correct event 1H and event 1I reporting in AWGN propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 Neighbour cell Cell 2 Final condition Active cell Cell 1 HCS Not used O dB 0 Cell individual offset. This value shall be used for all cells in the test. Timeslot list cell 1 2, 3, 4 Timeslot numbers in IE "Cell info" for Cell 1 Timeslot list cell 2 4 Timeslot numbers in IE "Cell info" for Cell 2 Threshold used frequency dBm -68 Threshold 1 applicable for event 1H, cell 1 timeslots 2, 4 and cell 2 timeslot 4 Threshold used frequency dBm -73 Threshold 2 applicable for event 1H, cell 1 timeslots 2, 3, 4 and cell 2 timeslot 4 Threshold used frequency dBm -67 Applicable for event 1I, cell 1 timeslots 2, 4 and cell 2 timeslot 4 Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 Cell 2 shall belong to the monitored set T1 s 5 T2 s 5 T3 s 5 T4 s 5 T5 s 5 Table 8.6.1.2.4.3.1.2: Cell 1 specific parameters for correct event 1H and 1I reporting in AWGN propagation condition Parameter Unit Cell 1 T1 T2 T3 T4 T5 T1 T2 T3 T4 T5 UTRA RF Channel Number Channel 1 DL timeslot number 0 2 PCCPCH_Ec/Ior dB -3 n.a. SCH_Ec/Ior dB -9 n.a. SCH_toffset dB 5 n.a. DPCH_Ec/Ior dB n.a. Note 1 OCNS_Ec/Ior dB -3,12 Note 2 dB 4 4 PCCPCH RSCP dBm -69 n.a. dBm / 7,68 MHz -70 Propagation Condition AWGN DL timeslot number 3 4 PCCPCH_Ec/Ior dB n.a. n.a. SCH_Ec/Ior dB n.a. n.a. SCH_toffset dB n.a. n.a. DPCH_Ec/Ior dB n.a. n.a. OCNS_Ec/Ior dB 0 0 dB 3 0 6 PCCPCH RSCP dBm n.a. n.a. dBm / 7,68 MHz -70 Propagation Condition AWGN Note 1: The DPCH level is controlled by the power control loop Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior Table 8.6.1.2.4.3.1.3: Cell 2 specific parameters for correct event 1H and 1I reporting in AWGN propagation condition Parameter Unit Cell 2 T1 T2 T3 T4 T5 T1 T2 T3 T4 T5 UTRA RF Channel Number Channel 1 DL timeslot number 0 2 PCCPCH_Ec/Ior dB -3 n.a. SCH_Ec/Ior dB -9 n.a. SCH_toffset dB 10 n.a. DPCH_Ec/Ior dB n.a. n.a. OCNS_Ec/Ior dB -3,12 0 dB 1 0 6 0 PCCPCH RSCP dBm -72 n.a. dBm / 7,68 MHz -70 Propagation Condition AWGN DL timeslot number 3 4 PCCPCH_Ec/Ior dB n.a. n.a. SCH_Ec/Ior dB n.a. n.a. SCH_toffset dB n.a. n.a. DPCH_Ec/Ior dB n.a. n.a. OCNS_Ec/Ior dB 0 0 dB 3 6 0 PCCPCH RSCP dBm n.a. n.a. dBm / 7,68 MHz -70 Propagation Condition AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.4.3.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 5 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 1I for cell 1 in timeslot 2. The measurement reporting delay from the beginning of T2 shall be less than 480 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 5 seconds from the beginning of T2, the SS shall switch the power settings from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 1H for cell 1 in timeslot 2. The measurement reporting delay from the beginning of T3 shall be less than 480 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 9) After 5 seconds from the beginning of T3, the SS shall switch the power settings from T3 to T4. 10) UE shall transmit a MEASUREMENT REPORT message triggered by event 1H for cell 1 in timeslot 4. The measurement reporting delay from the beginning of T3 shall be less than 480 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 11) After 5 seconds from the beginning of T4, the SS shall switch the power settings from T4 to T5. 12) UE shall transmit a MEASUREMENT REPORT message triggered by event 1I for cell 2 in timeslot 4. The measurement reporting delay from the beginning of T3 shall be less than 480 ms. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 13) After 5 seconds from the beginning of T5, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 14) Repeat steps 1-13 until the confidence level according to annex F.6.2 is achieved. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Timeslot ISCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 2 -Intra-frequency event identity Event 1H -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency -68 -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present -Intra-frequency event identity Event 1H -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency -73 -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present -Intra-frequency event identity Event 1I -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency -67 -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 4 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1I -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case Not Present -Cell parameters ID Set to Cell parameters ID of Cell 1 -SCTD indicator FALSE MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 4 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1H -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case Not Present -Cell parameters ID Set to Cell parameters ID of Cell 1 -SCTD indicator FALSE MEASUREMENT REPORT message (step 10) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 1 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 4 -Timeslot ISCP Checked that this IE is present for 4 timeslots Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1H -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case Not Present -Cell parameters ID Set to Cell parameters ID of Cell 1 -SCTD indicator FALSE MEASUREMENT REPORT message (step 12) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Intra-frequency Measured results list -Intra-frequency measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to Cell parameters ID of cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list 1 -Timeslot ISCP Checked that this IE is present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Intra-frequency measurement event results -Intra-frequency event identity 1I -Cell measurement event results (10.3.7.4) -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case Not Present -Cell parameters ID Set to Cell parameters ID of Cell 2 -SCTD indicator FALSE
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.5 Test requirements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.5.1 3,84 Mcps TDD Option
The UE shall send one event 1I triggered measurement report, with a measurement reporting delay less than 480 ms from the beginning of time period T2. The UE shall send one event 1H triggered measurement report, with a measurement reporting delay less than 480 ms from the beginning of time period T3. The UE shall send one event 1H triggered measurement report, with a measurement reporting delay less than 480 ms from the beginning of time period T4. The UE shall send one event 1I triggered measurement report, with a measurement reporting delay less than 480 ms from the beginning of time period T5. The UE shall not send event 1H or 1I triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of [FFS]% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.5.2 1,28 Mcps TDD Option
The UE shall not send event 1H or 1I triggered measurement reports, as long as the reporting criteria are not fulfilled. The rate of correct events observed during repeated tests shall be at least 90%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.2.5.3 7,68 Mcps TDD Option
The UE shall send one event 1I triggered measurement report, with a measurement reporting delay less than 480 ms from the beginning of time period T2. The UE shall send one event 1H triggered measurement report, with a measurement reporting delay less than 480 ms from the beginning of time period T3. The UE shall send one event 1H triggered measurement report, with a measurement reporting delay less than 480 ms from the beginning of time period T4. The UE shall send one event 1I triggered measurement report, with a measurement reporting delay less than 480 ms from the beginning of time period T5. The UE shall not send event 1H or 1I triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of 95% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3 Correct reporting of neighbours in fading propagation conditions
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.1 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.1.1 Definition and applicability
In the event triggered reporting, the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (3,84 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.1.2 Minimum requirement
The requirements are the same as in sub clause 8.6.1.1.2 The normative reference for this requirement is TS 25.123 [2] clauses 8.1.2.2.2.1, 8.1.2.2.2 and A.8.1.3
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.1.3 Test purpose
To verify that the UE meets the minimum requirements and also verify that the UE performs sufficient layer 1 filtering of the measurements. The test is performed in fading propagation conditions.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.1.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Tables 8.6.1.3.1 and 8.6.1.3.2. The test consists of one time period with time duration of T1. Two cells shall be present in the test, cell 1 being the current serving cell and cell 2 being a neighbour cell on the used frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 1G shall be used, and that P-CCPCH RSCP shall be reported together with Event 1G. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The TTI of the UL DCCH shall be 20ms. Table 8.6.1.3.1: General test parameters for correct reporting of neighbours in fading propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 Neighbour cell Cell 2 Final condition Active cell Cell 1 O dB 0 Cell individual offset. This value shall be used for all cells in the test. Hysteresis dB 0 Time to Trigger ms 200 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 Sent before the beginning of time period T1 T1 s 200 Table 8.6.1.3.2: Cell specific test parameters for correct reporting of neighbours in fading propagation condition Parameter Unit Cell 1 Cell 2 T1 T1 T1 T1 DL timeslot number 0 8 0 8 UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 n.a. -3 n.a. SCH_Ec/Ior dB -9 -9 -9 -9 SCH_toffset 0 0 2 2 PICH_Ec/Ior dB n.a. -3 n.a. -3 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 -3,12 dB 7 7 2 2 PCCPCH RSCP dBm -66 n.a. -71 n.a. dBm/ 3,84 MHz -70 Propagation Condition Case 4 as specified in Annex DTS25.102 Annex B
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.1.4.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 200 seconds from the beginning of T1, the UE is switched off. 6) Repeat steps 1-5 [TBD] times. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 1 -Intra-frequency event identity Event 1G -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency Not Present -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.1.5 Test requirements
The number of Event 1G triggered measurement reports during time period T1 shall be less than 60. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of [FFS]% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.2 1,28 Mcps TDD Option
Void.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3 7,68 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.1 Definition and applicability
In the event triggered reporting, the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (7,68 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.2 Minimum requirement
The requirements are the same as in sub clause 8.6.1.1.2 The normative reference for this requirement is TS 25.123 [2] clauses , 8.1B.2.2.2 and A.8.1.3.3
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.3 Test purpose
To verify that the UE meets the minimum requirements and also verify that the UE performs sufficient layer 1 filtering of the measurements. The test is performed in fading propagation conditions.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Tables 8.6.1.3.3.4.1.1 and 8.6.1.3.3.4.1.2. The test consists of one time period with time duration of T1. Two cells shall be present in the test, cell 1 being the current serving cell and cell 2 being a neighbour cell on the used frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 1G shall be used, and that P-CCPCH RSCP shall be reported together with Event 1G. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The TTI of the UL DCCH shall be 20ms. Table 8.6.1.3.3.4.1.1: General test parameters for correct reporting of neighbours in fading propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 Neighbour cell Cell 2 Final condition Active cell Cell 1 O dB 0 Cell individual offset. This value shall be used for all cells in the test. Hysteresis dB 0 Time to Trigger ms 200 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 Sent before the beginning of time period T1 T1 s 200 Table 8.6.1.3.3.4.1.2: Cell specific test parameters for correct reporting of neighbours in fading propagation condition Parameter Unit Cell 1 Cell 2 T1 T1 T1 T1 DL timeslot number 0 8 0 8 UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 n.a. -3 n.a. SCH_Ec/Ior dB -9 -9 -9 -9 SCH_toffset 0 0 2 2 PICH_Ec/Ior dB n.a. -3 n.a. -3 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 -3,12 dB 7 7 2 2 PCCPCH RSCP dBm -66 n.a. -71 n.a. dBm/ 7,68 MHz -70 Propagation Condition Case 4 as specified in TS25.102 Annex B
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.4.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 200 seconds from the beginning of T1, the UE is switched off. 6) Repeat steps 1-5 until the confidence level according to annex F.6.2 is achieved.. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 1 -Intra-frequency event identity Event 1G -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency Not Present -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.5 Test requirements
The number of Event 1G triggered measurement reports during time period T1 shall be less than 60. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of 95% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2 TDD inter frequency measurements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1 Correct reporting of neighbours in AWGN propagation condition
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.1 Definition and applicability
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.1.1 3,84 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (3,84 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.1.2 1,28 Mcps TDD Option
The purpose of this test is to verify that the UE makes correct reporting of an event within the required times when doing inter frequency measurements on a neighbouring TDD cell. The test will partly verify the requirements in section 8.1A.2 and 9.1. of [2]. The requirements and this test apply to the TDD (1.28 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.1.3 7,68 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (7,68 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.2 Minimum requirement
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.2.1 3,84 Mcps TDD Option
When idle intervals are used for inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within If the UE does not require idle intervals to perform inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within 5000 ms. When idle intervals are used for TDD inter frequency measurements, the UE shall be capable of performing P-CCPCH RSCP measurements for Xmeasurement TDD inter inter-frequency TDD cells per TDD frequency of the monitored set. The UE physical layer shall be capable of reporting measurements to higher layers with measurement accuracy as specified in section 9 and with a measurement period of Tmeasurement inter. If the UE does not require idle intervals to perform TDD inter-frequency measurements, the measurement period for inter frequency P-CCPCH RSCP measurements shall be 480 ms. Where, Xmeasurement TDD inter = 6 (cells) Tmeasurement_period inter = 480 ms. The time period used for calculating the measurement period Tmeasurement_inter for inter frequency P-CCPCH RSCP measurements. NTDD inter: This is the available number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period TTDD inter. The UE shall consider that a measurement opportunity on a Beacon timeslot of an inter-frequency TDD cell is provided if an idle interval of length equal to or greater than 3 timeslots less 2*0.5 ms implementation margin for frequency switching per idle interval completely overlaps in time with the Beacon timeslot of the inter-frequency TDD cell. Nbasic_identify_TDD inter = 80. This is a number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period used in the inter frequency TDD equation where the maximum allowed time for the UE to identify a new detectable inter-frequency TDD cell is defined. Nbasic_measurement_TDD inter = 5. This is a number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period TTDD inter used in the inter-frequency TDD equation where the measurement period for inter-frequency P-CCPCH RSCP measurements is defined. NFreq TDD: This is the number of TDD frequencies indicated in the inter frequency measurement control information. The event triggered measurement reporting delay, measured without L3 filtering shall be less than T identify inter defined in 25.123 [2]. When L3 filtering is used, an additional delay can be expected. The normative reference for this requirement is TS 25.123 [2] clauses 8.1.2.3.1, 8.1.2.3.2 and A.8.2.1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.2.2 1,28 Mcps TDD Option
When idle intervals are used for inter-frequency TDD measurements, the UE shall be able to identify a new detectable cell belonging to the monitored set within when NInter: This is the minimum number of sub-frame in that the signal of P-CCPCH and DwPCH can be received for inter frequency target cell during the period TMeasurement_Period inter with an arbitrarily chosen timing. It depends on the channel allocation and is calculated by assuming 2*0.1ms for implementation margin (for the description of the idle intervals see Annex A of 25.225). Tbasic_identify_TDD,inter= 800ms. This is the time period used in the inter frequency equation where the maximum allowed time for the UE to identify a new TDD cell is defined. TMeasurement_Period Inter= 480 ms. The period used for calculating the measurement period Tmeasurement_inter for inter frequency P-CCPCH RSCP measurements. NFreq: Number of TDD frequencies indicated in the inter frequency measurement control information. If the UE does not require idle intervals to perform inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within 5000 ms. A cell shall be considered detectable when P-CCPCH Ec/Io > -8 dB and DwPCH_Ec/Io > -5 dB. When L3 filtering is used an additional delay can be expected. The test consist of 2 successive time periods, with a time duration T1 and T2. The test parameters are given in tables A.8.2C and A.8.2D below. Two cells shall be present in the test, cell 1 being the active cell and cell 2 being a 1.28Mcps TDD option neighbour cell on the unused frequency. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used. P-CCPCH RSCP of the best cell on the unused frequency shall be reported together with Event 2C reporting. The measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in 25.331 [9]
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.2.3 7,68 Mcps TDD Option
When idle intervals are used for inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within If the UE does not require idle intervals to perform inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within 5000 ms. When idle intervals are used for TDD inter frequency measurements, the UE shall be capable of performing P-CCPCH RSCP measurements for Xmeasurement TDD inter inter-frequency TDD cells per TDD frequency of the monitored set. The UE physical layer shall be capable of reporting measurements to higher layers with measurement accuracy as specified in section 9 and with a measurement period of Tmeasurement inter. If the UE does not require idle intervals to perform TDD inter-frequency measurements, the measurement period for inter frequency P-CCPCH RSCP measurements shall be 480 ms. Where, Xmeasurement TDD inter = 6 (cells) Tmeasurement_period inter = 480 ms. The time period used for calculating the measurement period Tmeasurement_inter for inter frequency P-CCPCH RSCP measurements. NTDD inter: This is the available number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period TTDD inter. The UE shall consider that a measurement opportunity on a Beacon timeslot of an inter-frequency TDD cell is provided if an idle interval of length equal to or greater than 3 timeslots less 2*0.5 ms implementation margin for frequency switching per idle interval completely overlaps in time with the Beacon timeslot of the inter-frequency TDD cell. Nbasic_identify_TDD inter = 80. This is a number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period used in the inter frequency TDD equation where the maximum allowed time for the UE to identify a new detectable inter-frequency TDD cell is defined. Nbasic_measurement_TDD inter = 5. This is a number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period TTDD inter used in the inter-frequency TDD equation where the measurement period for inter-frequency P-CCPCH RSCP measurements is defined. NFreq TDD: This is the number of TDD frequencies indicated in the inter frequency measurement control information. The event triggered measurement reporting delay, measured without L3 filtering shall be less than T identify inter defined in 25.123 [2]. When L3 filtering is used, an additional delay can be expected. The normative reference for this requirement is TS 25.123 [2] clauses 8.1B.2.3.1, 8.1B.2.3.2 and A.8.2.1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.3 Test purpose
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.3.1 3,84 Mcps TDD Option
To verify that the UE meets the minimum requirement.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.3.2 1,28 Mcps TDD Option
To verify that the UE meets the minimum time requirements for identifying neighbouring TDD cells
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.3.3 7,68 Mcps TDD Option
To verify that the UE meets the minimum time requirements for identifying neighbouring interfrequency TDD cells.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.1 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.1.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Table 8.6.2.1.1 and 8.6.2.1.2. The test consists of 2 successive time periods, with a time duration T1 and T2. Two cells shall be present in the test, cell 1 being the serving cell and cell 2 being a UTRA TDD neighbour cell on the unused frequency. All cells shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used. P-CCPCH RSCP of the best cell on the unused frequency shall be reported together with Event 2C reporting. The Measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in [9]. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The DL DPCH shall be transmitted in timeslot 1 and the UL DPCH shall be transmitted in timeslot 3. The TTI of the uplink DCCH shall be 20 ms. Table 8.6.2.1.1: General test parameters for Correct reporting of TDD inter-frequency neighbours in AWGN propagation condition (3,84 Mcps option) Parameter Unit Value Comment DPCH parameters DL Reference Measurement Channel 12.2 kbps As specified in Annex CTS 25.102 annex A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 UTRA TDD cell Neighbour cell Cell 2 UTRA TDD cell Threshold non used frequency dB -71 Applicable for event 2C Hysteresis dB 0 Applicable for event 2C Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 24 on channel 1 16 on channel 2 T1 s 10 T2 s 10 Table 8.6.2.1.2: Cell specific parameters for Correct reporting of TDD inter-frequency neighbours in AWGN propagation condition (3,84 Mcps option) Parameter Unit Cell 1 Cell 2 Timeslot Number 0 8 0 8 T1 T2 T1 T2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 -9 -9 -9 -9 -9 SCH_toffset 0 0 0 0 15 15 15 15 PICH_Ec/Ior -3 -3 -3 -3 OCNS -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 dB 3 3 3 3 -Infinity 9 -Infinity 9 dBm/3,84 MHz -70 PCCPCH_RSCP dB -70 -70 -Infinity -64 Propagation Condition AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.1.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 10 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 2c for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5080 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 10 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 8) Repeat steps 1-7 [TBD] times. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: NOTE: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail.MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info (10.3.6.36) -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Cell info (10.3.7.2) -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 3,84 Mcps TDD -CHOICE Sync case 2 -Timeslot 0 -cell parameters ID Set to cell parameters ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.6.2.1.2 -Timesllot list Not Present -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) Not Present -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria (10.3.7.19) -Parameters required for each event 1 -Intra-frequency event identity Event 2C -Threshold used frequency Not Present -W Used frequency Not Present -Hysteresis 0 dB -Time to trigger 0 ms -Reporting Cell Status (10.3..61) -CHOICE reported cell Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency -Maximum number of reported cells 3 -Parameters required for each non-used frequenc - Threshold non-used frequency -71 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -CHOICE mode TDD -Primary CCPCH Info -CHOICE mode TDD -CHOICE TDD Option 3,84 Mcps TDD -CHOICE Sync Case Not Present -Cell Parameters ID Set to cell parameters ID of Cell 2 -SCTD Indicator FALSE
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.2 1,28 Mcps TDD Option
Test environment : normal; see clauses G.2.1 and G.2.2. Frequencies to be tested : mid range ;see clauses G.2.4. Cell 1 is the active cell, Cell 2 is a neighbour cell on the unused frequency. The power level on Cell 1 is kept constant and the power level of Cell 2 is changed using "change of best cell event". General test parameters are given in the table 8.6.2.1.3 below and they are signalled from test device. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used. P-CCPCH RSCP of the best cell has to be reported together with Event 2C reporting. New measurement control information, which defines neighbour cells etc., is always sent before the event starts. The cell specific test parameters are shown in Table 8.6.2.1.4. Table 8.6.2.1.3: General test parameters for correct reporting of TDD inter frequency neighbours in AWGN propagation condition 1,28Mcps option Parameter Unit Value Comment DPCH parameters active cell DL and UL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2. The DPCH is located in an other timeslot than 0 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 1.28Mcps TDD cell Neighbour cell Cell 2 1.28Mcps TDD cell Final condtions Active cell Cell 1 Threshold non used frequency dBm -71 Absolute P-CCPCH RSCP threshold for event 2C W non-used frequency 1 Applicable for event 2C Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 24 on channel 1 16 on channel 2 Measurement control information is sent before T1 starts. T1 s 10 T2 s 10 Table 8.6.2.1.4 Cell Specific Parameters for Correct Reporting of Neighbours in AWGN Propagation Condition 1,28Mcps option Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS T1 T2 T1 T2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 3 3 -Infinity 8 dBm/1.28 MHz -70 PCCPCH_RSCP dBm -70 -70 -Infinity -65 Propagation Condition AWGN NOTE: The DPCH of all cells are located in a timeslot other than 0. 8.6.2.1.4.2.2 Test Procedure 1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 10 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 2c for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5080 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 10 seconds from the beginning of T2, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 8) Repeat steps 1-7 until the confidence level according to annex F.6.2 is achieved. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex A of 34.123-1 [21], with the following exceptions: Note: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail. MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info (10.3.6.36) -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Cell info (10.3.7.2) -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps TDD -cell parameters ID Set to cell parameters ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.6.2.1.2 -Timesllot list Not Present -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI FALSE -Frequency quality estimate FALSE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) Not Present -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria (10.3.7.19) -Parameters required for each event 1 -Intra-frequency event identity Event 2C -Threshold used frequency Not Present -W Used frequency Not Present -Hysteresis 0 dB -Time to trigger 0 ms -Reporting Cell Status (10.3..61) -CHOICE reported cell Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency -Maximum number of reported cells 3 -Parameters required for each non-used frequenc - Threshold non-used frequency -71 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Non frequency related measurement event results -CHOICE mode TDD -Primary CCPCH Info -CHOICE mode TDD -CHOICE TDD Option 1.28 Mcps TDD -TSTD indicator TRUE -Cell Parameters ID Set to cell parameters ID of Cell 2 -SCTD Indicator FALSE