Datasets:
Tasks:
Tabular Regression
Formats:
csv
Languages:
English
Size:
1K - 10K
Tags:
roller-compaction
pharmaceutical-manufacturing
dry-granulation
scale-up
quality-by-design
twin-feed-screw
License:
File size: 4,835 Bytes
2db5f00 aa594dc | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 | ---
license: cc-by-4.0
language:
- en
pretty_name: "IPA Pharmaceutical Roller Compactor Platform: Scale-Up & Performance (Synthetic)"
size_categories:
- 1K<n<10K
task_categories:
- tabular-regression
tags:
- roller-compaction
- pharmaceutical-manufacturing
- dry-granulation
- scale-up
- quality-by-design
- twin-feed-screw
- process-engineering
- synthetic-data
- education
configs:
- config_name: default
data_files:
- split: train
path: "ipa_pharma_compactor_v1.0.csv"
---
# IPA Pharmaceutical Roller Compactor Platform: Scale-Up & Performance (Synthetic)
**Version:** 1.0
**Publisher:** [Innovative Process Applications (IPA)](https://www.innovativeprocess.com)
**License:** Creative Commons Attribution 4.0 International (CC BY 4.0)
> ⚠️ **This dataset is 100% synthetic and intended for educational use only.**
> Generated from IPA's published CL-series specifications and standard
> compaction physics — not real production or clinical batch data.
---
## What's in this dataset
3,000 simulated pharmaceutical roller compaction runs spanning IPA's complete
CL-series platform — from R&D lab (CL25150, 5 HP) through full production
(CL100250, 25 HP) — across 5 pharma/nutraceutical materials and the full
operating envelope of twin-feed-screw process parameters.
### Equipment specifications (from IPA published data)
| Model | Roll Size | Max Pressure | Integrated Mill | Power | Scale |
|---|---|---|---|---|---|
| CL25150 | 1"×6" (2.5×15 cm) | 17.5 kN/cm | None | 5 HP | R&D / Lab |
| CL30200 | 1"×8" (3×20 cm) | 17.5 kN/cm | PM3 | 2.75 HP | Pilot |
| CL50200 | 2"×8" (5×20 cm) | 26.0 kN/cm | PM6 | 12 HP | Pilot / Small Prod |
| CL75200 | 3"×8" (7.5×20 cm) | 15.0 kN/cm | PM6 | 20 HP | Production |
| CL100250 | 4"×10" (10×25 cm) | 17.5 kN/cm | PM8 | 25 HP | Full Production |
### Column descriptions
| Column | Units | Description |
|---|---|---|
| `compactor_model` | — | IPA CL-series model |
| `scale` | — | R&D / Lab, Pilot, Production, Full Production |
| `roll_diameter_in` / `_cm` | in / cm | Roll diameter |
| `roll_width_in` / `_cm` | in / cm | Roll width |
| `max_roll_pressure_kn_cm` | kN/cm | Maximum specific compaction force |
| `integrated_mill` | — | PM-series in-air impact mill (or None) |
| `total_power_kw` | kW | Total system power |
| `material` | — | Pharma material identifier |
| `feed_density_gcc` | g/cc | Feed powder bulk density |
| `deformation_type` | — | Plastic, brittle, or mixed |
| `roll_pressure_fraction` | — | Fraction of max pressure applied (0.3–1.0) |
| `scf_kn_cm` | kN/cm | Actual specific compaction force |
| `roll_speed_rpm` | rpm | Roll rotation speed |
| `hfs_speed_rpm` | rpm | Horizontal feed screw speed (controls throughput) |
| `vfs_hfs_ratio` | — | Vertical/horizontal feed screw speed ratio (controls pre-compression) |
| `gap_width_mm` | mm | Roll gap |
| `ribbon_rel_density` | — | Relative density (fraction of true density) |
| `ribbon_density_gcc` | g/cc | Absolute ribbon density |
| `ribbon_porosity` | — | 1 − relative density |
| `density_cv_pct` | % | Across-ribbon density uniformity |
| `fines_pct` | % | Fines fraction after milling |
| `granule_yield_pct` | % | Usable granule yield |
| `in_zinchuk_window` | Yes/No | Ribbon RD in 0.60–0.80 tabletability range |
| `throughput_kg_hr` / `_lbs_hr` | kg/hr / lbs/hr | Mass throughput |
| `specific_energy_kwh_tonne` | kWh/tonne | Energy efficiency |
| `changeover_time_hr` | hours | Estimated changeover time |
## IPA platform advantages demonstrated in the data
1. **Twin feed screw (HFS + VFS):** Independent control of throughput (HFS)
and pre-compression (VFS) produces a uniquely tunable operating space.
The VFS/HFS ratio is a key process parameter not available on single-screw
compactors.
2. **Scalable platform:** Consistent ribbon quality (CV%, yield) across the
CL25150 → CL100250 range, enabling direct R&D-to-production scale-up.
3. **Integrated in-air impact milling:** PM-series mills minimize heat
generation and maximize granule yield with precise PSD control.
4. **Efficient changeover:** Modular design enables fast product changeover,
critical for multi-product pharma facilities.
5. **Low bulk density capability:** Twin screw design is proven efficient
with light powders (feed density 0.3–0.5 g/cc) containing high air content.
## Cross-links
- **Kaggle:** [link after publication]
- **Hugging Face:** [link after publication]
- **Zenodo:** [link after publication]
- **GitHub:** [link after publication]
- **IPA website:** https://www.innovativeprocess.com
## Citation
> Innovative Process Applications (2026). *IPA Pharmaceutical Roller Compactor
> Platform: Scale-Up & Performance (Synthetic), v1.0*. CC BY 4.0.
> https://www.innovativeprocess.com
|