File size: 18,961 Bytes
5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb ff59ad3 5e2d1eb bc4e333 5e2d1eb 2843cff bc4e333 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 65f33bb 5e2d1eb bc4e333 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb bc4e333 2843cff 5e2d1eb 2843cff bc4e333 2843cff bc4e333 5e2d1eb 2843cff 5e2d1eb b224bd3 2843cff b224bd3 2843cff b224bd3 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 2843cff 5e2d1eb 94e56dd 5e2d1eb 2843cff 5e2d1eb bc4e333 5e2d1eb 2843cff 5e2d1eb bc4e333 5e2d1eb | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 | ---
license: apache-2.0
language:
- en
library_name: custom
pipeline_tag: image-to-text
tags:
- ocr
- document-ai
- information-extraction
- key-information-extraction
- nameplate
- nameplate-ocr
- equipment-nameplate
- data-center
- data-centre
- datacenter
- mission-critical
- mep
- electrical
- mechanical
- equipment-schedule
- schedule-verification
- asset-register
- commissioning
- quality-assurance
- ups
- pdu
- switchgear
- generator
- ats
- transformer
- busway
- battery
- crah
- crac
- chiller
- cooling
- server-rack
- construction
- aec
- edge-ai
- on-device
- privacy-preserving
- tesseract
- browser
metrics:
- accuracy
- f1
model-index:
- name: data-centre-nameplates
results:
- task:
type: image-to-text
name: Equipment-nameplate field extraction & schedule verification
dataset:
name: Data Centre Construction labelled plate corpus (n = 1000)
type: constructelligence/nameplate-corpus
split: clean
metrics:
- type: accuracy
value: 0.941
name: Exact-plate accuracy (clean)
- type: f1
value: 0.997
name: Micro-F1 (clean)
- type: f1
value: 0.799
name: Micro-F1 (character-error stress)
---
# Data Centre Construction — equipment-nameplate OCR checked against the equipment schedule
> **Constructelligence is developing frontier construction-AI models.** This kit is the *lite*, open tier —
> released for research and evaluation; the company's flagship production models are a separate, larger
> tier (see [constructelligence.co](https://constructelligence.co)).
**Read an equipment nameplate and know if it is the unit the schedule asked for.** Point a phone at the
nameplate of a UPS, PDU, switchgear, generator, transformer, busway, battery, CRAH, chiller — or a **server
rack** — and the engine returns the plate's fields (35 of them, grouped Identification / Electrical / Cooling /
Server racks / Mechanical) and **checks each one against the equipment schedule**, flagging a mismatch instead
of a silent pass. It builds an asset register and exports it to CSV.
Built for the part of a data-centre job where the gear *is* the job. The expensive mistakes are a unit
delivered at the wrong voltage or rating, or one that quietly never makes it onto the asset register.
> **Runs on the device.** OCR, extraction and matching run in the browser (or Node) with no server and no
> upload. A nameplate photo of live infrastructure never leaves the phone that took it — no GPU, no key, no
> data egress.
**▶ Try it live:** [huggingface.co/spaces/constructelligence/data-centre-nameplates](https://huggingface.co/spaces/constructelligence/data-centre-nameplates) — a browser demo with a sample schedule and sample plates.
| | |
|---|---|
| **Task** | Image → structured nameplate fields → schedule verification |
| **Fields** | **35**, in five groups (Identification, Electrical, Cooling, Server racks/IT, Mechanical) |
| **Equipment** | **55 types**, device wording ranked above family (see below) |
| **OCR** | Tesseract.js 5 (English LSTM), pretrained — no fine-tuning |
| **Extraction** | Deterministic labelled-field parser + OCR error model + numeric range guards |
| **Matching** | Code folding (`O/0`, `I/L/1`, `S/5`, `B/8`, `Z/2`) + voltage-compatibility signal |
| **Quality gate** | Advisory photo check (blur, glare, darkness, resolution) before OCR |
| **Runtime** | Browser · Node · edge — no GPU, no server, no data egress |
| **Field accuracy** | **99.8%** clean / **80.0%** under character-error stress (extraction benchmark) |
| **Licence** | Apache-2.0 |
---
## Why this exists
General OCR reads the text on a nameplate. A commissioning or QA team needs the text to answer a narrower
question: **is this the right unit, and does it match what was specified?** That means three things a plain
OCR call does not do:
1. **Turn plate text into fields, not paragraphs.** "INPUT: 480Y/277 VAC 3 PH 60 HZ" becomes
`voltage=480Y/277 V`, `phase=3`, `hz=60`; "RATING: 750 KVA / 675 KW" becomes `kva=750`, `kw=675`.
2. **Survive the way OCR misreads plate lettering.** Serifed `V`→`Vv`, `K`→`X` (`XVA`), `HZ`→`Hw`, codes split
after their punctuation (`NPX- 750- 480`). The parser repairs these before matching, and rejects
out-of-range noise (`0 KVA`, a stray `0` amp) rather than recording it.
3. **Compare to the schedule the way codes actually differ.** Model and serial codes are compared with
`O/0`, `I/L/1`, `S/5`, `B/8`, `Z/2` folded and punctuation ignored, so a misread is not a false mismatch,
while a genuine voltage variant (`NPX-750-415` vs `NPX-750-480`) still fails. A voltage a plate and a
schedule row share is a positive signal; the equipment **type** still wins ties, so a 415 V UPS plate is not
matched to a same-voltage PDU.
The result is a pass/mismatch verdict per plate, with the fields that disagree named.
## How it works
```
photo ─► photo check ─► OCR (Tesseract.js) ─► field parser ─► equipment typing ─► schedule matcher ─► verdict + CSV
blur/glare lines + confidence labelled rules maker line excluded code folding, voltage signal
```
1. **Photo check** — an advisory blur/glare/darkness/resolution read before OCR; the shot can be retaken
before a bad read.
2. **OCR** (`tesseract.js@5`, English) returns lines with a per-line confidence; two page-segmentation passes
are merged field by field when the first is weak.
3. **Field parser** scans lines for labelled values (`MODEL`, `S/N`, `MVA`, `MCA`, `MOCP`, `FLA`, `VOLTS`,
`REFRIGERANT`, `MFG DATE`, …), reading voltages as `480Y/277`, `13.8 kV`, `208/120`, and rejecting
look-alikes. Numeric fields are range-guarded. Lines OCR scored near zero are dropped first.
4. **Equipment typing** recognises **55 families** and ranks the specific device above its family (flywheel
before UPS; paralleling gear before generator; dry cooler before chiller; rack before server). The **maker
line is excluded** from typing, so a vendor called “…Transformer Corp” cannot type a chiller plate.
5. **Schedule matcher** ranks candidate tags — a serial match wins outright; otherwise model similarity
dominates, with manufacturer, equipment type and a compatible voltage as signals. Among equal matches the
first **unscanned** tag is offered.
6. **Field checks** compare the reading to the chosen row (`ok` / `mismatch` / `unread` per field) and return
an overall status: `verified`, `partial`, `mismatch`, `unmatched` or `missing` (scheduled but not scanned).
## Fields extracted (35)
**Identification** — `manufacturer`, `model`, `serial`, `mfgDate`
**Electrical**
| Field | Example | Notes |
|---|---|---|
| `voltage` | 480Y/277 V | every voltage on the plate; `13.8 kV`, `208/120`, `480` |
| `phase` / `hz` | 3 / 60 | `PH`/`PHASE`/`Ø`; 50 or 60 Hz |
| `kva` / `kw` | 750 / 675 | `kVA`, `KW`, `EKW`; thousands separators |
| `amps` | 1002 | labelled `FLA`/`RLA`/`CURRENT`/`AMPS` first |
| `pf` | 0.8 | power factor, 0–1 |
| `mca` / `mocp` | 612 / 800 | min circuit ampacity; max overcurrent protection |
| `sccr` | 65 | short-circuit / interrupting rating (kAIC) |
| `enclosure` | NEMA 3R | NEMA type or IEC IP code |
| `standards` | UL 1989 | UL / IEC / ANSI / IEEE / NFPA / CSA / EN listings |
| `batteryType` | VRLA | VRLA, AGM, Gel, Flooded, Li-ion, LiFePO4, NiCd, Lead-acid |
| `batteryAh` / `cells` | 500 / 48 | amp-hours; cell count |
**Cooling** — `refrigerant`, `charge`, `tons`, `btu`, `cfm`, `gpm`
**Server racks / IT** — `uHeight` (rack U, incl. "42RU"), `formFactor` (blade / tower / a labelled "2U"),
`powerW`, `rackLoad` (static/dynamic load, kg), `outletTypes` (canonical outlet mix, e.g. `C13x12 C19x4`),
`outlets`, `portSpeed` (fastest link, GbE), `ports`
**Mechanical** — `rpm`, `weight` (normalised to kg)
## Equipment types recognised (55)
Power: flywheel · UPS · STS · ATS · rectifier/DC · inverter · BESS · nitrogen generator · paralleling gear ·
generator · fuel system · switchgear/switchboard · MCC · metering/CT · protective relay · transformer/DGA monitor ·
SPD · capacitor/PFC · neutral grounding resistor · VFD · busway · panelboard · PDU/RPP · battery · load bank
Cooling & mechanical: heat pump · pump · cooling tower · thermal storage · chiller · dry cooler/condenser · CDU ·
CRAH/CRAC · AHU · heat exchanger · expansion tank · air separator · boiler · humidifier · water treatment ·
air dryer · compressor · fan coil · rooftop unit · makeup air · economizer
Fire, safety & controls: fire suppression · fire alarm · leak/gas detection · BMS/EPMS/DCIM
IT & white space: **rack** · **server/storage** · network gear · KVM/console
## Server racks — a first-class subsection
Racks, rack PDUs, switches and in-row cooling are what the electrical and cooling design actually serves, so
they are treated as data-centre equipment, not an afterthought: `Rack U`, `Form factor`, `Power (W)`,
`Rack load (kg)`, `Outlet mix`, `PDU outlets`, `Port speed (GbE)` and `Ports` are extracted and checked like any
other field, and the equipment set covers rack/enclosure, server, network, KVM and rack PDU. Sample plates
include a PowerEdge-class server, a rack PDU with a C13/C19 outlet mix, a 25G switch and a blade chassis with a
static floor load.
## Results
### Extraction benchmark — labelled plates, field by field
A generated corpus of plates with **by-construction** ground truth (not the parser's own reading), rendered
with wording variety. `clean` isolates the extractor + matcher; `ocr` adds the character errors OCR makes on
plate lettering. n = 1000. Reproduce with `node tests/nameplates-extraction-bench.mjs --n=1000`.
| Condition | Exact plate | Micro-F1 | ms/plate |
|---|:---:|:---:|---:|
| clean | **94.1%** | **99.7%** | 0.49 |
| ocr (character-error stress) | 1.1% | **79.9%** | 0.49 |
Per-field F1 is 100% for manufacturer, type, model, serial, kVA, phase, Hz, MCA, MOCP, refrigerant,
pf, cfm, uHeight, sccr and enclosure in the clean condition; the residual clean misses are a small number of
voltage and `mfgDate` cases. The `ocr` condition is deliberately harsh (per-character flips); low-confidence
fields are surfaced for a human rather than trusted. Per-field tables: `eval/extraction-bench.json`.
### OCR benchmark — drawn plates through phone-photo degradations
Plates drawn for several equipment types, each pushed through real-photo degradations (small, blurred, noisy,
low-contrast, glare, tilted, keystoned, dark anodised, JPEG, plate-small-in-scene, sideways, and a "phone"
composite), then run through the app's own OCR + parser and scored field by field. An earlier run over six
plate types and 13 conditions scored **99.9% overall (727/728)**; the harness now draws more plate types and
is re-run on release. Run it with `node tests/nameplates-bench.mjs` (needs a browser for Tesseract.js).
**Read this honestly.** These are machine-drawn plates. A real plate on a live unit is harder: cast shadows,
embossed lettering, print over brushed metal, a plate half out of frame. Expect the degradation suite, not the
clean row, and treat every low-confidence field as one a person must confirm.
## Comparison with related models
Nameplate extraction has no shared public benchmark — FUNSD/CORD measure invoices and forms, not equipment
plates. These are the closest published reference points, on **their own** datasets; they are context, not a
head-to-head. The only directly comparable scores are ones produced by the corpus in
`ml/nameplates/bench/`.
| Model / method | Task & dataset | Reported |
|---|---|---|
| **This engine** | **named-field extraction, own labelled plate corpus** | **99.7% micro-F1 (clean)** |
| LayoutLMv3 (base) | entity extraction, FUNSD | 92.08 F1 |
| LiLT | entity extraction, FUNSD | 88.41 F1 |
| Donut | field extraction, CORD | 84.1 F1 |
| CTPN + Transformer | power-equipment nameplate detection / recognition | 88.7% det F1 · 92.3% char acc |
| PP-OCRv4 (TL-DREN) | electricity nameplate detection / recognition | 0.524 det F1 · 0.82 rec acc |
| RNN nameplate OCR | power-equipment nameplate chars (zh + alnum) | 99.9% zh · 99.3% alnum |
| OCR-free VLM (e.g. Qwen2.5-VL-7B) | document KIE, zero-shot | varies; strong but large |
What is different here: the engine is **small, deterministic, on-device, and schedule-aware**. It does not
just transcribe a plate — it decides `verified` / `mismatch` against a schedule and names the fields that
disagree, which no general document model does out of the box.
## Fine-tuning — the higher-accuracy server model
Alongside the on-device path, a **Donut** model
([`naver-clova-ix/donut-base`](https://huggingface.co/naver-clova-ix/donut-base)) is fine-tuned to read a plate
**straight into fields** (`<s_nameplate><s_type>ups</s_type><s_manufacturer>…`) for a server / endpoint where
the browser engine falls short. Training data is synthetic plates with real-photo degradations plus corrected
real plates; best checkpoints are selected by **field accuracy**, using the same OCR-aware comparison the app
uses. The corpus in `ml/nameplates/bench/` scores it on the same test set as the on-device engine.
Nothing on this page claims the accuracy of that model yet — it is the roadmap, not a result.
## Intended use
- **Commissioning and QA walks:** photograph each unit as it is installed; confirm the delivered unit matches
the equipment schedule; capture an asset register as you go.
- **Receiving and delivery checks:** flag the unit that arrived at the wrong voltage or rating before it is set.
- **Register completion:** track scheduled tags that have no plate scanned against them yet.
- **Takeoff and submittal review:** pull model/rating fields off a plate photo into a spreadsheet.
### Out of scope — do not use it for
- **Safety, code compliance or energisation decisions.** It reads a plate; it does not verify that a unit is
safe to energise, correctly protected, or code-compliant.
- **An as-built or a legal record on its own.** OCR misreads happen; low-confidence fields are highlighted and
any field that disagrees with the schedule must be confirmed by eye.
- **Serial-number evidence in a dispute** without human verification; the register flags duplicate serials but
cannot tell a repeated plate from a copied number.
## Limitations
- **English nameplates**, Latin script. Non-Latin or handwritten plates are out of scope.
- **Glare, blur and angle degrade OCR.** The parser repairs common misreads, but a badly glared or very
low-contrast plate will lose fields (those come back `unread`, not invented).
- **Deterministic parser, not a language model.** It reports only what it can match to a rule; it will not
infer a missing digit.
- **The schedule must be structured** (CSV with a Tag or Model column). Free-form schedule PDFs are not parsed
here.
## Quickstart
The engine is plain ES modules with no build step. `nameplate-model.js` is the extractor and verifier;
`schedule-import.js` is the CSV reader it depends on.
```js
import { parseNameplate, parseEquipmentSchedule, candidatesFor, checkAgainst, statusOf } from './nameplate-model.js';
const reading = parseNameplate(`NORTHLINE POWER SYSTEMS
UNINTERRUPTIBLE POWER SUPPLY
MODEL NO: NPX-750-480
SERIAL NO: NL26A01937
INPUT: 480Y/277 VAC 3 PH 60 HZ
RATING: 750 KVA / 675 KW
INPUT CURRENT: 1002 A
MFG DATE: 03/2026`);
console.log(reading.type); // 'ups'
console.log(reading.fields.voltage); // { value: '480Y/277 V', values: [480, 277], conf, line }
const { items } = parseEquipmentSchedule(scheduleCsv);
const [best] = candidatesFor(reading, items);
console.log(statusOf(checkAgainst(reading, best.item), best.item.tag)); // 'verified' | 'partial' | 'mismatch' | …
```
In a browser, feed Tesseract's `data.lines` (`[{ text, confidence, bbox }]`) straight into `parseNameplate` to
keep OCR confidence and the plate line each value came from.
## Evaluation & reproducibility
- **Extraction:** `node tests/nameplates-extraction-bench.mjs --n=1000 --json=…` — labelled corpus, per-field
precision/recall/F1, whole-plate exact match, ms/plate. Corpus dump for other models:
`… --dump=…/extraction-corpus.jsonl`. Method and comparator: `ml/nameplates/bench/README.md`.
- **Unit tests:** the parser, voltage reader, code folding, schedule parsing, candidate ranking, mismatch
detection, range guards and the matcher — `node --test tests/nameplate-model.test.mjs` (all passing).
- **OCR end-to-end:** `node tests/nameplates-bench.mjs` — drawn plates through phone-photo degradations.
- **Fine-tuned reader:** `ml/nameplates/cloud/eval_donut.py` scores the Donut model field by field on the
held-out split.
## Repository contents
| File | What it is |
|---|---|
| `nameplate-model.js` | the extractor, matcher and register builder (ES module) |
| `schedule-import.js` | the CSV schedule reader it depends on |
| `progress-project.js` | a helper the schedule reader imports |
| `sample_schedule.csv` | a 10-row data-centre equipment schedule |
| `sample_plates.json` | sample plates: a match, a flagged mismatch, a switchboard, a server |
| `eval/` | OCR benchmark output, extraction benchmark output and corpus |
| `config.json` | machine-readable fields, groups, types and statuses |
## Provenance
An open extraction and verification engine from Constructelligence, the same code path that powers the
**Data Centre Construction** mode of BuildVision. No customer data is used; sample plates use fictional
makers and models.
It is the document-AI sibling of the vision models
[`construction-site-safety-hazards`](https://huggingface.co/constructelligence/construction-site-safety-hazards)
and [`electrical-circuit-connectivity`](https://huggingface.co/constructelligence/electrical-circuit-connectivity).
## Safety
This is a **prompt to look**, not a finding. It is not safety-rated, not a compliance decision, and not a
substitute for inspection by a competent person. Verify every flagged field against the physical plate before
acting on it.
## Licence and trademarks
Code released under **Apache-2.0**. Brand and product names (Schneider Electric, Eaton, Vertiv, Caterpillar,
Trane, Dell, Cisco, …) are trademarks of their owners and are matched only to identify user-supplied plates;
this project is independent and not affiliated with or endorsed by them.
## Citation
```bibtex
@misc{constructelligence_nameplates,
title = {Data Centre Construction: equipment-nameplate OCR checked against the equipment schedule},
author = {Constructelligence},
year = {2026},
howpublished = {\url{https://huggingface.co/constructelligence/data-centre-nameplates}}
}
```
|