PhyMRI-SR: Toward Physics-Aware MRI Image Super-Resolution

Published on Jul 7
· Submitted by
GONG JIA
on Jul 10
Authors:
,
,
,
,
,
,

Abstract

MR super-resolution is reformulated as a physics-aware reconstruction problem that dynamically adapts resolution-SNR configurations using Gaussian splatting with prior-aware representations and physics-constrained modeling.

Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs. We rethink MRI super-resolution as a physics-aware reconstruction problem, in which the goal is to identify the optimal resolution-SNR configuration and then super-resolve it to obtain high-quality MRI results. A key implication of this formulation is that MRI resolution becomes dynamic rather than fixed. To handle such resolution-heterogeneous inputs, we adapt 2D Gaussian Splatting (2D GS) to MRI by formulating reconstruction as a coordinate-based, resolution-agnostic rendering problem. To further enhance fidelity, we introduce three innovations: (1) a prior-aware Gaussian representation that combines an Anatomical Structure Prior for tissue-specific kernel initialization with an Imaging System Prior that captures hardware characteristics via a covariance dictionary; (2) a physics-constrained signal modeling scheme that predicts intrinsic tissue parameters (proton density rho and effective relaxation rate R2) and synthesizes intensities through governing physical equations, ensuring biophysically plausible contrast; and (3) a meta-learning framework that alleviates paired-data scarcity by pretraining on simulated data and adapting to real-world conditions. Extensive experiments on dynamic-resolution datasets and standard benchmarks demonstrate that our method achieves state-of-the-art performance, highlighting its strong potential for clinical deployment.

Community

Paper submitter

This paper reframes MRI super-resolution as a physics-aware problem, recognizing that resolution and SNR are inherently coupled in MRI acquisition, making resolution dynamic rather than fixed. The authors adapt 2D Gaussian Splatting as a resolution-agnostic representation and introduce physics-constrained signal modeling that predicts intrinsic tissue parameters (proton density and relaxation rate) to synthesize biophysically plausible images. A meta-learning framework addresses paired-data scarcity by pretraining on simulated data and adapting to real-world conditions, achieving state-of-the-art performance on both dynamic-resolution and standard benchmarks.

Sign up or log in to comment

Get this paper in your agent:

hf papers read 2607.06238
Don't have the latest CLI?
curl -LsSf https://hf.co/cli/install.sh | bash

Models citing this paper 0

No model linking this paper

Cite arxiv.org/abs/2607.06238 in a model README.md to link it from this page.

Datasets citing this paper 0

No dataset linking this paper

Cite arxiv.org/abs/2607.06238 in a dataset README.md to link it from this page.

Spaces citing this paper 0

No Space linking this paper

Cite arxiv.org/abs/2607.06238 in a Space README.md to link it from this page.

Collections including this paper 0

No Collection including this paper

Add this paper to a collection to link it from this page.