tristan-deep commited on
Commit
cfcf9e2
·
verified ·
1 Parent(s): dfcd9d9

waterloo-carotid: sync card and figures with GitHub #30

Browse files

Hero loop Acq90 -> Acq1 (frame 250), adds assets/main.png, refreshed reference reconstruction. Mirrors tristan-deep/OpenH-RF#30.

waterloo-carotid/README.md CHANGED
@@ -22,9 +22,9 @@ size_categories:
22
 
23
  # UW-Carotid RF
24
 
25
- ![Reconstructed cineloop from Acq90.hdf5](assets/Acq90.gif)
26
 
27
- *Cine loop of [`data/Acq90.hdf5`](https://huggingface.co/datasets/nvidia/OpenH-RF/blob/main/waterloo-carotid/data/Acq90.hdf5), reconstructed from the raw channel data with the `pipeline.yaml` in this folder.*
28
 
29
  ## Dataset Description
30
 
@@ -35,7 +35,7 @@ Raw RF frames (plane wave) and vector flow profiles of the human carotid arterie
35
  - Hassan Nahas <hassan.nahas@uwaterloo.ca>
36
  - Jason Y. -H. Hsu <jason.hsu@uwaterloo.ca>
37
  - Theresa Gu <theresa.gu@uwaterloo.ca>
38
- - Adrian J. Y. Chee
39
  - Alfred C. H. Yu <alfred.yu@uwaterloo.ca>
40
  - LITMUS, University of Waterloo
41
 
@@ -65,7 +65,7 @@ The acquisitions can be processed with the `pipeline.yaml` definition in this fo
65
 
66
  ```bash
67
  zea process \
68
- --dataset hf://nvidia/OpenH-RF/waterloo-carotid/data/Acq90.hdf5 \
69
  --config hf://nvidia/OpenH-RF/waterloo-carotid/pipeline.yaml \
70
  --n-frames 1 \
71
  --save-as png
@@ -106,24 +106,13 @@ Per-sample contents of the converted HDF5:
106
 
107
  All `coordinates` arrays are per-pixel Cartesian positions in meters, last axis `[x, y, z]` (y = 0 for 2-D maps).
108
 
109
- ## Shipped Example Acquisitions
110
-
111
- Two example acquisitions are included under `hdf5/` as a representative subset of the full dataset:
112
-
113
- | File | Subject | Anatomy | View | Condition | Frames |
114
- |---|---|---|---|---|---|
115
- | `hdf5/Acq0.hdf5` | 1 | Common Carotid Artery | Longitudinal | Baseline | 500 |
116
- | `hdf5/Acq62.hdf5` | 1 | Internal Carotid Artery | Cross-sectional | Baseline | 500 |
117
-
118
- Each common carotid artery frame comprises 2 steered plane-wave transmits (`n_tx = 2`), 2048 axial samples, and 128 receive channels. Each internal carotid artery frame comprises 1 steered plane-wave transmits (`n_tx = 1`), 1536 axial samples, and 128 receive channels.
119
-
120
- The frame count in these examples is truncated for demonstration; full acquisitions contain the frame counts described below.
121
-
122
  ## Dataset Quantification
123
 
124
  **Current OpenH-RF release:** 93 HDF5 files; 6.90 TB (6,902,089,770,179 bytes) stored; root `zea_version` **0.1.4**. Sizes include all HDF5 contents and use decimal units (MB = 10^6 bytes, GB = 10^9 bytes, TB = 10^12 bytes), not decoded-array memory or original-source download sizes.
125
 
126
- Data was collected from 8 participants, spanning carotid arteries (Common Carotid Artery and Internal Carotid Artery) in both longitudinal and cross-sectional views. In total, the dataset consists of 93 acquisitions, containing 30,000 or 36,000 frames of raw RF data per acquisition (47 acquisitions of 30,000 frames and 46 of 36,000 frames).
 
 
127
 
128
  ## Subject Metadata
129
 
@@ -150,10 +139,10 @@ Data was collected from 8 participants, spanning carotid arteries (Common Caroti
150
  - **Dual Angle-Compounding:** Beamforming for B-mode and power Doppler is performed twice with opposite receive angles ($+15^{\circ}$ and $-15^{\circ}$). The final high-resolution beamformed image (HRI) is the average of these two acquisitions:
151
  $$HRI = \frac{HRI_{+15^{\circ}} + HRI_{-15^{\circ}}}{2}$$
152
  - **Reconstruction Grid:** Cartesian coordinates mapped by a `PixelMap` representing a lateral range of $[-19, 19]\text{ mm}$ and axial depth of $[0, 30]\text{ mm}$ at $0.1\text{ mm}$ spatial resolution.
153
- 3. **Clutter Filtering:** Clutter filtering is performed on the beamformed ensemble using a high-pass wall filter (normalized cut-off frequencies of 0.1 and 0.15, filter length of 100).
154
  4. **Multi-Angle Doppler Frequency Estimation:** Angle-specific Doppler frequencies are computed using an ensemble size of 64 frames with a step size of 1.
155
- - For acquisitions with 2 tx angles, we used the following Tx-Rx angles: Tx: [-10, -10, 10, 10]; Rx: [-10, 10, -10, 10]
156
- - For acquisitions with 1 tx angle: Tx: [-10, -10, -10]; Rx: [-10, 0, 10]
157
  5. **Vector Doppler Velocity Estimation:** Lateral ($v_x$) and axial ($v_z$) velocity components are computed from the multi-angle Doppler frequency estimates using least-squares estimation.
158
 
159
  The full LITMUS processing pipeline (GPU DAS beamforming + multi-angle vector Doppler) is documented by the contributors. That documentation is provided for provenance and reproducibility; it depends on the LITMUS core Python package and the raw acquisition frames, so it is not runnable from this folder alone.
 
22
 
23
  # UW-Carotid RF
24
 
25
+ ![Reconstructed cineloop from Acq1.hdf5](assets/Acq1.gif)
26
 
27
+ *Cine loop of [`data/Acq1.hdf5`](https://huggingface.co/datasets/nvidia/OpenH-RF/blob/main/waterloo-carotid/data/Acq1.hdf5), rendered using provided velocity fields.*
28
 
29
  ## Dataset Description
30
 
 
35
  - Hassan Nahas <hassan.nahas@uwaterloo.ca>
36
  - Jason Y. -H. Hsu <jason.hsu@uwaterloo.ca>
37
  - Theresa Gu <theresa.gu@uwaterloo.ca>
38
+ - Adrian J. Y. Chee <adrian.chee@uwaterloo.ca>
39
  - Alfred C. H. Yu <alfred.yu@uwaterloo.ca>
40
  - LITMUS, University of Waterloo
41
 
 
65
 
66
  ```bash
67
  zea process \
68
+ --dataset hf://nvidia/OpenH-RF/waterloo-carotid/data/Acq1.hdf5 \
69
  --config hf://nvidia/OpenH-RF/waterloo-carotid/pipeline.yaml \
70
  --n-frames 1 \
71
  --save-as png
 
106
 
107
  All `coordinates` arrays are per-pixel Cartesian positions in meters, last axis `[x, y, z]` (y = 0 for 2-D maps).
108
 
 
 
 
 
 
 
 
 
 
 
 
 
 
109
  ## Dataset Quantification
110
 
111
  **Current OpenH-RF release:** 93 HDF5 files; 6.90 TB (6,902,089,770,179 bytes) stored; root `zea_version` **0.1.4**. Sizes include all HDF5 contents and use decimal units (MB = 10^6 bytes, GB = 10^9 bytes, TB = 10^12 bytes), not decoded-array memory or original-source download sizes.
112
 
113
+ Data was collected from 8 participants, spanning carotid arteries (Common Carotid Artery and Internal Carotid Artery) in both longitudinal and cross-sectional views. In total, the dataset consists of 93 acquisitions, containing 30,000 or 36,000 frames of raw RF data per acquisition (47 acquisitions of 30,000 frames and 46 of 36,000 frames).
114
+ Each common carotid artery frame comprises 2 steered plane-wave transmits (`n_tx = 2`), 2048 axial samples, and 128 receive channels. Each internal carotid artery frame comprises 1 steered plane-wave transmits (`n_tx = 1`), 1536 axial samples, and 128 receive channels.
115
+
116
 
117
  ## Subject Metadata
118
 
 
139
  - **Dual Angle-Compounding:** Beamforming for B-mode and power Doppler is performed twice with opposite receive angles ($+15^{\circ}$ and $-15^{\circ}$). The final high-resolution beamformed image (HRI) is the average of these two acquisitions:
140
  $$HRI = \frac{HRI_{+15^{\circ}} + HRI_{-15^{\circ}}}{2}$$
141
  - **Reconstruction Grid:** Cartesian coordinates mapped by a `PixelMap` representing a lateral range of $[-19, 19]\text{ mm}$ and axial depth of $[0, 30]\text{ mm}$ at $0.1\text{ mm}$ spatial resolution.
142
+ 3. **Clutter Filtering:** Clutter filtering is performed on the beamformed ensemble using a high-pass wall filter (normalized cut-off frequencies of 0.1 and 0.15, attenuation of 100 db).
143
  4. **Multi-Angle Doppler Frequency Estimation:** Angle-specific Doppler frequencies are computed using an ensemble size of 64 frames with a step size of 1.
144
+ - For acquisitions with 2 tx angles, we used the following Tx-Rx angles: Tx: [-10°, -10°, 10°, 10°]; Rx: [-10°, 10°, -10°, 10°]
145
+ - For acquisitions with 1 tx angle: Tx: [-10°, -10°, -10°]; Rx: [-10°, 0°, 10°]
146
  5. **Vector Doppler Velocity Estimation:** Lateral ($v_x$) and axial ($v_z$) velocity components are computed from the multi-angle Doppler frequency estimates using least-squares estimation.
147
 
148
  The full LITMUS processing pipeline (GPU DAS beamforming + multi-angle vector Doppler) is documented by the contributors. That documentation is provided for provenance and reproducibility; it depends on the LITMUS core Python package and the raw acquisition frames, so it is not runnable from this folder alone.
waterloo-carotid/assets/{Acq90.gif → Acq1.gif} RENAMED
File without changes
waterloo-carotid/assets/main.png ADDED

Git LFS Details

  • SHA256: 16bcc813572089e65af87e72c41c70c2d4ce307eb8b065ce185b8342e45e9d77
  • Pointer size: 131 Bytes
  • Size of remote file: 255 kB
waterloo-carotid/assets/reconstruct_output.png CHANGED

Git LFS Details

  • SHA256: 0d0407f9fc4b1bb6c522ca29d862d70297942c601d179228754fc51edf0e1cb3
  • Pointer size: 131 Bytes
  • Size of remote file: 380 kB

Git LFS Details

  • SHA256: 928d8153e200aa935c32166a8d09235928a74d0531d0924b58d48e53567022ce
  • Pointer size: 131 Bytes
  • Size of remote file: 429 kB