| .oO Phrack 49 Oo. |
|
|
| Volume Seven, Issue Forty-Nine |
|
|
| 11 of 16 |
|
|
|
|
| A listing of South Western Bell Lineman Work Codes |
|
|
| Written by: Icon |
|
|
| Have you ever wanted to bullshit a telco employee but you don't |
| have the proper acronym or code that would help convince them? Well here |
| is a nearly complete listing of all of the Disposition Codes that I found |
| on a trash run. Enjoy... |
|
|
| |
| -= Disposition Codes =- |
|
|
|
|
| [The following is an exact word for word type up] |
|
|
| Disposition Code 01XX - Station Set, Business Services: |
| This code applies to all troules located in TELCO-provided station set |
| equipment, including the mounting cord and handset cord, when used for OCS |
| classes of service. |
|
|
| Disposition Code 02XX - Other Station Equipment, OSC Business Services |
| (or Public Services): |
| This code applies to all troubles in station equipment (other than station |
| sets) including switchboards, PBX systems, switching equipment on the |
| customer premises, etc. and to Public Services (COIN) station equipment. |
|
|
| Disposition Code 03XX - Station Wiring |
| 0310 Premise Termination: Coin/Coinless |
| 0370 Network Termination: Other |
| 0371 Protector: Applies when trouble is located in a protective interface |
| 0373 Network Interface: Applies when trouble is located in network interface |
| 0375 Network Terminating Wire: Applies when trouble is located in the wire |
| between the protector/cable termination and the network interface of |
| demarcation |
| 0378 Side Wall - Jumper missing |
| 0379 Side Wall - Jumper wrong |
| 0380 Drop Other |
| 0381 Aerial-Paired: Applies to trouble located in one-pair aerial drop |
| service wire |
| 0382 Aerial-Multiple: Applies to trouble located in multiple-paired aerial |
| drop service wire |
| 0383 Buried Drop - Repaired Initial Dispatch: Applies to trouble located in |
| buried drop and total repaired on first dispatch |
| 0384 Buried Drop - Temporary Places, No Recon: Applies to trouble located in |
| buried drop and a subsequent visit is not needed for drop retermination |
| 0385 Buried Drop - Temporary Placed, Recon Required: Applies to trouble |
| located in buried drop and a subsequent visit is needed for drop |
| placement and recon. |
| 0386 Drop, Left In: Applies to trouble located in a drop terminated to the |
| cable pair at a location other than that of the subscriber's |
| 0387 Drop Reversed |
| 0388 Buried Drop - Drop Not Buried: Applies when temporary drop is removed |
| and newly placed buried drop is reconned |
| 0389 Temporary Drop Not Buried - Repaired: Applies to trouble located in the |
| temporary drop and it is repaired |
| 0390 Network Miscellaneous Apparatus |
|
|
| Disposition Code 04XX - Outside Plant |
| 0401 Pair Transferred - Defective Pair Left: Applies when service is restored |
| by transferring the customer's service to a different cable pair and the |
| original defect is not corrected. |
| 0402 Pair Cut Dead To The Field: Applies when service is restored by removing |
| faulted conductor bridge tap which has affected the customer's service |
| and the original defect is not corrected |
| 0403 Pair Transposed: Applies when conductors are transposed between two or |
| more points to restore customer service and the original defect is not |
| corrected |
| 0404 Defective Section/Temporary Drop Placed: Applies when trouble is located |
| and a drop is placed as a temporary cable between terminals. |
| 0405 Defective Pair - Encapsulated Plant: Applies when trouble is |
| encapsulated plant and pair is not fixed |
| 0407 Pair Transferred - No Defective Pair Left: Applies when service is |
| restored by transferring the customer's service to a different cable pair |
| (usually for record purposes) and no defective pair is involved (i.e., |
| pair left off cable transfer, telephone number assigned on wrong pair). |
| 0410 Cable Other: Applies when the trouble is fixed in the cable facility not |
| listed elsewhere |
| 0411 Sheath: Applies when damaged cable sheath or turnplate must be repaired |
| to clear a trouble report |
| 0412 Cut Cable: Applies when a cable has been cut or damaged and must be |
| repaired to clear trouble reports |
| 0413 Wet Cable: Applies when a cable has gotten wet and must be dried and/or |
| cutaround to clear trouble reports |
| 0416 Conductor: Applies when trouble is located in cable conductors, such as |
| defective insulation, etc. |
| 0420 Closure/Splice Case: Applies when trouble is located in cable closures |
| and splice cases |
| 0421 Temporary Closure: Applies to trouble located in temporary type closures |
| 0423 Encapsulated: Applies to a trouble located within an encapsulated splice |
| or closure. Includes troubles resulting from a defect in material, |
| workmanship during construction, or maintenance activities of an |
| encapsulated splice |
| 0426 Ready Access Splice Case: Applies to trouble found in a ready access |
| type splice case |
| 0430 Terminal - Other: Applies to trouble found in a terminal not otherwise |
| listed |
| 0431 Ready Access Terminal, All: Applies to trouble found in ready access |
| type terminals in aerial or buried plant |
| 0433 Fixed Count Terminal, All: Applies when trouble is located in fixed |
| count terminal in aerial or buried plant |
| 0436 Cross Box, RAI/SAI: Applies when trouble is located in a serving area |
| interface or FX box |
| 0440 Wire/Dual Plant - Other: Applies when trouble is located in wire or dual |
| wire plant not elsewhere listed |
| 0442 Open/Rural Wire: Applies when trouble is located in wire for |
| distribution, i.e., open wire, c-rural wire, and d-underground wire |
| 0470 Pair Gain System: Applies when trouble is located in the Remote Terminal |
| of the pair gain system |
| 0471 Repeater Failure: Applies when trouble is located in the repeater of a |
| Pair Gain System |
| 0472 Battery Failure: Applies when trouble is located in the battery of a |
| Pair Gain System |
| 0473 Common Circuit Pack: Applies when trouble is located in the common |
| circuit pack of a Pair Gain System |
| 0474 Channel Unit Exchange: Applies when trouble is located in the channel |
| unit (exchange type) |
| 0475 Channel Unit Special: Applies when trouble is located in the channel |
| unit (special type) |
| 0476 Routing: Applies when trouble is with the routing |
| 0477 Rectifier Failure: Applies when trouble is caused by rectifier failure |
| 0478 Wiring: Applies when trouble is caused by the wiring |
| 0470 Commercial Power Failure: Applies when trouble is caused because of |
| commercial power failure |
| 0480 Cable Miscellaneous/Other |
| 0481 Pole/Guy/Anchor/Trench: Applies when a trouble is the result of a pole, |
| guy, anchor, route signs, or trench associated with outside plant |
| 0483 Fiber Optics - All: Applies when a trouble is the result of conditions |
| associated with fiber optics |
|
|
| Disposition Code 05XX - Central Office |
| 0511 Common Equipment |
| 0512 Linkage/Network/Grid |
| 0513 Line Equipment |
| 0514 Billing Equipment |
| 0515 Trunk |
| 0516 Public Service Trunk |
| 0520 Translations - Other |
| 0521 Generic Work Error |
| 0522 Generic Program Error |
| 0523 Parameter - Work Error |
| 0524 Parameter - Document Error |
| 0525 Line - Work Error |
| 0526 Line - Document Error |
| 0527 Network - Work Error |
| 0528 Network - Document Error |
| 0530 Intercept or Disconnect Document Error |
| 0531 MDF Cross-Connection Missing |
| 0532 MDF Cross-Connection Broken |
| 0533 MDF Cross-Connection Work Error |
| 0534 MDF Cross-Connection Document Error |
| 0535 Other Cross-Connection Work Error |
| 0536 Other Cross-Connection Document Error |
| 0537 Billing Cross-Connection Work Error |
| 0538 Billing Cross-Connection Document Error |
| 0539 Intercept or Disconnect Work Error |
| 0540 Other Frame |
| 0541 Defective or operated protector |
| 0542 Missing Protection Device |
| 0543 Reversing Device |
| 0544 Terminal - Wire Clipping |
| 0545 Terminal Connection |
| 0546 Test Cord |
| 0550 Other Power |
| 0551 DC Power Equipment |
| 0552 AC Power Equipment |
| 0553 Ringer Plant |
| 0554 Standby Emergency Power |
| 0560 Miscellaneous Equipment - Other |
| 0561 Radio System |
| 0562 Line Testing Equipment |
| 0563 Concentrator |
| 0564 Range Extender - Applies when a report is the result of a defective |
| range extender |
| 0565 Carrier System |
| 0566 Automatic Message Accounting Recording Center |
| 0580 Pair Gain System/RSS Other |
| 0583 Common Circuit Pack |
| 0584 Channel Unit Exchange |
| 0585 Channel Unit Special |
| 0586 Carrier Unit Replaced (AML/SLC-1) |
| 0587 Power |
| 0588 Wiring |
|
|
| Disposition 06XX - Customer Action |
| 0600 Customer Action: Applies when a trouble report results from customer |
| error or misuse of features in connection with custom calling service |
|
|
| Disposition 07XX - Test OK |
| 0701 MC Retest Ok |
| 0708 SCC Test Ok |
| 0711 Test OK (Maintenance Center Use Only) |
| 0715 Customer Cancel Original (CSB Use Only) |
| 0717 Lead Test Ok |
| 0720 Link Retest Ok |
| 0730 Test OK TAN (Technician Use) |
| 0747 Test OK (Front End Closeout) |
| 0750 CSB Retest OK |
|
|
| Disposition Code 08XX - Found OK - In |
| 0800 Found OK - In |
|
|
| Disposition Code 09XX - Found Ok - Out |
| 0901 Found OK - Out, Non-Cable: Applies when trouble condition is determined |
| to be FOK between the serving terminal and the customer's side of the |
| protector/network interface |
| 0910 Found Ok - Out, Cable: Applies when trouble condition is determined to |
| be FOK between the serving terminal and the field side of the central |
| office |
|
|
| Disposition Code 10XX - Referred Out |
| 1001 Referred Out: Applies when trouble reports are referred to other |
| Maintenance Centers, agencies or departments not normally involved in |
| the trouble clearing effort |
|
|
| Disposition Code 12XX - Customer Provided Equipment |
| 120X Voice Messaging Service |
| 1201 Voice Messaging Service 0 All |
| 121X Maintenance Contract (Inline/Inline Plus) |
| 1210 Cord: Customer has maintenance contract and a defective mounting cord was |
| replaced |
| 1211 Loaner Set Provided: Applies to those customers with an inline+ |
| agreement, in which a loaner set is provided, or when the customer |
| chooses to buy the replacement set |
| 1212 Inline Only - Set Trouble: Applies to customer with a maintenance |
| agreement for IW only and the trouble is located in the set/equipment. |
| This code includes, but is not limited to receiver off hook, unplugged |
| sets, defective sets |
| 1213 Non-Standard IW (Customer Repair): Applies when the customer has an |
| agreement for standard IW maintenance; however, the trouble is located |
| in non-standard IW and the customer will repair. NO CHARGE |
| 1214 Inside Wire: Applies to customers with an IW maintenance agreement and |
| the technician repairs the IW. NO CHARGE |
| 1215 Non-Standard IW (Telco Replaced): Applies when the customer has a |
| maintenance contract for standard IW maintenance; however, the trouble is |
| located in non-standard IW and the technician will repair. PREMISES |
| WORK CHARGE IS APPLICABLE |
| 1217 No Access - Field Use: Applies on second no access, no trouble is found |
| at the customer premise |
| 1218 Inline/Inline Plus - Telco Fix Exceptions: Wire repair due to acts of |
| God, such as floods, earthquake, riot, gross negligence, willful |
| damage/vandalism. Also wire that does not meet SWBT installation practice |
| technical standards, or is not in satisfactory condition |
| 1219 Inline/Inline Plus - Customer Fix - Exceptions (See 1218 for exceptions) |
| 122X CPE - Other (No Maintenance Contract) |
| 1220 Radio Suppresser (Inline Customer): Applies when a radio suppresser is |
| placed to resolve the trouble |
| 1221 Calling Party Hold: Applies when the trouble condition is a result of |
| calling party hold. NO CHARGE |
| 1222 Set/Equipment: Applies when then trouble condition is determined by the |
| technician to be caused by the customer telephone set/equipment. No |
| maintenance agreement. A MAINTENANCE OF SERVICE CHARGE WILL APPLY |
| 1223 CPE (IW/CPE) No Dispatch: Applies when trouble is tested, but is |
| determined to be in CPE via conversation with the customer and/or related tests. No repair dispatch is made. NO CHARGE |
| 1225 Receiver Off Hook: Applies when trouble is tested when cannot be located |
| in Telco facilities and the trouble report or service condition can be |
| attributed to a receiver off hook. MSC WILL APPLT |
| 1226 Set Unplugged: Applies when trouble is tested which cannot be located in |
| Telco facilities and the trouble report or service difficulty can be |
| attributed to unplugged CPE. MSG WILL APPLY |
| 1227 Public Extension (SEMI): Applies when trouble is tested which cannot be |
| located in TELCO facilities and the trouble report or service condition |
| can be attributed to semi-public extension. Semi-public extension is |
| defined as a CPE instrument used as an extension on Telco provided coin |
| service. MSC WILL APPLY |
| 1228 Private Coin Service: Applies when trouble is tested which cannot be |
| located in Telco facilities and the trouble report or service condition |
| can be attributed to private coin service. Private coin service is |
| defined as a coin instrument and associated wire provided by a non-Telco |
| 1229 Cable Facilities (Not Telco Maintained): Applies when trouble is tested |
| which cannot be located in Telco facilities and the trouble report or |
| service condition can be attributed to CPE cable facility. MSC WILL APPLY |
| 123X Intexchange Carrier |
| 1231 Intexchange Carrier: Applies when trouble is tested which cannot be |
| located in Telco facilities or equipment and the services are provided |
| by an IC |
| 124X Unauthorized CPE/Usage/Tariff Violation |
| 1241 Dispatched trouble reports involving CPE that were installed under |
| Contract I/M services, and are within the warranty time period, should |
| be closed to disposition code 12410 Contract I/M services, CPE. The |
| disposition code 122X should not be used under these circumstances. NO |
| REPAIR CHARGE (MSR or RSC) or TIME SENSITIVE CHARGES APPLY |
| 1242 Dispatched trouble reports involving inside wire within the warranty time |
| period of the Contract I/M Services contract between SWT/SWBT should be |
| closed to the appropriate disposition code 121X. Inside wire troubles |
| reported by Non-Inline and Non-Contract I/M Services customers should |
| continue to be closed to the appropriate disposition code 126X and |
| normal charges should apply. |
|
|
| Disposition 12XX - Customer Provided Equipment |
| 126X Time Sensitive Work/Isolation/No Maintenance Contract |
| 1261 Inside Wire - Telco Repair: Applies when trouble is tested which cannot |
| be located in Telco facilities and a trouble report or service condition |
| is attributed to the IW. The technician repairs the IW for an ADDITIONAL |
| CHARGE to the customer. (Time Sensitive - Repair Rates). |
| 1262 Inside Wire - SNI Not Available Cust Fix (Non-Inline): Applies when |
| trouble is tested which cannot be located in Telco Facilities and the |
| trouble report is isolated to the customer's side of the protector. The |
| technician installs a Network Interface but does not repair the trouble |
| 1263 Inside Wire - SNI Available - Cust Fix (Non-Inline): Applies when trouble |
| is tested which cannot be located in Telco facilities and a trouble |
| report or service condition is in attributed to the CPE. A Network |
| Interface is in place and the customer does the repair |
| 1264 No Authorization/Customer Repair: Applies when trouble is tested which |
| cannot be located in Telco facilities and a trouble repor or service |
| condition can be attributed to CPIW. Premise access is obtained and |
| customer/customer's agent is unable to authorize repair charge. |
| 1265 Military Facility: Applies when trouble is isolated to I/W maintained by |
| military maintenance personnel. |
| 1266 NA for Non-Inline (Field Use) |
| 1267 CPE - No Access Subscriber Follow-up (MC USE ONLY): Applies when trouble |
| cannot be located in Telco facilities and a trouble report or service |
| condition is attributed to the CPE. The technician does not have access |
| to the customer's premise, but a network interface is present. |
| 1268 Warranty: Applies when trouble is tested which cannot be located in |
| Telco facilities but repair work is performed by the technician within |
| 30 days of previous IW repair performed by Telco. (Proof of warranty is |
| the customer's responsibility). A SERVICE CHARGE IS NOT APPLICABLE |
| 127X Administrative Reports - Do Not Bill |
| 1275 Predictor/Scan/CPR: Applies when a trouble condition is detected by SCAN/ |
| PREDICTOR or Calling Party Report, a dispatch is made and no work is |
| performed. The trouble condition is attributed to the CPE. (A SERVICE |
| CHARGE IS NOT APPLICABLE) |
| 128X CSB Use Only |
| 1281 Front End Close Out (Customer Service Bureau Only): Apples when a |
| trouble report is determined to be caused by the CSB. The CSB will close |
| out this report with this disposition code. |
| Disposition Code 129X MOOSA (Maintenance Center Use Only) |
| 1291 MOOSA Error Corrections |
|
|
| Disposition Code 13XX |
| 1301 Other Departments - Telco |
| 1302 Non Telco |
| 1303 Wrong Number Reported |
| 1325 Service Order Worked - Link |
| 1326 Service Order Cancel/Delay |
| 1327 Service Order Changes |
|
|
| Disposition Code 20XX - Air Pressure |
| 2010 Transducer |
| 2011 Contactor |
| 2012 Pressure Plug |
| 2013 Air Flow Sensor |
| 2014 Pipe |
| 2015 Manifold or Tubing |
| 2016 Dryers |
| 2017 Air Bottles |
| 2018 Fittings |
|
|
| Disposition Code 30XX - Cable Location |
| 3010 Patrols and Inspections |
| 3011 Facility Located |
| 3012 No Facilities In Area |
|
|
|
|
|
|