| Information about Northern Telecom's FMT-150B/C/D |
| Written by StaTiC |
| (statik@free.org) |
| --------------------------------------------------------------------------- |
|
|
| Ok, I know someone wrote an article in Phrack about the |
| FMT-150B/C/D, but I figured I should write some more. I am not going to |
| write the same info that FyberLyte wrote, in fact I recommend you go and |
| check it out. It is in Phrack #44-13. This is some stuff I obtained, |
| that I figured the rest of the world would be interested in. |
|
|
| Included info: Connecting a FMT-150 to a Rockwell OS-35 |
| Connecting Environmental Alarms to the FMT-150 |
| Procomm Script to Perform Configuration of FMT-150 |
| FMT-150 Configuration Checklist |
| Glossary of Terms |
|
|
|
|
| ------------------------------------------------------------------------------ |
|
|
| INSTRUCTIONS FOR X-CONNECTING FMT-150 CUSTOMER OUTPUT TO |
| ROCKWELL OS-35 INPUTS |
|
|
| A pin block will be provided at the central office location, in the |
| bay equipped with FMT-150 equipment. The pin block will provide |
| the termination points for the Rockwell OS-35A and the FMT-150 |
| customer output alarms. Each pin block will be able to support a |
| maximum of 16 FMT-150 systems, see pin block diagram. |
|
|
| Wiring of the FMT-150 customer outputs points and the OS-35A points |
| will be done by the vender on the back of the pin block. |
|
|
| Once a FMT-150 system has been certified the certification team |
| will be responsible for x-connecting the FMT-150 customer output |
| alarm points to the appropriate OS-35A points on the front of the |
| pin block. Completion of this x-connecting will allow FMT-150 |
| system alarms originating either from the CO or the RT to be |
| transported via the OS-35A back to the Lightwave and Radio Alarm |
| Center. |
|
|
| IMPORTANT, MBT CERTIFICATION TEAMS X-CONNECT ONLY THE FMT-150 THAT |
| IS BEING PUT INTO SERVICE AND ONLY AFTER THE ELECTRONICS ARE |
| CERTIFIED. |
|
|
| The FMT-150 16 customer outputs are defined as follows: |
|
|
| OUTPUT ALARM OUTPUT ALARM |
| ------ ----- ------ ----- |
| 1 BAY MAJOR 9 MI3 ALARM #3 |
| 2 BAY MINOR 10 HSA ALARM |
| 3 OPT A FAIL 11 HSB ALARM |
| 4 OPT B FAIL 12 DS1 GRP FAIL |
| 5 STX TX 13 SYSTEM ID CLLI |
| 6 STS RX 14 COMM. EQUIP. ALARM |
| 7 M13 ALARM #1 15 NODE #1 CO |
| 8 M13 ALARM #2 16 NODE #2 REMOTE |
|
|
| The Rockwell OS-35A provides a total of 32 separate alarm points. |
| The first 16 points with the exception of point 13 have been |
| multiplied on the pin block to provide x-connect points for a total |
| of 16 FMT-150 systems, see pin block diagram. |
|
|
| On the pin block x-connect the designated (1 of 16) FMT-150 system |
| customer outputs, pins 1-12 and 14-16 to the appropriate OS-35A |
| pins 1-12 and 14-16, see pin block diagram. |
|
|
| Pins 17-32 on the pin block going to the OS-35A will be used for |
| x-connecting the customer output #13 from each FMT-150 system. |
| Customer output #13 provides the system ID for the FMT-150, see pin |
| block diagram. |
|
|
| X-CONNECT CUSTOMER OUTPUT #13 FROM FMT-150 SYSTEMS IN |
| THIS SEQUENCE |
|
|
| OS-35A FMT-150 System |
| ------ -------------- |
| PIN 17 SYSTEM 1 |
| PIN 18 SYSTEM 2 |
| : : |
| : : |
| PIN 31 SYSTEM 15 |
| PIN 32 SYSTEM 16 |
|
|
| AGAIN, WIRE ONLY THE FMT-150 SYSTEM THAT IS BEING PUT INTO SERVICE |
| AND ONLY AFTER CERTIFICATION OF ELECTRONICS HAVE BEEN COMPLETED. |
|
|
| After x-connects have been completed on FMT-150 system that has |
| been certified, contact the Alarm Center at (313) 223-9688 and |
| verify that all 16 customer output alarm conditions at both the CO |
| and RT can be activated and are reporting via the OS-35A back to |
| the alarm center. |
|
|
| The Lightwave Alarm Center will monitor the FMT-150 system for a 24 |
| hour quiet period for alarms. During this 24 hour period if no |
| alarms are detected by the Lightwave Alarm Center, the FMT-150 will |
| be considered certified for alarming and ready for continual |
| monitoring. |
|
|
| If during the 24 hour quiet period the alarm center receives alarms |
| from the FMT-150 system, it will not be certified for continual |
| monitoring and it will be the responsibility of the MBT |
| Certification Teams to resolve those alarms. |
|
|
|
|
| ---------------------------------------------------------------------------- |
|
|
| INSTRUCTIONS FOR CROSS CONNECTING ENVIRONMENTAL ALARMS TO |
| THE FMT-150 INPUTS. |
|
|
| Environmental alarms at remote locations may be connected to the |
| FMT-150 customer inputs. If more than one system exists, these |
| alarms should only be connected to the first. Since many remotes |
| will not be equipped with all of these alarms, a checklist has been |
| provided on the system acceptance sheets to indicate which have |
| been wired. The alarms provided for are Smoke Detector, Sump Pump, |
| Open Door, AC Power Fail, HI-LO Temperature, Rectifier Fail, and |
| Battery Float. These are wired to pins D8 through E9 on the |
| FMT-150 backplane. See Shelf Backplane Detail, attached. |
|
|
| All Customer Inputs are software connected to Customer Output #12. |
| They will also bring in Bay Minor (Output #1) or Bay Major (Output |
| #2) as appropriate. Inputs #1 (Smoke Detector) and #2 (Sump Pump) |
| are latching inputs that can only be cleared by accessing the MCU |
| with a VT100 terminal. See Section 321-3211-01, DP 3003, page 2. |
|
|
| FMT-150 systems using external inputs for environmental alarms and |
| which use E2 telemetry rather than the OS-35 MUST be provided with |
| type NT7H90XH Maintenance Control Units at both ends. |
|
|
| External alarm operation and telemetry if equipped, should be |
| verified with the Alarm Center during acceptance. |
|
|
|
|
|
|
|
|
| -------------------------------------------------------------------------- |
| Procomm Script for Accessing FMT-150B/C/D |
|
|
| ;********************************************************************** |
| ;* * |
| ;* FMT150.CMD Version 5.00 Dec 18, 1990 * |
| ;* Please Destroy all previous versions of this program! * |
| ;* * |
| ;* NOTE: Procomm is a product of Datastorm Technologies * |
| ;********************************************************************** |
| ; |
| ; The script FMT150.CMD was written to automatically perform |
| ; all configuration commands for the Northern Telecom FMT-150 |
| ; fiber optic multiplexer. Specifically, this script will |
| ; complete over 125 configuration commands (performance |
| ; threshold, error correction, and alarm outputs) as outlined |
| ; in Section 4 of the Michigan Bell Certification Procedure for |
| ; the FMT-150. This program is compatible with all |
| ; certification requirements for FMT-150 MCU NT7H90XA or MCU |
| ; NT7H90XE. |
| ; |
| ; Requirements: |
| ; 1) Toshiba T1000 craft terminal or DOS equivalent. |
| ; 2) Proper serial cables and adapters. |
| ; 3) Procomm disk with FMT150.CMD file. |
| ; |
| ; Procedure for use: |
| ; 1) Remove disk from drive, then turn on computer. When the DOS |
| ; prompt appears insert the PROCOMM disk into disk drive. |
| ; Enter the command "A:" + <ENTER>. |
| ; 2) Enter the command "FIXPRN" + <ENTER>. |
| ; 3) Enter the command "PROCOMM" + <ENTER>. |
| ; 4) While holding the <ALT> key down, press the <D> key, |
| ; and select FMT-150 from the dialing menu. |
| ; 5) Gain access to MCU as normal (press the <ENTER> key 3 times). |
| ; 6) Once logged in, reset the MCU to factory default by |
| ; entering "M"(aintenance) "R"(eset) "*"(all) + <ENTER>. |
| ; It will take approximately three minutes to reconfigure. |
| ; 7) Gain access to MCU again as in steps 3) & 4). |
| ; 8) Select the script by pressing <ALT><F5> keys simultaneously. |
| ; 9) When prompted for command file enter "FMT150" + <ENTER>. |
| ; 10) Answer questions and away you go! |
| ; |
| ; HISTORY: Version 4.00 May 15, 1990 by AQW final release version |
| ; HISTORY: Version 4.10 Aug 08, 1990 by JBH mod to use VPRINT to divert |
| ; printer into a better bit bucket, and to correct callback #. |
| ; HISTORY: Version 4.12 Nov 21, 1990 by EEE to use Customer Inputs |
| ; HISTORY: Version 5.00 Dec 18, 1990 by JBH to update documentation |
| ;SN051690000 |
| ;REFNO=5.00 |
| CLEAR |
| PAUSE 1 |
| ALARM 1 |
| MESSAGE " " |
| MESSAGE " *************************************************" |
| MESSAGE " * *" |
| MESSAGE " * FMT-150 MCU NT7H90XC\CA CONFIGURATION PROGRAM *" |
| MESSAGE " * MCU NT7H90XE\EA CONFIGURATION PROGRAM *" |
| MESSAGE " * *" |
| MESSAGE " * VERSION 5.00 DEC 18, 1990 *" |
| MESSAGE " * *" |
| MESSAGE " * MICHIGAN BELL TELEPHONE COMPANY *" |
| MESSAGE " * A DIVISION OF AMERITECH *" |
| MESSAGE " * *" |
| MESSAGE " * *" |
| MESSAGE " *************************************************" |
| MESSAGE " " |
| MESSAGE " " |
| MESSAGE " ....TO EXIT THIS PROGRAM AT ANY TIME, PRESS <ESC>...." |
| PAUSE 3 |
| ALARM 1 |
|
|
| ;VARIABLE DOCUMENTATION |
| ;S0=CLLI A USER INPUT |
| ;S1=CLLI B USER INPUT |
| ;S2=CLLI LOCAL USER INPUT |
| ;S3=YEAR 2 DIGIT USER INPUT |
| ;S4=MONTH 2 DIGIT USER INPUT |
| ;S5=DAY 2 DIGIT USER INPUT |
| ;S6=HOUR 2 DIGIT USER INPUT |
| ;S7=MINUTE 2 DIGIT USER INPUT |
| ;S8=SYSTEM ID & USER RESPONSE USED TO CONTROL PROGRAM FLOW |
| ;S9=SYSTEM NUMBER |
|
|
| LABEL1: |
|
|
| ; note the following statement was superseded in version 4.10 by VPRINT |
| ;DOS "MODE LPT1:=COM2:" ; REQUIRED TO TURN PRINTER ERROR OFF |
| ; following flushes the "RUB" buffer |
| TRANSMIT "^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H" |
| CLEAR |
| LOCATE 10,2 |
| MESSAGE "Enter CLLI code for LOCATION A (C.O.) using full 8 or 11 characters:" |
| LOCATE 12,2 |
| GET S0 11 ;CLLI A |
| MESSAGE " " |
| CLEAR |
| LOCATE 10,2 |
| MESSAGE "Enter CLLI code for LOCATION B (REMOTE) using full 8 or 11 characters:" |
| LOCATE 12,2 |
| GET S1 11 ;CLLI B |
| MESSAGE " " |
| CLEAR |
| LOCATE 10,2 |
| MESSAGE "Enter CLLI code for YOUR location using full 8 or 11 characters:" |
| LOCATE 12,2 |
| GET S2 11 |
|
|
| CLEAR |
| LOCATE 8,2 |
| MESSAGE "Enter system ID without 'MI', for example ALBNMN-JCSNMN." |
| LOCATE 10,2 |
| GET S8 13 |
| LOCATE 13,2 |
| MESSAGE "Enter system number, for example 1201 / T3X." |
| LOCATE 15,2 |
| GET S9 15 |
|
|
| TRANSMIT "CGNS" |
| TRANSMIT "`"" |
| TRANSMIT S8 |
| TRANSMIT "`"" |
| TRANSMIT "!" |
|
|
| CLEAR |
| LOCATE 6,2 |
| MESSAGE "Enter today's date." |
| LOCATE 8,2 |
| MESSAGE "Enter two digit year + <ENTER>" |
| LOCATE 8,34 |
| GET S3 2 ; 2 DIGIT YEAR |
| LOCATE 10,2 |
| MESSAGE "Enter two digit month + <ENTER>. Use 0's if required." |
| LOCATE 10,58 |
| GET S4 2 ; 2 DIGIT MONTH |
| LOCATE 12,2 |
| MESSAGE "Enter two digit day + <ENTER>. Use 0's if required." |
| LOCATE 12,56 |
| GET S5 2 ; 2 DIGIT DAY |
| CLEAR |
| LOCATE 6,2 |
| MESSAGE "Enter time." |
| LOCATE 8,2 |
| MESSAGE "Enter two digit hour + <ENTER>. Use 0's if required." |
| LOCATE 8,57 |
| GET S6 2 ; 2 DIGIT HOUR |
| LOCATE 10,2 |
| MESSAGE "Enter two digit minute + <ENTER>. Use 0's if required." |
| LOCATE 10,59 |
| GET S7 2 ; 2 DIGIT MINUTE |
| CLEAR |
|
|
| ;SET TIME DP3025 |
| TRANSMIT "CT" |
| TRANSMIT S6 |
| TRANSMIT " " |
| TRANSMIT S7 |
| TRANSMIT " !" |
| PAUSE 1 |
| KFLUSH |
| RFLUSH |
| CLEAR |
|
|
| ;PROMPT THE USER TO CHECK INPUTS FOR LOCATIONS |
| LOCATE 1,2 |
| MESSAGE "Please verify the following information." |
| LOCATE 4,2 |
| MESSAGE "LOCATION A CLLI CODE = " |
| LOCATE 4,26 |
| MESSAGE S0 |
| LOCATE 6,2 |
| MESSAGE "LOCATION B CLLI CODE = " |
| LOCATE 6,26 |
| MESSAGE S1 |
| LOCATE 8,2 |
| MESSAGE "LOCAL LOCATION CLLI CODE =" |
| LOCATE 8,29 |
| MESSAGE S2 |
| LOCATE 10,2 |
| MESSAGE "SYSTEM ID = " |
| LOCATE 10,17 |
| MESSAGE S8 |
| LOCATE 12,2 |
| MESSAGE "SYSTEM NUMBER = " |
| LOCATE 12,21 |
| MESSAGE S9 |
| LOCATE 17,2 |
| MESSAGE "IS INFORMATION CORRECT? Y/N + <ENTER>" |
| LOCATE 17,44 |
| GET S8 1 |
| SWITCH S8 |
| CASE "Y" |
| ;DO NOTHING |
| ENDCASE |
| DEFAULT |
| GOTO LABEL1 ; JUMP TO TOP AND ENTER INFORMATION AGAIN |
| ENDCASE |
| ENDSWITCH |
| CLEAR |
| LOCATE 8,15 |
| MESSAGE "DO NOT PRESS ANY KEYS UNTIL CONFIGURATION COMPLETE" |
| LOCATE 10,15 |
| MESSAGE "OK...HERE WE GO..." |
| ALARM 1 |
| PAUSE 2 |
|
|
| ;SET DATE DP3024 |
| TRANSMIT "CD" |
| TRANSMIT S3 |
| TRANSMIT " " |
| TRANSMIT S4 |
| TRANSMIT " " |
| TRANSMIT S5 |
| TRANSMIT " !" |
| PAUSE 1 |
|
|
| ;NAME NODE 1 USING CENTRAL OFFICE CLLI CODE |
| TRANSMIT "CGNN1 " |
| TRANSMIT "`"" |
| TRANSMIT S0 |
| TRANSMIT "`"" |
| TRANSMIT "!" |
|
|
| ;NAME NODE 2 USING REMOTE CLLI CODE |
| TRANSMIT "CGNN2 " |
| TRANSMIT "`"" |
| TRANSMIT S1 |
| TRANSMIT "`"" |
| TRANSMIT "!" |
|
|
| ;DEFINE SITE |
| TRANSMIT "CGS1 1 2 !" |
| ;TRANSMIT "`"" |
| ;TRANSMIT S0 |
| ;TRANSMIT "`"" |
| ;TRANSMIT S1 |
| ;TRANSMIT " " |
| ;TRANSMIT "!" |
|
|
| ;CONFIGURE CUSTOMER OUTPUT POINTS DP3013 |
| TRANSMIT "CGNO1 " |
| TRANSMIT "`"BAY MINOR`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO2 " |
| TRANSMIT "`"BAY MAJOR`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO3 " |
| TRANSMIT "`"OPT A FAIL`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO4 " |
| TRANSMIT "`"OPT B FAIL`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO5 " |
| TRANSMIT "`"STX TX`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO6 " |
| TRANSMIT "`"STX RX`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO7 " |
| TRANSMIT "`"M13 ALARM #1`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO8 " |
| TRANSMIT "`"M13 ALARM #2`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO9 " |
| TRANSMIT "`"M13 ALARM #3`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO10 " |
| TRANSMIT "`"HSA ALARM`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO11 " |
| TRANSMIT "`"HSB ALARM`"" |
| TRANSMIT "!" |
| ;TRANSMIT "CGNO12 " |
| ;TRANSMIT "`"DS1 GRP FAIL`"" |
| ;TRANSMIT "!" |
| TRANSMIT "CGNO13 " |
| TRANSMIT "`"" |
| TRANSMIT S9 |
| TRANSMIT "`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO14 " |
| TRANSMIT "`"COM EQUIP ALRM`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO15 " |
| TRANSMIT "`"NODE #1 CO`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNO16 " |
| TRANSMIT "`"NODE #2 REMOTE`"" |
| TRANSMIT "!" |
|
|
| ;DELETE ALL EXISTING CUSTOMER OUTPUTS |
| TRANSMIT "CGO1 D*!" |
| TRANSMIT "CGO2 D*!" |
| TRANSMIT "CGO3 D*!" |
| TRANSMIT "CGO4 D*!" |
| TRANSMIT "CGO5 D*!" |
| TRANSMIT "CGO6 D*!" |
| TRANSMIT "CGO7 D*!" |
| TRANSMIT "CGO8 D*!" |
| TRANSMIT "CGO9 D*!" |
| TRANSMIT "CGO10 D*!" |
| TRANSMIT "CGO11 D*!" |
| TRANSMIT "CGO12 D*!" |
| TRANSMIT "CGO13 D*!" |
| TRANSMIT "CGO14 D*!" |
| TRANSMIT "CGO15 D*!" |
| TRANSMIT "CGO16 D*!" |
|
|
| ;CUSTOMER OUTPUTS 1-2 |
| TRANSMIT "CGO1 AS1 G100 !" |
| TRANSMIT "CGO2 AS1 G120 !" |
|
|
| ;CUSTOMER OUTPUTS 3-9 |
| TRANSMIT "CGO3 AS1 G107 !" |
| TRANSMIT "CGO4 AS1 G108 !" |
| TRANSMIT "CGO5 AS1 G101 !" |
| TRANSMIT "CGO5 AS1 G102 !" |
| TRANSMIT "CGO5 AS1 G103 !" |
| TRANSMIT "CGO6 AS1 G104 !" |
| TRANSMIT "CGO6 AS1 G105 !" |
| TRANSMIT "CGO6 AS1 G106 !" |
| TRANSMIT "CGO7 AS1 G109 !" |
| TRANSMIT "CGO8 AS1 G110 !" |
| TRANSMIT "CGO9 AS1 G111 !" |
|
|
| ;CUSTOMER OUTPUTS 10-11 |
| TRANSMIT "CGO10 AS1 M1 MH18 !" |
| TRANSMIT "CGO10 AS1 M2 MH18 !" |
| TRANSMIT "CGO10 AS1 M3 MH18 !" |
| TRANSMIT "CGO11 AS1 M1 MH19 !" |
| TRANSMIT "CGO11 AS1 M2 MH19 !" |
| TRANSMIT "CGO11 AS1 M3 MH19 !" |
| ;TRANSMIT "CGO12 AS1 M1 1H2 !" |
| ;TRANSMIT "CGO12 AS1 M2 1H2 !" |
| ;TRANSMIT "CGO12 AS1 M3 1H2 !" |
| ;TRANSMIT "CGO12 AS1 M1 1H3 !" |
| ;TRANSMIT "CGO12 AS1 M2 1H3 !" |
| ;TRANSMIT "CGO12 AS1 M3 1H3 !" |
|
|
| ;CUSTOMER OUTPUT 13, 14 |
| TRANSMIT "CGO13 AS1 G100 !" |
| TRANSMIT "CGO13 AS1 G120 !" |
| TRANSMIT "CGO14 AS1 G112 !" |
|
|
| ;CUSTOMER OUTPUTS 15, 16 |
| TRANSMIT "CGO15 AN1 G100 !" |
| TRANSMIT "CGO15 AN1 G120 !" |
| TRANSMIT "CGO16 AN2 G100 !" |
| TRANSMIT "CGO16 AN2 G120 !" |
|
|
| ;SET TO AUTOMATIC CONTROL |
| TRANSMIT "CGO1 CA!" |
| TRANSMIT "CGO2 CA!" |
| TRANSMIT "CGO3 CA!" |
| TRANSMIT "CGO4 CA!" |
| TRANSMIT "CGO5 CA!" |
| TRANSMIT "CGO6 CA!" |
| TRANSMIT "CGO7 CA!" |
| TRANSMIT "CGO8 CA!" |
| TRANSMIT "CGO9 CA!" |
| TRANSMIT "CGO10 CA!" |
| TRANSMIT "CGO11 CA!" |
| TRANSMIT "CGO12 CA!" |
| TRANSMIT "CGO13 CA!" |
| TRANSMIT "CGO14 CA!" |
| TRANSMIT "CGO15 CA!" |
| TRANSMIT "CGO16 CA!" |
| ; |
| ;DEFINE CUSTOMER OUTPUT 12 |
| TRANSMIT "CGO12 D*!" |
| TRANSMIT "CGNO12 " |
| TRANSMIT "`"EXT ALM`"" |
| TRANSMIT "!" |
| TRANSMIT "CGO12 AN2 G118 !" |
| ;also attach to pt 13 for alarm center ID |
| TRANSMIT "CGO13 AN2 G118 !" |
| ; |
| ;DEFINE CUSTOMER INPUTS |
| TRANSMIT "CGNI1 " |
| TRANSMIT "`"SMOKE DET.`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNI2 " |
| TRANSMIT "`"SUMP PUMP`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNI3 " |
| TRANSMIT "`"OPEN DOOR`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNI4 " |
| TRANSMIT "`"AC PWR FAIL`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNI5 " |
| TRANSMIT "`"HI-LO TEMP`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNI6 " |
| TRANSMIT "`"RECT. FAIL`"" |
| TRANSMIT "!" |
| TRANSMIT "CGNI7 " |
| TRANSMIT "`"BATT FLOAT`"" |
| TRANSMIT "!" |
| ; |
| ;ADD CONDITIONS TO CUSTOMER OUTPUT 1 |
| TRANSMIT "CGO1 AN2 SS5 !" |
| TRANSMIT "CGO1 AN2 SS6 !" |
| TRANSMIT "CGO1 AN2 SS7 !" |
| ; |
| ;ADD CONDITIONS TO CUSTOMER OUTPUT 2 |
| TRANSMIT "CGO2 AN2 SS1 !" |
| TRANSMIT "CGO2 AN2 SS2 !" |
| TRANSMIT "CGO2 AN2 SS3 !" |
| TRANSMIT "CGO2 AN2 SS4 !" |
| ; |
| ;PER JOE OLSZTYN SWITCHING SYSTEMS STAFF |
| ;LEAVE PERFORMANCE MONITORING AT FACTORY DEFAULT |
| ;DISABLE BLUE INSERTION FOR POINT TO POINT SYSTEMS |
| ;IN A MULTIPOINT SYSTEM BLUE INSERTION SHOULD BE ENABLED. |
|
|
| ;ENABLE ALARM LOGGER |
| TRANSMIT "CAD!" |
|
|
| ;DISABLE BLUE INSERTION NODE 1 DP3019 |
| TRANSMIT "CN1 T1 BE!" |
| TRANSMIT "CN1 T2 BE!" |
| TRANSMIT "CN1 T3 BE!" |
|
|
| ;ENABLE PARITY CORRECTION NODE 1 DP3020 |
| TRANSMIT "CN1 T1 PE!" |
| TRANSMIT "CN1 T2 PE!" |
| TRANSMIT "CN1 T3 PE!" |
|
|
| ;ENABLE RX OVERHEAD NODE 1 DP3021 |
| TRANSMIT "CN1 T1 RE!" |
| TRANSMIT "CN1 T2 RE!" |
| TRANSMIT "CN1 T3 RE!" |
|
|
| ;ENABLE TX OVERHEAD NODE 1 DP3022 |
| TRANSMIT "CN1 T1 TE!" |
| TRANSMIT "CN1 T2 TE!" |
| TRANSMIT "CN1 T3 TE!" |
|
|
| ;SIGNAL DEGRADE 10E-8 NODE 1 DP3158 |
| TRANSMIT "CN1 T1 S8!" |
| TRANSMIT "CN1 T2 S8!" |
| TRANSMIT "CN1 T3 S8!" |
|
|
| ;DISABLE BLUE INSERTION NODE 2 DP3019 |
| TRANSMIT "CN2 T1 BE!" |
| TRANSMIT "CN2 T2 BE!" |
| TRANSMIT "CN2 T3 BE!" |
|
|
| ;ENABLE PARITY CORRECTION NODE 2 DP3020 |
| TRANSMIT "CN2 T1 PE!" |
| TRANSMIT "CN2 T2 PE!" |
| TRANSMIT "CN2 T3 PE!" |
|
|
| ;ENABLE RX OVERHEAD NODE 2 DP3021 |
| TRANSMIT "CN2 T1 RE!" |
| TRANSMIT "CN2 T2 RE!" |
| TRANSMIT "CN2 T3 RE!" |
|
|
| ;ENABLE TX OVERHEAD NODE 2 DP3022 |
| TRANSMIT "CN2 T1 TE!" |
| TRANSMIT "CN2 T2 TE!" |
| TRANSMIT "CN2 T3 TE!" |
|
|
| ;SIGNAL DEGRADE 10E-8 NODE 2 DP3158 |
| TRANSMIT "CN2 T1 S8!" |
| TRANSMIT "CN2 T2 S8!" |
| TRANSMIT "CN2 T3 S8!" |
|
|
| ;LINE LEARN ALL MULTIPLEXERS BOTH NODES |
| TRANSMIT "CN1 M1 L!" |
| TRANSMIT "CN1 M2 L!" |
| TRANSMIT "CN1 M3 L!" |
| TRANSMIT "CN2 M1 L!" |
| TRANSMIT "CN2 M2 L!" |
| TRANSMIT "CN2 M3 L!" |
|
|
| ;CONFIGURATION IS COMPLETE EXIT THE PROGRAM |
| CLEAR |
| ALARM 1 |
| LOCATE 10,20 |
| MESSAGE "......CONFIGURATION COMPLETE......" |
| LOCATE 14,17 |
| MESSAGE "CONTINUE WITH SECTION 5 OF CERTIFICATION" |
| ALARM 2 |
| PAUSE 5 |
| EXIT |
|
|
|
|
| ---------------------------------------------------------------------------- |
| Glossary of Terms |
|
|
| 4W Four Wire |
| ACO Alarm Cut-Off |
| ACTV Active (module -- carrying traffic) |
| AGC Automatic Gain Control |
| AIS Alarm Indication Signal -- indicates an alarm upstream |
| AMI Alternate Mark Inversion -- a technique by which the polarity of |
| alternate pulses is inverted |
| APD Avalanche Photo Diode -- used for detecting pulses of light |
| at the receive end of an optical fiber |
| AUD Audible alarm |
| BDF Battery Distribution Frame |
| BER Bit Error Rate |
| BIP Bit Interleave Parity |
| BPV Bipolar Violation -- signal is not alternating as expected |
| CAMMS Centralized Access Maintenance and Monitoring System -- |
| a bay-mounted shelf with push buttons and an luminescent display, |
| which is used to control FMT-150 networks, as well as other |
| Northern Telecom transmission equipment |
| CDP Centralized Display Panel |
| CEV Controlled Environment Vault |
| CO Central Office |
| CPC Common Product Code -- a Northern Telecom code used to identify |
| equipment |
| DDD Direct Distance Dialing |
| DM-13 Digital Multiplexer which multiplexes between DS-1/1C/2 signals |
| and DS-3 signals |
| DNA Dynamic Network Architecture |
| E2A A serial interface for alarm polling of equipment |
| FE Frame Error |
| FER Frame Error Rate |
| FL Frame Loss |
| FLC Frame Loss Counter |
| FLS Frame Loss Seconds |
| FPD Future Product to be Developed |
| Group A multiplexed signal made up of four DS-1s, two DS-1Cs, or |
| one Ds-2 |
| Hub An FMT-150 site which branches one 150 Mb/s signal into two or |
| three signals, in different directions, without sacrificing |
| OA & M continuity |
| LBR Loopback Request |
| MCU Maintenance Control Unit |
| MM Multimode Optical Fiber |
| MSB Most Significant Bit |
| Muldem Multiplexer/demultiplexer |
| NRZ Non-Return to Zero |
| OTT Optical Termination Tray |
| PEC Product Engineering Code -- a Norther Telecom code used to identify |
| equipment. The preferred code to be used when ordering Northern |
| Telecom equipment. |
| PER Parity Error Rate |
| PES Parity Error Seconds |
| RTO Ready To Order |
| SCU Service Channel Unit |
| SMB Sub-Miniature BNC type connector |
| SR Stuff Request |
| STX (Pseudo) Synchronous Transport Signal: First Level at |
| 49.92 Mb/s (Northern Telecom) |
| TBOS Telemetry Byte Oriented System |
| VIS Visual Alarm |
| WDM Wavelength Division Multiplexing |
| XOW Express Orderwire |
|
|
|
|