| ==Phrack Magazine== |
|
|
| Volume Five, Issue Forty-Five, File 21 of 28 |
|
|
| **************************************************************************** |
|
|
| The Universal Data Converter |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| Written by: Maldoror |
| ~~~ChUrcH oF ThE nOnConFOrMisT~~~ |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| -=[ DELAMO LABS INC ]=- |
| """"""""""""""""""""""""""""" |
|
|
| What IS a UDC?! |
| """"""""""""""" |
|
|
| The Universal Data converter (UDC), by Applied Computing Devices, |
| was put into widespread use in 1979. A UDC is used primarily in |
| connection with a variety of switches, to log everything the switch does, |
| and report it to the Central Office in a standard format, allowing the |
| monitoring and reporting of a variety of different switches by one processor |
| without the need of understanding each individual switch. This lets the |
| Telco-Trouble shooters monitor exactly how much traffic is passing |
| thru a given switch. Exact number of calls, busys & fraud attempts, are |
| some examples. A UDC will give detailed reports of such activity, as |
| well as hold it in a buffer file which you can view for your own excitement. |
| The real purpose of this piece of hardware is to buffer data, convert it |
| to a standard format, and send it on it's merry way to the Central Processor. |
| Information may be buffered for up to an hour, before being able to be |
| received by the Central Processor. |
|
|
| Which Switches use a UDC? |
| """"""""""""""""""""""""" |
|
|
| Well, apparently, nearly all switches owned by a tel-co use a UDC |
| for their daily reports. Here is a list of the switches of which I know |
| may be connected to a converter: |
|
|
|
|
| At&t Autoplex 100 |
| ITT/North 1210 |
| ITT/North NX-1E |
| ITT/North "1200" Series (DSS-1) |
| GTE GTD-1 (Automatic Electric no. 1 EAX) |
| GTE GTD-2 (Automatic Electric no. 2 EAX) |
| GTE GTD-3 (Automatic Electric no. 3 EAX) |
| GTE GTD-5 |
| Motorola EMX-250 |
| NEC NEAX-61 |
| NEC ND-20S |
| Northern Telecom DMS-10 |
| Northern Telecom DMS-100 |
| Northern Telecom DMS-200 |
| Northern Telecom DMS-250 |
| Northern Telecom DMS-300 |
| Northern Telecom SL-1 (Seen these around locally) |
| Northern Telecom SP-1 PABX |
| Stromberg Carlson DCO |
| TRW Vidar ITS-4 |
| TRW Vidar ITS-4/5 |
| TRW Vidar ITS-5 |
| Western Electric 5 ESS |
| GTE PBX's (GTD-1000, GTD-4600) |
|
|
|
|
|
|
| General Configurations: |
| """"""""""""""""""""""" |
|
|
| A UDC may be configured in several ways. A UDC consists of up to 6 ports. |
| Port 0 is usually a dialin line, in which it is connected to a 300/1200 |
| baud modem, so that GTE employees may call to check their switch |
| information in the field. |
|
|
| Port 0 may also be a dedicated line, which is linked to a computer somewhere |
| important, but if this is the case, you can't have found it anyways, so don't |
| worry about it. (Unless of course you another indial port possibly 1) |
|
|
| Port 2 is usually the line which is hardwired to the data output of the |
| switch. This port receives the messages of a switch, analyses the data, |
| buffers it, and waits until it is told to send the data to the CP, which |
| may be every time the buffer flips, which of course is configured by hardware. |
| It is not required that port 2 be the hardwire, although it is just the |
| most common configuration. |
|
|
| Port 1 & 3-7 are also multi-use ports , which may be configured |
| either for a dedicated line, or a standard phone line, just like port 1. |
| The difference between this port and port 0 however, is that this port may |
| also be used to test lines other than the hardware set report line #. |
| (More later.) |
|
|
| NOTE: ANY of these ports can be completely different depending on the |
| setup of the UDC's cards, and which slot they are in... |
|
|
|
|
| The UDC can be configured (though I have never seen it this way) so that any |
| of the six ports can preform the functions instead of the first three. |
| If you find a UDC, be sure to check all the ports, and not just three. |
|
|
| The general idea of this box of tin is that it will monitor any |
| switch, collect data into a buffer, and store it until it need be |
| converted and polled by the SAC. When the data is sent out, it is sent |
| in standard UDC format, regardless of the type of switch, therefore any |
| switch may be monitored by the SAC without having to be converted on |
| the spot. |
|
|
| Yeah Great what the ?#!$ do I do? |
| """"""""""""""""""""""""""""""""' |
|
|
| Scan your local area for all numbers ending in 99xx or 00xx, often |
| (with GTE anyways) the prefix may be something like 446-9988, or something |
| outright obvious. Once you find one, you will know, because you will |
| get one of two things. Depending on the configuration of the UDC, |
| you will either begin getting a dump of data, which will go into detail |
| about the switch information, or you will get a prompt: |
|
|
| *B*> |
|
|
| When you receive this prompt, you can make your life easy by typing |
| HELP in all caps, for a menu of commands, which will seem important at |
| first (don't fool yourself). |
|
|
| Each letter between *'s represents a separate processor (yes even this tin |
| box has more than one! These letters will be in the menu |
| when you type HELP. To change processors, you will need to hold control |
| while pressing the letter of the processor you wish to change to. |
|
|
| Here is a list of commands for each processor: |
|
|
| The Basic processor |
| ~~~~~~~~~~~~~~~~~~~ |
|
|
| *B*> DATE Display the system Date |
|
|
| *B*> DATE mm/dd/yy Set the date to mm/dd/yy |
|
|
| *B*> DIAGNOSTIC This puts you in debug mode for the UDC's program |
| When typing this command the UDC will respond with |
| "PASSWORD" and will not echo letters. If the password |
| given is correct, you will get a prompt like this: |
| *B*> DIAG |
| PASSWORD 305 > I enter the good password< |
| DEBUG 1,3 > 1,3 are the ports in use < |
| ? |
| At this point you can reboot the UDC by typing: |
| ? G |
| (ADDR)=1000 > I tell it to jmp to 1000 < |
| Then all hell will break loose...trust me! |
| O.k. well it will look like it anyway... |
|
|
|
|
| *B*> HELP Duh um, a Menu |
|
|
| *B*> RAMPAGE Test traffic data storage area |
|
|
| *B*> SYSTEM Display system checksums |
|
|
| *B*> TIME Display system time |
|
|
| *B*> TIME hh:mm:ss Set system time (confuse them, set it back then forwd) |
|
|
|
|
| The Patch Processor |
| ~~~~~~~~~~~~~~~~~~~ |
|
|
| *P*> ANSWER n Take channel 'n' off hook (neato) |
|
|
| *P*> BAUD c,bbbb,nnn Set Channel 'c' Baud rate to 'bbbb', and |
| number of nulls to 'nnn' |
| *P*> HANGUP n Put channel 'n' on hook (log out too) |
|
|
| *P*> HELP Help Menus |
|
|
| *P*> PATCH n Patch calling port to port 'n' (Dial out!) |
| It IS possible to patch to modem ports, but I don't |
| recommend it...all GTE numbers have their own COS. |
| (Easy to find you) |
|
|
| The Plant Queue Processor |
| ~~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| *Q*> ALARM Display the alarm (error message) string |
|
|
| *Q*> ALARM xx..xxx Set Alarm String (change it back if u want) |
|
|
| *Q*> CLEAR Clear buffer without printing contents (not preferred) |
|
|
| *Q*> DUMP Print and clear contents (destructive, not preferred) |
|
|
| *Q*> HELP Help Menu |
|
|
| *Q*> LIMITS Display buffer alarm threshold |
|
|
| *Q*> LIMITS nnnnn Set buffer alarm threshold to 'nnnn' |
|
|
| *Q*> LIST Display buffer contents (Better than dump)(ok!) |
|
|
| *Q*> LIST nnnn Display buffer contents from 'nnnn' to end |
|
|
|
|
| The Report Processor |
| ~~~~~~~~~~~~~~~~~~~~ |
|
|
| *R*> BACKUP Transfer a copy of the ROM based table to the |
| editor workspace |
| *R*> DEFAULT Make the ROM based table effective (can crash) |
|
|
| *R*> EDIT Engage in edit mode |
|
|
| APPEND Add line to RMT (Hi there Gen-Tel!) |
| DELETE Delete line from RMT |
| END End edit session |
| HELP List Editor Commands |
| LIST List RMT |
| MODIFY Modify a line in RMT |
|
|
| *R*> DOWNLOAD Download RMT to PROM programmer (ha!) |
|
|
| *R*> HELP More menus |
|
|
| *R*> LIST List effective RMT |
|
|
| *R*> LIST N List RMT without Heading |
|
|
| *R*> LIST nnnn List line 'nnnn' of effective RMT |
|
|
| *R*> LIST nnnnN List line 'nnnn' of effective RMT without heading |
|
|
| *R*> LIST nnnn,mmmm List lines 'nnnn' to 'mmmm' of RMT |
|
|
| *R*> LIST nnnn,mmmmN List lines 'nnnn' to 'mmmm' of RMT without heaading |
|
|
| *R*> NEW Clear the editor workspace |
|
|
| *R*> USER Make RAM based RMT active |
|
|
|
|
| The Scanner Processor |
| ~~~~~~~~~~~~~~~~~~~~~ |
|
|
| *S*> CIRCUIT Display Status Report |
|
|
| *S*> CIRCUIT nnn OFF Turn off circuit 'nnn' and print Status report |
|
|
| *S*> CIRCUIT nnn OFF N Turn off circuit 'nnn' without report |
|
|
| *S*> CIRCUIT nnn,mmm OFF Turn off circuts 'nnn' to 'mmm' |
|
|
| *S*> CIRCUIT nnn,mmm OFF N Turn off 'nnn' to 'mmm' without report |
|
|
| *S*> CIRCUIT nnn ON Turn 'nnn' ON and print report |
|
|
| *S*> CIRCUIT nnn ON N Turn 'nnn' ON without report |
|
|
| *S*> CIRCUIT nnn,mmm ON Turn circuts 'nnn' to 'mmm' on and print status report |
|
|
| *S*> CIRCUIT nnn,mmm,ON N Turn on 'nnn' to 'mmm' but do not print report |
|
|
| *S*> REPORT Display names of disable reports |
|
|
| *S*> REPORT report.type OFF Disable 'report.type' for printing |
|
|
| *S*> REPORT report.type ON Enable 'report.type' for printing |
|
|
| *S*> RESTART Restart scanner interrogation |
|
|
| *S*> ROUTE n Display all future alarm reports on channel 'n' |
|
|
| *S*> STOP Stop scanner interrogation |
|
|
| *S*> TEST Dial the alarm number set on the system optioning |
| board (dip switches on the config board) for |
| communication line testing. |
|
|
| *S*> TEST 3,1 nnn nnn nnnn Dial the indicated number (on port 3) and test |
| the communication lines. |
| If you test with the port you called in on, |
| you will have to hangup and call back for the |
| results. (Port 0) |
|
|
| The Traffic Processor |
| ~~~~~~~~~~~~~~~~~~~~~ |
|
|
| *T*> ACTIVE Display the contents of the active buffer |
|
|
| *T*> BANK Display bank to be polled |
|
|
| *T*> BANK n Set Bank to be polled (bank 'n') |
|
|
| *T*> FLIP Flip the buffers (this MAY cause polling, depending |
| on the hardware (switch) & port configuration) |
| *T*> HELP Processor Menus |
|
|
| *T*> METERS Display current meter limits |
|
|
| *T*> METERS nnnn Set upper meter limits |
|
|
| *T*> METERS mmmm,nnnn Set lower and upper meter limits |
|
|
| *T*> METERS mmmm,nnnn V Set variable meter limits |
|
|
| *T*> METERS mmmm,nnnn F Set fixed meter limits |
|
|
| *T*> PASSIVE Display the contents of a Passive buffer |
|
|
| *T*> TRAFFIC Interrupt or resume traffic after user interaction |
| with channel 1 |
|
|
|
|
|
|
| Standard Control Codes |
| ~~~~~~~~~~~~~~~~~~~~~ |
|
|
| ^A Start of Heading |
| ^B Start of Text |
| ^C End of Text |
| ^D End of transmission |
| ^E Enquiry (no not like CBI) |
| ^F Acknowledgment |
| ^G Bell :) |
| ^H Backspace |
| ^I Horizontal Tab |
| ^J Line feed |
| ^K Vertical Tab |
| ^L Form Feed |
| ^M Carriage return |
| ^N Shift out |
| ^O Shift in |
| ^P Data line escape |
| ^Q Device Control 1 |
| ^R Device Control 2 |
| ^S Device Control 3 |
| ^T Device Control 4 |
| ^U Negative Acknowledgment |
| ^V Synchronous Idle |
| ^W End of Transmission Block |
| ^X Cancel |
| ^Y End of Medium |
| ^Z Substitute |
|
|
|
|
|
|
| What is all this? |
| ~~~~~~~~~~~~~~~~ |
|
|
| The RMT data is the data transmitted to the UDC by the switch. This data |
| is formatted in such a way that it tells the UDC what is happening and what |
| has already happened since the last buffer flip. This data is then converted |
| to a standard format to be transferred to the Central Processor. For examples |
| of switch output, refer to the switch example list further in this article. |
|
|
| Here is an example of the System Output data, after being translated into |
| standard format by the UDC: |
|
|
|
|
| The first two lines of the System Output data will contain the values |
| of the 19 status registers as follows: |
|
|
| 0 1 2 3 4 5 6 7 8 9 |
|
|
| 000 00345 00003 00013 00000 00005 00000 00005 01903 00012 00000 |
| 001 06800 01021 01101 01065 00000 00003 00007 02435 00000 00000 |
|
|
| 10 11 12 13 14 15 16 17 18 19 |
|
|
| The registers are as follows: |
|
|
| 0 UDC control program number (usually 345, newer versions may be diff.) |
| 1 UDC control program version (1,3,5,etc.) |
| 2 Hour at buffer flip (active to passive) |
| 3 Minute at buffer flip (active to passive) |
| 4 Number of buffer flips since power on (65535 maximum) |
| 5 Power interrupt flag (99 if fewer than two intervals have occurred |
| since the power interrupt or hard restart; 0 otherwise) |
| 6 Number of reports in the buffer |
| 7 Total number of meters in this buffer (including headers) |
| 8 Hour at buffer flip (passive to active) |
| 9 Minute at buffer flip (passive to active) |
| 10-13 Strapping Card signature |
| 14 Total number of errors since last had reset or power up |
| 15 Number of soft restarts since last power-up or hard restart |
| 16 Number of buffer flips since last soft restart |
| 17 Address of last error which caused a soft restart |
| 18-19 unused |
|
|
|
|
| When a traffic report is to be sent, the following header will be sent |
| (in the System Output) to the UDC processor(s) to tell the traffic processor |
| to begin buffering the report: |
|
|
| 0 1 2 3 4 5 6 7 8 9 |
|
|
| 190 65535 00008 00022 00000 00000 00000 00000 00000 00000 00000 |
| 191 00004 00027 00078 00700 00800 31227 00074 00000 00002 00018 |
| 192 00078 00000 00000 00000 00000 00000 00000 00000 00000 00000 |
|
|
| 10 11 12 13 14 15 16 17 18 19 |
|
|
| The registers for the header are as follows: |
|
|
| 0 65535 (This signals the beginning of the switch report) |
| 1 Message type obtained from the 'type' field of the RMT |
| 2 The number of registers used by the message, including the |
| 10 registers of this header. |
| 3-9 unused (00000) |
|
|
|
|
|
|
| Ok ?! Now what?! |
| ~~~~~~~~~~~~~~~~~ |
|
|
| Well now that I have explained all the commands, the data formats, etc, |
| of the UDC, you can now check the RMT or TRAFFIC buffers to see exactly |
| what type of switch you are monitoring. Here are some examples of the |
| Data format for the following switches: |
|
|
| ************************************************************************ |
| ------------------- AT&T AUTOPLEX 100 SWITCH ------------------------- |
| ************************************************************************ |
|
|
|
|
| Example of RMT data: |
| ~~~~~~~~~~~~~~~~~~~ |
|
|
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| ------------------------------------------------------------------------------ |
| 001 000 /M 00/ 001 075 255 65535 65535 |
| 002 001 /BLOCK C/ 002 077 001 00020 00169 |
| 003 002 /FINISH/ 001 073 255 65535 65535 |
| 004 001 /CELL 001/ 001 077 002 00170 00229 |
| 005 001 /CELL 002/ 001 077 003 00230 00289 |
| 006 001 /CELL 003/ 001 077 004 00290 00349 |
| 007 001 /CELL 005/ 001 077 005 00350 00409 |
| 008 001 /CELL 006/ 001 077 006 00410 00469 |
| 009 001 /CELL 007/ 001 077 007 00470 00529 |
| 010 001 /CELL 008/ 001 077 008 00530 00589 |
| 011 001 /CELL 009/ 001 077 009 00590 00649 |
| 012 001 /CELL 010/ 001 077 010 00650 00709 |
| 013 001 /CELL 011/ 001 077 011 00710 00769 |
| 014 001 /CELL 012/ 001 077 012 00770 00829 |
| 015 001 /CELL 013/ 001 077 013 00830 00889 |
| 016 001 /BLOCK H/ 001 077 014 00890 00949 |
| 017 001 /FINISH/ 001 073 255 65535 65535 |
|
|
|
|
| Example of TRAFFIC report: |
| ~~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| M 00 3/7/1993 THU 13:00:00 |
| #068 |
|
|
| A 30 |
|
|
| BLOCK C 000034 13:00 3/7/1993 12:00 3/7/1993 |
|
|
| (0) |
| 000100 000313 000197 000049 000029 000103 000226 000125 000220 000066 |
| (1) |
| 000180 000291 000238 000123 000050 000154 000326 000146 000074 000089 |
| (2) |
| 000000 000007 000000 000000 000000 000000 000000 000000 000000 000000 |
| (3) |
| 000000 000000 000000 000000 000000 000000 000000 000036 000180 000000 |
| (4) |
| 000023 000023 000366 000000 000000 000000 000000 000000 000000 000000 |
| (5) |
| . |
| . |
| . |
| (more data) |
|
|
| . |
| . |
| (13) |
| 000000 000000 000000 000000 000000 000000 000000 000000 000000 000000 |
| FINISH |
| 03/07/93 13:30:38 |
| #371 |
| . |
| . |
| . |
|
|
| M 00 3/7/1993 THU 13:00:00 |
| #068 |
|
|
|
|
| 00 REPT:AMPSTRSF CELL 001 START 120 STOP 130 03/07 COMPLETE |
| 000089 000014 000000 000000 000000 000000 000084 000014 000201 000001 |
| 000052 000050 000048 000036 000002 000008 000003 000199 000000 002654 |
| 000000 000031 000000 000360 000000 000000 000000 000036 003728 005170 |
| 000000 004065 003170 000000 003992 000071 000000 000067 000146 000000 |
| 000241 000000 000000 000000 000000 000000 000000 000000 000000 000000 |
| #077 |
|
|
| M 00 REPT:RC CENSUS |
| OFFICE RC CHANNEL = REM |
| TRCA OVER 0% FULL |
| RBA OVER 5% FULL |
| RCMDS MODE = 0 |
| #082 |
|
|
|
|
| M 00 REPT:RC SOURCE |
|
|
| SCV=0 |
| CFV=0 |
| RCS=0 |
| DLY=0 |
| VSS=0 |
| ACS=0 |
| CSR=0 |
| BIS=0 |
| TRB=0 |
| FBP=0 |
| LOG=0 |
| CR6=0 |
| #083 |
| . |
| . |
| . |
| (more) |
| . |
| . |
|
|
| ************************************************************************* |
| --------------------- ITT/North 1210 Switch -------------------------- |
| ************************************************************************* |
|
|
|
|
|
|
| Example of RMT data: |
| ~~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 003 FIXED LOWER: 00000 UPPER: 02039 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| ------------------------------------------------------------------------------- |
| 001 000 /:/ 001 076 255 65535 65535 |
| 002 001 /TYPE/ 002 073 255 65535 65535 |
| 003 002 /2 / 003 077 002 00020 00098 |
| 004 002 /4 / 003 077 004 00100 00319 |
| 005 002 /5 / 003 077 005 00320 00469 |
| 006 002 /16 / 003 077 016 00670 01769 |
| 007 002 /18 / 003 077 018 01770 02040 |
| 008 002 /20 / 003 077 020 00470 00669 |
| 009 003 /END/ 000 073 255 65535 65535 |
|
|
| Example of a TRAFFIC report: |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| DSS-1 VAR-00 VER-00 PAT=43 ACD |
| 938 R TRAFF 4703 12/06/93 09:00:00 SBG-B |
| DATA FROM 1210 SWITCH TO UDC |
|
|
| DIAL TONE DELAY |
| TYPE CODE SCAN(SEC) BRP START/TIME LENGTH(MIN) ORDER/DATE |
| 2 R 10 21(45) 08:00 60 12/16/93 |
|
|
| THRESHOLD TIME 2.0 |
|
|
| LSID DTD TIME(SEC) CALLS DELAY CALLS |
| 1 .34 60 1 |
| 2 .47 34 0 |
| SYS TOTAL .43 94 1 |
| END |
|
|
| 936 TRAFF 4703 12/06/93 09:45:55 SBG-B |
| SEPERATIONS |
|
|
| TYPE CODE SCAN(SEC) BRP START/TIME LENGTH(MIN) ORDER/DATE |
| 4 R NONE 10(43Z 12:00 60 12/06/79 |
|
|
| CNTR* VALUE CNTR* VALUE CNTR* VALUE CNTR* VALUE CNTR* VALUE |
| 1 32 2 65 3 73 4 84 5 64 |
| 6 42 7 84 8 51 9 63 10 69 |
|
|
| END |
|
|
| 9344 TRAFF 4703 12/06/93 09:46:00 CALL COUNT |
| . |
| . |
| (more) |
| . |
| . |
|
|
| note: This thing is a beast! If you find one of these call |
| a museum quick!!! |
|
|
| ************************************************************************* |
| --------------- ITT/North NX-1E Switch ----------------------- |
| ************************************************************************* |
|
|
|
|
|
|
| RMT data example: |
| """""""""""""""""" |
|
|
|
|
|
|
| ACTION IN LINE 000 VARIABLE LOWER: 00000 UPPER: 00019 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| --------------------------------------------------------------------------- |
|
|
| 001 000 /:/ 001 076 255 65535 65535 |
| 002 001 /DATA TYPE/ 001 078 001 65535 65535 |
| 003 001 /END OF/ 000 073 255 65535 65535 |
|
|
|
|
| Example of a TRAFFIC report: |
| """""""""""""""""""""""""""" |
|
|
| 26 JUNE 86 10:00:00 THT 735 TM GROUPED DATA DUMP REPORT |
|
|
| TIME OF LAST REPORT: 26 JUNE 78 09:00:00 |
|
|
| DATA TYPE GROUPED DATA |
|
|
| SOTU 572 681 |
|
|
| SOTP 434 863 |
|
|
| RSOU 894 |
|
|
| RSOP 978 |
|
|
| GTCA 1 1 2 3 4 5 6 |
|
|
| SLA 0 0 0 0 1 1 1 |
|
|
| TKTU 631 408 17 358 951 426 324 |
| 436 384 277 462 46 853 956 |
|
|
| TKTP 543 753 783 34 572 294 815 |
| 426 85 357 392 739 212 142 |
|
|
| TK2U 584 282 53 19 |
|
|
| BSWU 27 7 |
|
|
| QTCU 18 |
|
|
| END OF GROUPED DATA DUMP |
|
|
|
|
|
|
| *************************************************************************** |
| ----------- THE GTE GTD-1 (Automatic Electric No.1 EAX) Switch------------- |
| *************************************************************************** |
|
|
| Example of RMT data: |
| ~~~~~~~~~~~~~~~~~~~ |
|
|
|
|
|
|
|
|
| ACTION IN LINE 007 VARIABLE LOWER: 00000 UPPER: 00079 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| --------------------------------------------------------------------------- |
|
|
| 001 000 /HO UR/ 000 075 255 65535 65535 |
| 002 000 /MS 19/ 001 077 001 00020 00039 |
| 003 001 /MS 19/ 001 081 001 00101 65535 |
| 004 001 /COUNTS/ 001 073 255 65535 65535 |
| 005 001 /MS 21/ 002 077 002 00040 00079 |
| 006 002 /MS 21/ 002 081 001 00101 65535 |
| 007 002 /COUNTS/ 003 073 255 65535 65535 |
|
|
|
|
|
|
|
|
|
|
| Example of TRAFFIC report: |
| ~~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| I 00 HO UR 1:00:00 |
| R 00 ME RR 9 |
| R 00 MS 19 7 COUNTS GREATER THAN 0 |
| R 00 MS 19 1,01 1152 1,02 1350 1,03 1194 |
| R 00 MS 19 1,04 1378 1,05 1212 1,06 1231 |
| R 00 MS 19 1,07 1099 |
| R 00 MS 21 7 COUNTS GREATER THAN 0 |
| R 00 MS 21 1,01 397 1,02 570 1,03 574 |
| R 00 MS 21 1,04 542 1,05 682 1,06 668 |
| R 00 MS 21 1,07 542 |
| R 00 MS 22 7 COUNTS GREATER THAN 0 |
|
|
|
|
| ************************************************************************** |
| --------- THE GTE GTD-2 (Automatic Electric No.2 EAX) Switch ------------- |
| ************************************************************************** |
|
|
| Example of RMT data: |
| ~~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 007 VARIABLE LOWER: 00000 UPPER: 00079 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| --------------------------------------------------------------------------- |
| 001 000 /S@/ 001 084 255 65535 65535 |
| 002 001 /MPTK/ 001 078 001 65535 65535 |
| 003 001 /MPSW/ 001 078 002 65535 65535 |
| 004 001 /MPLB/ 001 078 003 65535 65535 |
| 005 001 /MPMA/ 001 078 004 65535 65535 |
| 006 001 /MPLS/ 001 078 005 65535 65535 |
| 007 001 /MPSP/ 001 078 006 65535 65535 |
|
|
|
|
| Example of TRAFFIC report: |
| ~~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| S@1900 TDA MPTK 08-14-86 1900 2000 |
|
|
| TRK ICT ICT ICT OGT OGT OGT PRE |
| GRP USAGE ATT HITS USAGE ATT OFL DIAL |
|
|
| 128 0 0 0 31 18 0 0 |
| 129 0 0 0 32 12 0 0 |
| 130 0 0 0 0 0 0 0 |
| 131 0 0 0 486 269 0 0 |
| 132 0 0 0 55 13 0 0 |
| 133 317 143 0 264 108 0 0 |
| 134 0 0 0 1 2 0 0 |
|
|
| S@1901 TDA PMSW 08-14-86 1900 2000 |
|
|
| SVC USAGE ATT OFL |
|
|
| 10 3 |
| 10 3 164 0 |
| 11 17 163 0 |
| 14 302 2523 0 |
| 15 200 2391 0 |
| 16 377 2187 0 |
| 18 84 1171 0 |
| 19 113 1477 0 |
|
|
|
|
| ************************************************************************** |
| ------------------- The Motorola EMX-250 Switch -------------------------- |
| ************************************************************************** |
|
|
|
|
| Example of RMT data: |
| ~~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPER: 00389 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| ---------------------------------------------------------------------------- |
| 001 000 /TRA21/ 001 078 001 65535 65535 |
| 002 001 / / 002 073 255 65535 65535 |
| 003 002 /^M/ 000 078 002 65535 65535 |
|
|
|
|
|
|
| Example of TRAFFIC report: |
| ~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| TRA21 0307 1400 1500 |
| 0369 0000 00 |
| 00129 00045 00178 00127 00000 00000 00000 00000 |
| 00000 00000 00000 00001 00000 00000 00000 00000 |
| 101 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1 |
|
|
| TRA30 0307 1400 1500 |
| 0000 0000 00 |
| 00000 00000 00000 00000 00000 00000 00000 00000 |
| 00000 00000 00000 00000 00000 00000 00000 00000 |
| 247 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 2134 1 |
|
|
| TRA31 0307 1400 1500 |
| 0000 0000 00 |
| 00000 00000 00000 00000 00000 00000 00000 00000 |
| 00000 00000 00000 00000 00000 00000 00000 00000 |
| 253 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1 |
|
|
| TRA32 0307 1400 1500 |
| 00000 00000 00000 00000 00000 00000 00000 00000 |
| 00000 00000 00000 00000 00000 00000 00000 00000 |
| 254 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1 |
|
|
|
|
| ************************************************************************ |
| ----------------- NEC ND-20S SWITCH ----------------------- |
| ************************************************************************ |
|
|
|
|
| Example of RMT data |
| """"""""""""""""""" |
|
|
|
|
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| -------------------------------------------------------------------------- |
|
|
| 001 000 /// 000 075 255 65535 65535 |
| 002 000 /ORG. CALL/ 001 078 001 65535 65535 |
| 003 001 /DUMP END/ 000 073 255 65535 65535 |
| 004 000 /SPECIAL DU/ 001 078 002 65536 65535 |
|
|
|
|
| Example of TRAFFIC report |
| ~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
|
|
| 06/21 20:01 CON-TEST NG |
| PL:1 0 5 4 5 4 6 PT:1 0 3 1 6 4 2 |
| 06/21 20:02 * TRAFFIC NORMAL DUMP * |
|
|
| COM ORG. CALL ATTEMPTS (PEG COUNT) |
|
|
| 026613 000079 000233 00000 00000 00000 00038 |
| 000000 000114 |
|
|
| COM ORG. CALL COMPLETED (PEG COUNT) |
|
|
| 012172 000049 000113 000047 |
|
|
| OOH TER. CALL COMPLETED (PEG COUNT) |
|
|
| 034146 000142 000000 |
|
|
| OOH CALLED PARTY BUSY ENCOUNTERED (PEG COUNT) |
|
|
| 003356 |
|
|
| 06/21 20:04 *NORMAL DUMP END* |
|
|
|
|
| 000000 000000 |
|
|
| 00H CALLED OFFICE (PEG COUNT) |
|
|
| 000000 000000 000000 000000 000000 000000 000000 000000 |
|
|
| OOH A-LINK USAGE PER NW BASIS (CCS) |
|
|
|
|
| 0733.80 0594.40 0000.00 0000.00 |
|
|
| OOH TRUNK USAGE (CCS) OGY |
|
|
| 0002.40 0004.20 0009.00 0001.60 0009.60 0002.20 0016.00 |
| 0000.00 0003.00 0000.00 0000.00 0046.80 0000.00 0003.00 |
|
|
| 06/21 20:22 *SPECIAL DUMP END* |
|
|
| 06/21 20:22 |
|
|
|
|
| *************************************************************************** |
| ------------------ Northern Telecom DMS-10 Switch ------------------------- |
| *************************************************************************** |
|
|
| Example of RMT data: |
| ~~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 011 VARIABLE LOWER: 00000 UPPER: 00560 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| -------------------------------------------------------------------------- |
| 001 000 /OPM001/ 000 072 001 65535 65535 |
| 002 000 /OPM002/ 000 078 002 65535 65535 |
| 003 000 /OPM003/ 000 078 003 65535 65535 |
| 004 000 /OPM004/ 000 078 004 65535 65535 |
| 005 000 /OPM005/ 000 078 005 65535 65535 |
| 006 000 /OPM006/ 000 078 006 65535 65535 |
| 007 000 /OPM007/ 000 078 007 65535 65535 |
| 008 000 /OPM008/ 000 078 008 65535 65535 |
| 009 000 /OPM009/ 000 078 009 65535 65535 |
| 010 000 /OPM010/ 000 078 010 65535 65535 |
| 011 000 /OPM011/ 000 078 011 65535 65535 |
| 012 000 /OPM012/ 000 078 012 65535 65535 |
| 013 000 /OPM013/ 000 078 013 65535 65535 |
|
|
|
|
| Example of TRAFFIC report |
| ~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| OPM001 TRAF HLST MON 08/19/86 15:00:00 HRHR |
|
|
| PEG BLK USE |
| ORTM 00635 00000 00978 |
| OROG 00477 00000 00685 |
| ORNC 00089 |
| RVRT 00012 |
| INTM 00429 00000 00707 |
| INOG 00000 00000 00000 |
| INNC 00003 |
|
|
| OPM002 OSVC HLST MON 11/02/85 15:00:00 HRHR |
|
|
| PEG |
|
|
| PSIG 00027 |
| PDTO 00015 |
| PABN 00092 |
| FSTR 00168 |
| DGTC 00599 |
| DPC 00874 |
| TOTC 01473 |
| % |
| DGTS 000.0 |
| DPS 000.0 |
| TOTS 000.0 |
|
|
|
|
| ************************************************************************ |
| ----------------- Northern Telecom DMS-100 Switch ---------------------- |
| ************************************************************************ |
|
|
| Example of RMT data |
| ~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 004 VARIABLE LOWER: 00000 UPPER: 01015 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| --------------------------------------------------------------------------- |
| 001 000 /QWMPR2/ 001 075 255 65535 65535 |
| 002 001 /SLOWS/ 002 077 001 00020 00999 |
| 003 002 /TRMT2/ 003 068 066 65535 65535 |
| 004 002 /ANN^J/ 002 068 119 65535 65535 |
| 005 002 /SITE^J/ 003 073 255 65535 65535 |
| 006 003 /TRK^J/ 004 077 002 01000 04499 |
| 007 004 /KEY/ 005 081 019 00027 65535 |
| 008 005 /QFZ^J/ 000 077 003 04500 04920 |
|
|
|
|
| Example of TRAFFIC report |
| ~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| CMFLINT OMPR213 AUG13 15:01:09 3684 INFO CM REPORT |
|
|
| CLASS: NMCTRAFF |
| START: 1986/08/13 14:00:00 WED; STOP: 1986/08/13 15:00:00 WED; |
| SLOWSAMPLES: 36; FASTSAMPLES: 360; |
|
|
| CPU |
| MTCHINT TRAPINT CPUFLT SYSWINIT SYSCINIT SYNCLOSS |
| MSYLOSSU SSYLOSSU |
| 0 0 0 0 0 0 0 |
| 0 0 |
|
|
| ICO |
|
|
| IOCERR IOCLKERR IOCFLT IOCLKSBU IOLKMBU IOCSBU |
| IOCMBU |
| 0 0 0 0 0 0 0 |
| 0 |
|
|
| CMC |
| KEY (CMC_INDEX) |
| . |
| . |
| . |
|
|
| *********************************************************************** |
| ----------------- Northern Telecom DMS-250 ---------------------------- |
| *********************************************************************** |
|
|
| Example of RMT data |
| ~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPER: 02387 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| -------------------------------------------------------------------------- |
| 001 000 /QMPR2/ 001 072 255 65535 65535 |
| 002 001 /INFO/ 002 073 255 65535 65535 |
| 003 002 /SLOWS/ 000 078 001 65535 65535 |
|
|
|
|
|
|
| Example of TRAFFIC data |
| ~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| QMPR18 AUG28 17:00:43 4000 INFO QM REPORT |
| CLASS:SCHOURDC |
| START:1984/08/28 16:00:00 TUE; STOP: 1984/08/28 17:00:00 TUE; |
| SLOWSAMPLES: 36; FASTSAMPLES |
|
|
| TRMT1 |
| VACT UNCA HNPI UNDN BLDN UNIN |
| TESS |
|
|
| 0 60 0 0 0 0 0 |
| 0 0 0 |
|
|
| TRMT2 |
|
|
| DNTR CNOT DCFC PRSC GNCT ATBS |
| MHLD |
|
|
| 0 0 0 0 0 0 0 |
| 0 0 |
|
|
|
|
| QMPR220 AUG28 17:30:16 6100 INFO REPORT |
| CLASS: ADHOURC |
| START:1984/08/28 17:00:00 TUE; STOP 1984/08/28 18:00:00 TUE; |
| SLOWSAMPLES: 36; FASTSAMPLES: 360; |
|
|
| TRK |
| KEY (COMMON_LANGUAGE_NAME) |
| INFO (QM2TRKINFO) |
| INCATOT PRERTEAB INFAIL NATMPT MOVFLATB GLARE |
| QUTFAIL DEFLCDA DREU PREU TRU SBU |
| ANSWER INVAUTH CONNECT TANDEM AQF ANF |
|
|
|
|
| ********************************************************************* |
| ---------------- Northern Telecom SL-1 Switch ---------------------- |
| ********************************************************************* |
|
|
| Example of RMT data |
| ~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 005 (RAM) VARIABLE LOWER: 00000 UPPER: 00010 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| ------------------------------------------------------------------------- |
| 001 000 /TFS000/ 001 073 255 65535 65535 |
| 002 001 /19/ 002 073 255 65535 65535 |
| 003 002 / / 000 084 255 65535 65535 |
| 004 001 /TF/ 000 073 255 65535 65535 |
| 005 002 /TF/ 000 073 255 65535 65535 |
| 006 000 /TFS001/ 000 078 001 65535 65535 |
| 007 000 /TFS002/ 000 078 002 65535 65535 |
| 008 000 /TFS411/ 000 078 141 65535 65535 |
| 009 000 /TFS412/ 000 078 142 65535 65535 |
| 010 000 /TFS999/ 000 073 255 65535 65535 |
|
|
|
|
| Example of TRAFFIC report |
| ~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| 001 TFS000 |
|
|
| 13 10 1978 |
| 10 30 00 |
|
|
| 001 TFS102 |
|
|
| 00 0000157 00100 |
|
|
| 001 TFS102 |
|
|
| 01 0000194 00100 |
|
|
| 001 TFS102 |
|
|
| 02 0000194 00100 |
|
|
| . |
| . |
| . |
|
|
| 001 TFS001 |
|
|
| 00 TERM 00000 0000012 00023 00000 0000157 00161 |
| 01 TERM 00000 0000028 00018 00000 0000256 00157 |
| 02 TERM 00000 0000015 00019 00000 0000194 00134 |
| 06 CONF 00000 0000000 00000 00000 0000001 00003 |
| 07 TDS 00000 0000000 00000 00000 0000000 00000 |
| . |
| . |
| . |
|
|
|
|
|
|
| ************************************************************************ |
| ---------------- Northern Telecom SP-1 PABX Switch --------------------- |
| ************************************************************************ |
|
|
|
|
| Example of RMT data |
| ~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 013 VARIABLE LOWER: 00000 UPPER: 00042 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| -------------------------------------------------------------------------- |
| 001 001 /JAN/ 002 073 255 65535 65535 |
| 002 001 /FEB/ 002 073 255 65535 65536 |
| 003 001 /MAR/ 002 073 255 65535 65535 |
| 004 001 /APR/ 002 073 255 65535 65535 |
| 005 001 /MAY/ 002 073 255 65535 65535 |
| 006 001 /JUN/ 002 073 255 65535 65535 |
| 007 001 /JUL/ 002 073 255 65535 65535 |
| 008 001 /AUG/ 002 073 255 65535 65535 |
| 009 001 /SEP/ 002 073 255 65535 65535 |
| 010 001 /OCT/ 002 073 255 65535 65535 |
| 011 001 /NOV/ 002 073 255 65535 65535 |
| 012 001 /DEC/ 002 073 255 65535 65535 |
| 013 002 /19/ 000 075 054 65535 65535 |
| . |
| . |
| . |
|
|
| Example of TRAFFIC report |
| ~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
|
|
| 0067 OPR MEA 00315 013077 18 - 200SUS |
|
|
| LIN# 0 78 |
| 2 2 8 0 0 32 0 36 0 2 82 |
|
|
| LIN# 1 8 |
| 0 0 8 0 0 32 0 0 32 2 0 |
|
|
|
|
| WED 11 SEPT 1980 112777 |
|
|
| 572 415 23 3 46 160 1992 0 |
| 0 516 0 0 22 1 2180 0 |
|
|
| 0055 OPR MEA 045331 112044 |
|
|
| 2420 1713 101 10 327 628 4512 8512 0 |
|
|
| WED 11 SEPT 1980 1:06:27 1606CLS3 |
|
|
|
|
| . |
| . |
| . |
|
|
|
|
| *********************************************************************** |
| --------------- Stromberg Carlson DCO Switch (!!) --------------------- |
| *********************************************************************** |
|
|
| Example of RMT data |
| ~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 006 VARIABLE LOWER: 00000 UPPER: 00837 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| -------------------------------------------------------------------------- |
| 001 000 /COMPLETION/ 000 084 255 65535 65535 |
| 002 000 /ROW/ 001 077 001 00100 02039 |
| 003 001 /END OF TMR/ 000 073 255 65535 65535 |
| 004 001 /***/ 002 073 255 65535 65535 |
| 005 002 /^M/ 001 066 001 65535 65535 |
|
|
|
|
| Example of a TRAFFIC report |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| SITE:ACD,INC. GROUP: 1 BUFFER:ACTIVE |
| COLLECTION TIME: 08:00:00 05/01/79 |
| COMPLETION TIME: 08:01:05 05/01/79 |
|
|
| ROW ODD3S ODTNP |
| 0 1 2 |
| 1 |
| OLOSZ OLMAT ORVEC |
| 2 3 2 1 |
| OLOTB OLOTL OLOTP OLMDS OLMBY |
| 3 7 2 1 8 3 |
|
|
| 4 |
|
|
| 5 |
|
|
| ... |
| . |
| . |
| . |
| . |
|
|
|
|
| *********************************************************************** |
| -------------- TRW Vidar ITS 4/5 and ITS 5 Switches ------------------- |
| *********************************************************************** |
|
|
|
|
|
|
| Example of RMT data |
| ~~~~~~~~~~~~~~~~~~ |
|
|
|
|
| ACTION IN LINE 006 VARIABLE LOWER: 00000 UPPER: 00837 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| --------------------------------------------------------------------------- |
| 001 000 /ITD REPORT/ 000 073 255 65535 65535 |
| 002 000 / TO / 000 072 001 65535 65535 |
| 003 000 /SYSTEM/ 000 078 002 65535 65535 |
| 004 000 /GRADE/ 000 078 004 65535 65535 |
| 005 000 /SEPAR/ 000 073 004 65535 65535 |
| 006 000 /END/ 000 004 255 65535 65535 |
|
|
|
|
| Example of TRAFFIC report |
| ~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| TIMED ITS REPORT ADAM FROM 08-18-86 13:01:31 TO 08-18-86 14:00:28 |
| CLEARING COUNTERS |
|
|
| GROUP TOTALS |
|
|
| NAME TYPE ATT COM XCS AVH OFL |
|
|
| LSSO ORIG 131 93 1671 13 0 |
| LSSO TERM 129 98 1729 13 0 |
| LSS1 ORIG 159 111 3093 19 0 |
| LSS1 TERM 114 97 2793 25 0 |
| LSS2 ORIG |
| . |
| . |
| . |
| . |
|
|
|
|
| ********************************************************************* |
| ------------- Western Electric ESS 5 Switch ------------------------- |
| ********************************************************************* |
|
|
| Example of RMT data |
| ~~~~~~~~~~~~~~~~~~ |
|
|
| ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPPER: 00100 |
|
|
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING |
| PHASE PHASE REGISTER REGISTER |
| ---------------------------------------------------------------------------- |
| 001 000 /S570/ 001 075 255 65535 65535 |
| 002 001 /TION 1:/ 002 078 001 65535 65535 |
| 003 002 /TION 3:/ 003 078 002 65535 65535 |
|
|
| Example of TRAFFIC report |
| ~~~~~~~~~~~~~~~~~~~~~~~~ |
|
|
| S570-108396613 86-05-13 12:01:22 12430 |
| OP TRFC30 VLD |
| TIME: 12:0:27 |
|
|
| SECTION 1: VALIDITY |
|
|
| PROC DATLOS SCN10 SCN100 |
| 0 VALID 0 18 |
| 7 VALID 180 18 |
| 10 VALID 180 19 |
| 9 VALID 180 18 |
| 2 VALID 180 18 |
| 6 VALID 180 18 |
| 4 VALID 180 18 |
| 3 VALID 180 18 |
| 8 VALID 180 18 |
| 5 VALID 180 18 |
| 1 VALID 180 18 |
| 11 VALID 180 18 |
|
|
|
|
| S570-108396613 86-05-13 12:01:24 12431 |
| OP TRFC30 OFC |
| TIME 12:0:27 |
|
|
| SECTION 3: OFFICE TOTALS |
|
|
| DPORQ = 46 TTPRQ = 693 DPINRQ = 1226 |
| MFINRQ= 9577 CDIRR = 58 TCBUSY = 11 |
| . |
| . |
| . |
| . |
| . |
|
|
|
|
|
|
| ---------------------------------------------------------------------------- |
|
|